VISUALIZATION AND MEASUREMENT OF FLOW VELOCITY AND FLOW RESERVE IN CORONARY-ARTERY BYPASS GRAFTS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY

被引:0
|
作者
ANTHONY, P [1 ]
TAK, T [1 ]
HURWITZ, R [1 ]
CURRY, S [1 ]
PENDERGAST, T [1 ]
机构
[1] UNIV SO CALIF,SCH MED,LOS ANGELES,CA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:2554 / 2554
页数:1
相关论文
共 50 条
  • [1] Visualization and measurement of flow velocity and flow reserve in aortocoronary saphenous vein bypass grafts by transesophageal echocardiography
    Chandraratna, PAN
    Tak, T
    Ismail, Y
    Curry, S
    Hurvitz, R
    Prendergast, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (07): : 955 - &
  • [2] COMPARISON OF FLOW VELOCITY IN THE LEFT ANTERIOR DESCENDING CORONARY-ARTERY AND CORONARY FLOW RESERVE, BY INTRACORONARY DOPPLER FLOW WIRE AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    THAKER, KB
    KAWANISHI, D
    NARANG, YK
    RASHTIAN, M
    MEHRA, A
    ANTHONY, P
    CHANDRARATNA, N
    CIRCULATION, 1994, 90 (04) : 276 - 276
  • [3] Comparison of intracoronary Doppler guide wire and transesophageal echocardiography in measurement of flow velocity and coronary flow reserve in the left anterior descending coronary artery
    Gadallah, S
    Thaker, KB
    Kawanishi, D
    Mehra, A
    Lau, S
    Rashtian, M
    Chandraratna, PAN
    AMERICAN HEART JOURNAL, 1998, 135 (01) : 38 - 42
  • [4] Measurement of coronary sinus flow using transesophageal echocardiography undergoing coronary artery bypass grafting
    Toyota, S
    Amaki, Y
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [5] POSTOPERATIVE ASSESSMENT OF FLOW RESERVE IN CORONARY-ARTERY BYPASS GRAFTS USING INTRAVENOUS DIPYRIDAMOLE
    PORT, S
    LASSAR, TA
    PATEL, S
    KAMATH, ML
    SCHMIDT, DH
    CIRCULATION, 1983, 68 (04) : 261 - 261
  • [6] Measurement of coronary sinus flow using transesophageal echocardiography in patients undergoing coronary artery bypass grafting
    Toyota, S
    Amaki, Y
    JOURNAL OF CLINICAL ANESTHESIA, 2000, 12 (04) : 270 - 272
  • [7] Determination of coronary flow measurements by transesophageal echocardiography: Dependence of flow velocity reserve on the location of stenosis
    Hutchison, SJ
    Soldo, SJ
    Gadallah, S
    Kawanishi, DT
    Chandraratna, PAN
    AMERICAN HEART JOURNAL, 1997, 133 (01) : 44 - 52
  • [8] DOPPLER FLOW MEASUREMENT IN CORONARY-ARTERY BYPASS GRAFTS AND EARLY POSTOPERATIVE CLINICAL OUTCOME
    LOUAGIE, YAG
    HAXHE, JP
    JAMART, J
    BUCHE, M
    SCHOEVAERDTS, JC
    THORACIC AND CARDIOVASCULAR SURGEON, 1994, 42 (03): : 175 - 181
  • [9] MEASUREMENT OF CORONARY-ARTERY FLOW RESERVE BY MAGNETIC-RESONANCE VELOCITY MAPPING IN THE AORTA
    BOGREN, HG
    BUONOCORE, MH
    LANCET, 1993, 342 (8876): : 899 - 900
  • [10] Coronary flow velocity reserve measurement in the right coronary artery with contrast enhanced transthoracic Doppler echocardiography
    Watanabe, H
    Hirata, K
    Muro, T
    Shimada, K
    Kobayashi, Y
    Ehara, S
    Otsuka, R
    Ujino, K
    Teragaki, M
    Yoshikawa, J
    CIRCULATION, 2000, 102 (18) : 541 - 542