Addressing spatiotemporal distortion of high-speed tissue motion in B-mode ultrasound

被引:0
|
作者
Mallory, Ann [1 ,2 ]
Donnelly, Bruce [3 ,6 ]
Liu, Jun [4 ]
Bahner, David [5 ]
Moorhouse, Kevin [6 ]
Dupaix, Rebecca [2 ]
机构
[1] Transportat Res Ctr Inc, POB B-37,10820 State Route 347, East Liberty, OH 43319 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, E310 Scott Lab, Columbus, OH 43210 USA
[3] Biomech Res Associates, 22 West Lincoln Ave, Delaware, OH 43015 USA
[4] Ohio State Univ, Dept Biomed Engn, 1080 Carmack Rd, Columbus, OH 43210 USA
[5] Ohio State Univ, Med Ctr, 460 West 10th Ave, Columbus, OH 43210 USA
[6] Natl Highway Traff Safety Adm, POB B-37,10820 State Route 347, East Liberty, OH 43319 USA
来源
关键词
ultrasound; high-frequency; B-mode; spatiotemporal distortion; correction; rolling shutter; injury biomechanics;
D O I
10.1088/2057-1976/aad925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The sequential excitation of transducer elements in linear ultrasound arrays can produce distorted images in B-mode since the A-lines in an image frame are not captured at the same time. If the imaged tissue is moving laterally during image acquisition, substantial distortion can occur and lead to errors in tissue displacement and velocity measurements, particularly for high-speed tissue motion such as in injury biomechanics tests. A method for correcting for this distortion in tracked time-series displacement data was developed for systems in which each A-line of the image is completed at a time proportional to its lateral position across the transducer linear array. The proposed method involves estimating more precisely the time at which each point in the image was captured, rather than relying on the time elapsed between image frames to estimate timing. The developed method was evaluated using results from motion tests of human dura imaged using a Vevo 2100 Imaging System at a frame rate of 865 frames per second. At tissue speeds ranging from 0.2 m s(-)1 to 2.3 m s(-1), tracking of tissue displacement without correction resulted in mean displacement measurement error of 17%. Correction using proposed methods reduced error to a mean of 2%. This correction concept has the potential to improve the accuracy of velocity or displacement measurements in any B-mode imaging application where tissue velocity is high relative to ultrasound sweep velocity including in injury biomechanics and cardiac biomechanics research.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] CLINICAL APPLICATION OF HIGH-SPEED B-MODE ECHOCARDIOGRAPHY
    KAMBE, T
    NISHIMURA, K
    HIBI, N
    SAKAKIBARA, T
    KATO, T
    FUKUI, Y
    ARAKAWA, T
    TATEMATSU, H
    MIWA, A
    TADA, H
    SAKAMOTO, N
    JOURNAL OF CLINICAL ULTRASOUND, 1977, 5 (03) : 202 - 207
  • [2] Bimodal myocardial motion analysis from B-MODE and tissue doppler ultrasound
    Sühling, M
    Arigovindan, M
    Jansen, C
    Hunziker, P
    Unser, M
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 308 - 311
  • [3] Deep CNN-based ultrasound super-resolution for high-speed high-resolution B-mode imaging
    Choi, Woosuk
    Kim, Mina
    Lee, Jae Hak
    Kim, Jungho
    Ra, Jong Beom
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [4] Low-Cost, High-Speed Back-End Processing System for High-Frequency Ultrasound B-Mode Imaging
    Chang, Jin Ho
    Sun, Lei
    Yen, Jesse T.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (07) : 1490 - 1497
  • [5] Fast B-Mode ultrasound image simulation of deformed tissue
    Goksel, Orcun
    Salcudean, Septimiu E.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 87 - 90
  • [6] Carotid Wall Motion Analysis Based on B-Mode Ultrasound Images
    Hopkins, Warren
    Gao, Hao
    Das, Saroj
    Long, Quan
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 871 - 874
  • [7] Motion correction for radiation therapy of prostate using B-mode Ultrasound
    Hummel, Johann
    Figl, Michael
    Schmidbauer, Joerg
    Tinzl, Martina
    Bergmann, Helmar
    Birkfellner, Wolfgang
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [8] SPECKLE IN ULTRASOUND B-MODE SCANS
    BURCKHARDT, CB
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01): : 1 - 6
  • [9] Perspectives of B-mode transcranial ultrasound
    Berg, D
    Becker, G
    NEUROIMAGE, 2002, 15 (03) : 463 - 473
  • [10] B-MODE ULTRASOUND CHARACTERIZATION OF ATHEROSCLEROSIS
    MERCURI, M
    BOND, MG
    JOURNAL OF CARDIOVASCULAR TECHNOLOGY, 1992, 10 (04): : 277 - 291