Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers

被引:20
|
作者
Kwon, Sun Il [1 ]
Ferri, AlessandroY [2 ]
Gola, Alberto [2 ]
Berg, Eric [1 ]
Piemonte, Claudio [2 ]
Cherry, Simon R. [1 ]
Roncali, Emilie [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Fdn Bruno Kessler, Via Sommarive 18, Trento, Italy
关键词
positron emission tomography; depth-of-interaction; time-of-flight; phosphor coating; silicon photomultiplier; coincidence timing resolution;
D O I
10.1117/1.JMI.3.4.043501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Current research in the field of positron emission tomography (PET) focuses on improving the sensitivity of the scanner with thicker detectors, extended axial field-of-view, and time-of-flight (TOF) capability. These create the need for depth-of-interaction (DOI) encoding to correct parallax errors. We have proposed a method to encode DOI using phosphor-coated crystals. Our initial work using photomultiplier tubes (PMTs) demonstrated the possibilities of the proposed method, however, a major limitation of PMTs for this application is poor quantum efficiency in yellow light, corresponding to the wavelengths of the converted light by the phosphor coating. In contrast, the red-green-blue-high-density (RGB-HD) silicon photomultipliers (SiPMs) have a high photon detection efficiency across the visible spectrum. Excellent coincidence resolving time (CRT; <210 ps) was obtained by coupling RGB-HD SiPMs and 3 x 3 x 20 mm(3) lutetium fine silicate crystals coated on a third of one of their lateral sides. Events were classified in three DOI bins (similar to 6.7-mm width) with an average sensitivity of 83.1%. A CRT of similar to 200 ps combined with robust DOI encoding is a marked improvement in the phosphor-coated approach that we pioneered. For the first time, we read out these crystals with SiPMs and clearly demonstrated the potential of the RGB-HD SiPMs for this TOF-DOI PET detector. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:7
相关论文
共 3 条
  • [1] Characterization of a scintillating mini-detector for time-of-flight positron emission tomography with depth-of-interaction
    Cosentino, Luigi
    Finocchiaro, Paolo
    Pappalardo, Alfio
    Garibaldi, Franco
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (08):
  • [2] A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography
    Berg, Eric
    Roncali, Emilie
    Kapusta, Maciej
    Du, Junwei
    Cherry, Simon R.
    [J]. MEDICAL PHYSICS, 2016, 43 (02) : 939 - 950
  • [3] Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout
    Seo, Minjee
    Park, Haewook
    Lee, Seungeun
    Ko, Guen Bae
    Lee, Jae Sung
    [J]. MEDICAL PHYSICS, 2023, 50 (07) : 4112 - 4121