Enhanced conductivity detection of common inorganic anions in electrostatic ion chromatography using water eluent

被引:2
|
作者
Kozaki, Daisuke [1 ]
Shi, Chao-Hong [1 ]
Tanaka, Kazuhiko [1 ,2 ]
Nakatani, Nobutake [3 ]
机构
[1] Hiroshima Univ, Int Dev & Cooperat, Higashihiroshima 7398529, Japan
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
[3] Rakuno Gakuen Univ, Fac Environm Syst, Ebetsu, Hokkaido 0698501, Japan
基金
日本学术振兴会;
关键词
electrostatic ion chromatography; EIC; common anions; conductivity enhancement; water eluent;
D O I
10.3724/SP.J.1123.2011.12049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To enhance the conductivity detection sensitivity of common anions Na-anions in electrostatic ion chromatography EIC by elution with water a conductivity enhancement column packed with strong acid cation exchange resin in the H-form was inserted between an octadecyl silane ODS -silica separation column modified with zwitterionic surfactant CHAPS 3- 3-cholamidopropyl -dimethylammonio propanesulfonate and a conductivity detector. Specifically the Na-anion pairing is converted to H-anion pairing after the EIC separation and then detected sensitively by the conductivity detector. The effects of conductivity enhancement and suppression in the EIC by the enhanced conductivity detection were characterized for the common strong acid anions such as SO4(2)(-) Cl- NO3- I- and CIO4- and weak acid anions such as F- NO2- HCOO- CH3COO- and HCO3-. For the conductivity enhancement effect in the EIC it is found that the conductivity of measured for all strong acid anions Na-anions was enhanced according to the theoretical conductivity predicted for H-anions and that of the measured for weak acid anions was suppressed depending on their pK(a) of H-anions. For the calibration linearity in the EIC the strong acid anions were linear r(2) = 0.99 -1. 00 because the degree of dissociation is almost 1.0 over all the concentration range and that of the weak acid anions was non-linear because the degree of dissociation decreased by increasing the concentration of the weak acid anions. In conclusion the EIC by enhanced conductivity detection was recognized to be useful only for the strong acid anions in terms of conductivity detection and calibration linearity.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 50 条
  • [1] Determination of Tetrafluoroborate and Common Inorganic Anions by Ion Chromatography with Direct Conductivity Detection
    Zhou Shuang
    Yu Hong
    Al Hong-Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (11) : 1521 - 1525
  • [2] 2,6-Pyridinedicarboxylic acid as an eluent for UV and conductivity detection of inorganic anions, magnesium and calcium in water by ion chromatography
    Department of Botany, University of Western Australia, Nedlands, WA 6007, Australia
    Chromatographia, 9-10 (496-502):
  • [3] 2,6-Pyridinedicarboxylic acid as an eluent for UV and conductivity detection of inorganic anions, magnesium and calcium in water by ion chromatography
    Z. L. Chen
    M. A. Adams
    Chromatographia, 1999, 49 : 496 - 502
  • [4] 2,6-pyridinedicarboxylic acid as an eluent for UV and conductivity detection of inorganic anions, magnesium and calcium in water by ion chromatography
    Chen, ZL
    Adams, MA
    CHROMATOGRAPHIA, 1999, 49 (9-10) : 496 - 502
  • [5] Simultaneous separation of inorganic anions and cations using binary eluent by ion chromatography with indirect photometric detection
    Hou, JG
    Bian, HJ
    Gao, JZ
    Kang, JW
    CHROMATOGRAPHIA, 1996, 43 (9-10) : 473 - 476
  • [6] Suppressed electrostatic ion chromatography with tetraborate as eluent and its application to the determination of inorganic anions in snow and rainwater
    Hu, WZ
    Tanaka, K
    Haddad, PR
    Hasebe, K
    JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) : 161 - 165
  • [7] Electrostatic Ion Chromatography of Common Anions and Cations with a Zwitterionic Surfactant-Modified Silica-C18 Column Using Water Eluent
    Masuda, Wakako
    Kozaki, Daisuke
    Nakatani, Nobutake
    Goto, Ryozo
    Mori, Masanobu
    Fugetsu, Bunshi
    Tanaka, Kazuhiko
    BUNSEKI KAGAKU, 2009, 58 (04) : 311 - 315
  • [8] Determination of Inorganic Cations and Anions in Chitooligosaccharides by Ion Chromatography with Conductivity Detection
    Cao, Lidong
    Li, Xiuhuan
    Fan, Li
    Zheng, Li
    Wu, Miaomiao
    Zhang, Shanxue
    Huang, Qiliang
    MARINE DRUGS, 2017, 15 (02):
  • [9] SIMULTANEOUS DETERMINATION OF TOTAL CARBONATE AND COMMON INORGANIC ANIONS IN ENVIRONMENTAL WATERS BY ION CHROMATOGRAPHY WITH INDIRECT UV-PHOTOMETRIC DETECTION USING BENZENEPOLYCARBOXYLATE ELUENT
    OHTA, K
    TANAKA, K
    NIPPON KAGAKU KAISHI, 1995, (11) : 895 - 899
  • [10] POTENTIOMETRIC DETECTION OF CARBOXYLIC-ACIDS AND INORGANIC ANIONS IN ION-EXCLUSION CHROMATOGRAPHY USING CAMPHORSULPHONIC ACID AS ELUENT
    GLOD, BK
    HADDAD, PR
    ALEXANDER, PW
    JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2): : 209 - 214