Domestic Microwave Versus Conventional Tissue Processing: A Quantitative and Qualitative Analysis

被引:2
|
作者
Devi, Bhuvanamha R. [1 ]
Subhashree, A. R. [1 ]
Parameaswari, P. J. [2 ]
Parijatham, B. O. [1 ]
机构
[1] Sree Balaji Med Coll & Hosp, Dept Pathol, 7 Works Rd, Chennai 600044, Tamil Nadu, India
[2] Sree Balaji Med Coll & Hosp, Dept Biostat, Chennai, Tamil Nadu, India
关键词
Domestic microwave oven; Tissue processing;
D O I
10.7860/JCDR/2013/5630.2953
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microwave irradiation has been tried as a replacement for the conventional tissue processing technique in histopathology laboratories for quite some time. Studies have shown that Domestic Microwave Tissue Processing (DMWTP) provides a faster delivery of the tissue sections with a morphology which is similar to that which is seen Conventional Tissue Processing (CTP). But many laboratories still confine the domestic microwave tissue processing method only to the handle selected specimens, for which urgent reports are needed. One of the probable reasons is that, understanding about the number of tissue sections which can be processed using a microwave oven at a time, with the appropriate quality, still remains unclear. Aim: The aim of this study was to quantitatively analyze the optimum number of samples that a domestic microwave could process at a time, as well as to qualitatively analyze the morphological outcome of those tissue sections with that of conventional processing. Materials and Methods: This study was approved by the research and ethical committee of Sree Balaji Medical College and Hospital. A total of 135 paired tissue sections were included in the study. Ten tissue sections (which are mentioned hereafter as A10) were processed in a domestic microwave and their paired 10 tissues were processed by a conventional method. Subsequently, the number of tissues which was to be processed was increased to B15, C20, D25, E30 and F35, after ascertaining that the morphological qualities of the previously processed tissue sections were satisfactory. Sections of 4 aem thickness were taken and they were stained by the Haematoxylin and Eosin method. The slides of the tissues which were processed by the microwave method and the conventional method were randomly numbered, for a blind study, which were independently evaluated by two observers. The qualities of slides were assessed, based on 4 parameters: the cytoplasmic details, the nuclear details, the tissue architecture and the staining characteristics. The statistical analysis was done by using SPSS 15.0. Results: The morphological outcomes (quality) of the DMWTPs were comparable to that of the CTPs, when the sample load (quantity) in the microwave oven was up to 25 samples. Conclusion: Domestic microwave processing can be effectively used in laboratories with a maximum sample size of 25 samples per load. This has the advantage of being rapid, with its morphological quality being identical to that of conventional processing.
引用
收藏
页码:835 / 839
页数:5
相关论文
共 50 条
  • [1] A Comparative Study on Microwave Tissue Processing and Conventional Tissue Processing
    Mukunda, Archana
    Shreedhar, Balasundhari
    Narayan, T., V
    Shashidhara, R.
    Mohanty, Leeky
    Shenoy, Sadhana
    [J]. ORAL & MAXILLOFACIAL PATHOLOGY JOURNAL, 2022, 13 (01) : 11 - 17
  • [2] Effect of Conventional and Microwave Tissue Processing Technique on DNA Integrity: A Comparative Molecular Analysis
    Dwivedi, Dhara
    Kasetty, Sowmya
    Tijare, Manisha S.
    Kallianpur, Shreenivas
    Prabhakar, Nitin
    Ragavendra, Raju T.
    Desai, Ami
    [J]. ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2018, 28 (05) : 615 - 624
  • [3] Qualitative and quantitative aspects of microwave thermal analysis
    Parkes, GMB
    Barnes, PA
    Bond, G
    Charsley, EL
    [J]. THERMOCHIMICA ACTA, 2000, 356 (1-2) : 85 - 96
  • [4] Comparative Analysis of Immunohistochemistry of Hormone Receptors in Breast Cancer by Conventional and Microwave Tissue Processing Methods
    Ramakrishnan, Janaky
    Sideeque, Asiq N.
    Khader, Reslin A.
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : EC34 - EC38
  • [5] Qualitative versus quantitative risk analysis and modelling
    Vose, D
    [J]. RISK ANALYSIS IN AQUATIC ANIMAL HEALTH, PROCEEDINGS, 2001, : 19 - 26
  • [6] Microwave versus conventional porcelain firing: Colour analysis
    Santos, T.
    Hennetier, L.
    Costa, V. A. F.
    Costa, L. C.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2022, 275
  • [7] Qualitative and Quantitative Analysis of Sugar, Proteins and Lipids in Domestic Sewage
    Chiu M.-C.
    Chen C.-J.
    Chen H.-Y.
    Chen T.-Y.
    Lee C.-H.
    Lin C.-F.
    [J]. Journal of the Chinese Institute of Civil and Hydraulic Engineering, 2020, 32 (01): : 91 - 99
  • [8] Evaluation of shear wave elastography for differential diagnosis of breast lesions: A new qualitative analysis versus conventional quantitative analysis
    Ren, Wei-Wei
    Li, Xiao-Long
    Wang, Dan
    Liu, Bo-Ji
    Zhao, Chong-Ke
    Xu, Hui-Xiong
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2018, 69 (03) : 425 - 436
  • [9] Diagnostic Tissue Preparation: Further Assessment of Microwave-Based Compared to Conventional Tissue Processing
    Blieden, C. R.
    Reyes, M. C.
    Garcia-Buitrago, M. T.
    Nose, V.
    Vernon, S.
    Morales, A. R.
    [J]. LABORATORY INVESTIGATION, 2012, 92 : 511A - 511A
  • [10] Diagnostic Tissue Preparation: Further Assessment of Microwave-Based Compared to Conventional Tissue Processing
    Blieden, C. R.
    Reyes, M. C.
    Garcia-Buitrago, M. T.
    Nose, V.
    Vernon, S.
    Morales, A. R.
    [J]. MODERN PATHOLOGY, 2012, 25 : 511A - 511A