摘要
This paper deals with the simulation of a Distribution Static Compensator (DSTATCOM) for power quality improvement in a four-wire electric distribution system. A three-phase Insulated Gate Bipolar Transistor (IGBT)-based Current-Controlled Voltage Source Inverter (CC-VSI) with a DC bus capacitor is used as a DSTATCOM. The DSTATCOM improves the supply power factor, eliminates harmonics, provides load balancing and improves the load terminal voltage at the Point of Common Coupling (PCC). The DC bus voltage of the DSTATCOM and three-phase voltages at PCC are used as feedback signals for PI controllers. The control algorithm of the DSTATCOM provides three-phase reference supply currents. A carrierless hysteresis current controller is employed over the reference and sensed supply currents to generate gating pulses for the IGBTs of DSTATCOM. Simulation is carried out in the MATLAB environment using Simulink and Power System (PSB) toolboxes. Results are presented and discussed, which demonstrate power quality improvement capability of DSTATCOM system.
引用
收藏
页码:401 / 416
页数:16
相关论文
共 50 条
  • [1] A three-phase four-wire DSTATCOM for power quality improvement
    Singh, Bhim
    Jayaprakash, P.
    Kothari, D. P.
    JOURNAL OF POWER ELECTRONICS, 2008, 8 (03) : 259 - 267
  • [2] Mitigation of Power Quality Issues in Three-Phase Four-Wire Distribution System Employing Four-Leg DSTATCOM
    Sundarabalan, C. K.
    Selvi, K.
    Vaz, P. Shirley
    POWER ELECTRONICS AND RENEWABLE ENERGY SYSTEMS, 2015, 326 : 753 - 760
  • [3] Star/Hexagon Transformer Based Three-Phase Four-Wire DSTATCOM for Power Quality Improvement
    Singh, Bhim
    Pychadathil, Jayaprakash
    Kothari, Dwarkadas Pralhaddas
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2008, 9 (06):
  • [4] DSP Based Implementation of a Three-Phase Four-Wire DSTATCOM for Voltage Regulation and Power Quality Improvement
    Jayaprakash, P.
    Singh, Bhim
    Kothari, D. P.
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 3484 - +
  • [5] Power Quality Improvement in three-phase four-wire Distribution systems by DSTATCOM and using adaptive hysteresis band current controller
    Rohani, A.
    Joorabian, M.
    Rahimi, S.
    2014 22ND IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2014, : 616 - 621
  • [6] Comparison of control strategies for DSTATCOM in three-phase, four-wire distribution system for power quality improvement under various source voltage and load conditions
    Zaveri, Tejas
    Bhalja, Bhavesh
    Zaveri, Naimish
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 43 (01) : 582 - 594
  • [7] Adaptive Control Algorithm for DSTATCOM in three phase four wire distribution systems for Power Quality Improvement
    Ram, Atma
    Sharma, Paras Ram
    Ahuja, Rajesh Kr
    2019 3RD INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION & POWER ENGINEERING (RDCAPE), 2019, : 622 - 627
  • [8] Three-Phase Four-Wire DSTATCOM with H-Bridge VSC and Star/Delta Transformer for Power Quality Improvement
    Singh, Bhim
    Jayaprakash, P.
    Kothari, D. P.
    PROCEEDINGS OF THE INDICON 2008 IEEEE CONFERENCE & EXHIBITION ON CONTROL, COMMUNICATIONS AND AUTOMATION, VOL II, 2008, : 412 - +
  • [9] DSTATCOM with Reduced Switches Using Two-Leg VSC and a Zig-Zag Transformer for Power Quality Improvement in Three-Phase Four-Wire Distribution System
    Singh, Bhim
    Jayaprakash, P.
    Somayajulu, T. R.
    Kothari, D. P.
    2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 97 - +
  • [10] Enhancement of Power Quality with ANFIS Controlled DSTATCOM in Four Wire Three Phase Distribution System
    Murali, M. R. V.
    Srinivasu, K.
    Rao, L. V. Narasimha
    2016 BIENNIAL INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS: TOWARDS SUSTAINABLE ENERGY (PESTSE), 2016,