REFERENCE NEUTRON FIELDS WITH ENERGIES UP TO 70-MEV FOR THE CALIBRATION OF RADIATION PROTECTION INSTRUMENTS

被引:0
|
作者
SCHUHMACHER, H
ALBERTS, WG
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The potential use of nearly monoenergetic radiation fields for the calibration of radiation protection instruments for neutron energies up to about 70 MeV is discussed. The ambiguous situation with respect to the conversion coefficients for operational dose equivalent quantities in this energy region is reviewed. The results of such a calibration are presented using the example of a TEPC evaluated for dose equivalent.
引用
收藏
页码:287 / 290
页数:4
相关论文
共 50 条
  • [1] DOSIMETRIC PARAMETERS OF SIMPLE NEUTRON+ GAMMA-FIELDS FOR CALIBRATION OF RADIATION PROTECTION INSTRUMENTS
    JOZEFOWICZ, K
    GOLNIK, N
    ZIELCZYNSKI, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 139 - 142
  • [2] Quasi-monoenergetic reference neutron beams with energies from 25 MeV to 70 MeV
    Schumacher, H
    Brede, HJ
    Dangendorf, V
    Kuhfuss, M
    Meulders, JP
    Newhauser, WD
    Nolte, R
    Schrewe, UJ
    [J]. INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 59, PT 1 AND 2, 1997, 59 : 388 - 392
  • [3] CALIBRATION OF NEUTRON INSTRUMENTS AND DOSIMETERS AT INTERMEDIATE ENERGIES
    HARRISON, KG
    HARVEY, JR
    BOOT, SJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 148 (03): : 511 - 520
  • [4] RADIATION SHIELDING CALCULATIONS FOR A 70-MEV TO 250-MEV PROTON THERAPY FACILITY
    HAGAN, WK
    COLBORN, BL
    ARMSTRONG, TW
    ALLEN, M
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 1988, 98 (03) : 272 - 278
  • [5] NEUTRON ASYMMETRY MEASUREMENTS IN THE DEUTERON PHOTO-DISINTEGRATION BETWEEN 10-MEV AND 70-MEV
    DELBIANCO, W
    FEDERICI, L
    GIORDANO, G
    MATONE, G
    PASQUARIELLO, G
    PICOZZA, P
    CALOI, R
    CASANO, L
    DEPASCALE, MP
    INGROSSO, L
    MATTIOLI, M
    POLDI, E
    SCHAERF, C
    PELFER, P
    PROSPERI, D
    FRULLANI, S
    GIROLAMI, B
    JEREMIE, H
    [J]. PHYSICAL REVIEW LETTERS, 1981, 47 (16) : 1118 - 1120
  • [6] THERMAL-NEUTRON IRRADIATION FIELD FOR ROUTINE CALIBRATION OF RADIATION PROTECTION INSTRUMENTS
    ASANO, Y
    UESAWA, T
    MINAMI, K
    [J]. HEALTH PHYSICS, 1985, 49 (02): : 375 - 375
  • [7] Radiation damages of GaAlAs LEDs by 70-MeV proton and 2-MeV electron irradiation
    Ohyama, H.
    Shitogiden, H.
    Takakura, K.
    Shigaki, K.
    Kuboyama, S.
    Kamesawa, C.
    Simoen, E.
    Claeys, C.
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2008, 19 (02) : 171 - 173
  • [8] Radiation damages of GaAlAs LEDs by 70-MeV proton and 2-MeV electron irradiation
    H. Ohyama
    H. Shitogiden
    K. Takakura
    K. Shigaki
    S. Kuboyama
    C. Kamesawa
    E. Simoen
    C. Claeys
    [J]. Journal of Materials Science: Materials in Electronics, 2008, 19 : 171 - 173
  • [9] RADIATION PROTECTION IN NEUTRON FIELDS
    DORSCHEL, B
    [J]. KERNENERGIE, 1983, 26 (08): : 315 - 318
  • [10] Intensity and spectra of a white light neutron source produced by a 70-MeV proton accelerator
    Shen, QB
    [J]. NUCLEAR TECHNOLOGY, 2000, 132 (01) : 61 - 65