DEVELOPMENT OF A BIOTIN-STREPTAVIDIN-ENHANCED ENZYME-LINKED-IMMUNOSORBENT-ASSAY WHICH USES MONOCLONAL-ANTIBODIES FOR DETECTION OF GROUP-C ROTAVIRUSES

被引:7
|
作者
OJEH, CK [1 ]
TSUNEMITSU, H [1 ]
SIMKINS, RA [1 ]
SAIF, LJ [1 ]
机构
[1] OHIO STATE UNIV,OHIO AGR RES & DEV CTR,FOOD ANIM HLTH RES PROGRAM,WOOSTER,OH 44691
关键词
D O I
10.1128/JCM.30.7.1667-1673.1992
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A biotin-streptavidin-enhanced enzyme-linked immunosorbent assay (ELISA) which uses monoclonal antibodies (MAbs) for the detection of group C rotaviruses was developed. An assay in which plates were coated with three pooled MAbs and biotinylated polyclonal immunoglobulin G (IgG) (polyclonal antibody [PAb]) was used as the detector (MAb capture-PAb detector) was found to be the most sensitive and specific of the assays when it was compared with assays in which plates were coated with polyclonal antiserum and detection was done with either biotinylated polyclonal antiserum (PAb capture-PAb detector) or biotinylated pooled MAbs (PAb capture-MAb detector). The MAb capture-PAb detector ELISA detected 83% of samples confirmed to be positive for group C rotaviruses, whereas the PAb capture-PAb detector assay detected 63% of positive samples and the PAb capture-Mab detector assay detected 65% of positive samples. All three procedures detected both of the bovine and the two human group C rotaviruses, but none of the three procedures detected fecal samples containing group A and B rotaviruses or fecal samples negative for group C rotaviruses used in this study. The sensitivity of the MAb capture-PAb detector ELISA was determined by serially diluting fecal group C rotaviruses; antigens were detected in maximal positive dilution ranges of 1:1,000 to 1:3,000 for the samples tested. On the basis of the cell culture immunofluorescence assay infectivity titer of semipurified cell culture-passaged Cowden group C rotavirus, the sensitivity of the MAb capture-PAb detection ELISA for detection of homologous group C rotavirus was 53 fluorescent focus units per ml. Epitope mapping by use of the biotinylated MAbs in a competition assay suggested that our MAbs may bind to three different but overlapping epitopes. These results suggest that the MAb capture-PAb detector ELISA can be used to study the epidemiology of group C rotaviruses in humans and animals.
引用
收藏
页码:1667 / 1673
页数:7
相关论文
共 50 条
  • [1] DETECTION OF HUMAN GROUP-C ROTAVIRUSES BY AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING MONOCLONAL-ANTIBODIES
    FUJII, R
    KUZUYA, M
    HAMANO, M
    YAMADA, M
    YAMAZAKI, S
    JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (05) : 1307 - 1311
  • [2] SUBGROUP CLASSIFICATION OF PORCINE GROUP-A ROTAVIRUSES, USING MONOCLONAL-ANTIBODIES IN AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY
    KASSUBA, A
    SAIF, LJ
    GREENBERG, HB
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1990, 51 (06) : 938 - 944
  • [3] ASSAY FOR ANTIBODIES TO GROUP-C AND GROUP-G STREPTOCOCCAL CARBOHYDRATE BY ENZYME-LINKED-IMMUNOSORBENT-ASSAY
    AYOUB, EM
    HAWTHORNE, T
    MILLER, J
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1986, 107 (03): : 204 - 209
  • [4] Biotin-Streptavidin-enhanced Enzyme-Linked Immunosorbent Assay for the Determination of Parathion-Methyl in Vegetables
    Yuan, Lipeng
    Liu, Bo
    Yin, Kaidan
    Yang, Guandong
    Huang, Li
    Nie, Yehua
    ANALYTICAL LETTERS, 2013, 46 (07) : 1084 - 1096
  • [5] DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN-A BY SANDWICH ENZYME-LINKED-IMMUNOSORBENT-ASSAY WITH MONOCLONAL-ANTIBODIES
    SHINAGAWA, K
    SUZUKI, M
    MATSUSAKA, N
    SUGII, S
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1991, 53 (06): : 1093 - 1095
  • [6] MEASUREMENT OF STAPHYLOKINASE BY ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING MONOCLONAL-ANTIBODIES
    MIKE, A
    OHYA, Y
    OHWAKI, M
    SAKAI, M
    SAKO, T
    WATANABE, T
    YOKOKURA, T
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 1994, 17 (05) : 564 - 567
  • [7] ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR PANCREATIC COLIPASE USING MONOCLONAL-ANTIBODIES
    RATHELOT, J
    PINEL, G
    DELAFOURNIERE, L
    SARDA, L
    BOSCBIERNE, I
    DIGESTION, 1987, 38 (01) : 54 - 54
  • [8] AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR NITRATE REDUCTASE USING MONOCLONAL-ANTIBODIES
    WHITFORD, PN
    FIDO, RJ
    NOTTON, BA
    PHYTOCHEMISTRY, 1987, 26 (09) : 2467 - 2470
  • [9] DETECTION OF IMMUNOGLOBULIN BINDING-FACTOR BY ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING 2 MONOCLONAL-ANTIBODIES
    KAMADA, M
    MAEDA, N
    MAEGAWA, M
    MORI, H
    YAMAMOTO, S
    AONO, T
    MURAGUCHI, M
    OHMOTO, Y
    FUTAKI, S
    OGUSHI, F
    SONE, S
    KANAYAMA, H
    KAGAWA, S
    KOIDE, SS
    BIOCHEMISTRY AND MOLECULAR BIOLOGY INTERNATIONAL, 1994, 34 (04): : 837 - 844
  • [10] USE OF MONOCLONAL-ANTIBODIES FOR DETECTION OF INFECTIOUS PANCREATIC NECROSIS VIRUS BY THE ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA)
    DOMINGUEZ, J
    HEDRICK, RP
    SANCHEZVIZCAINO, JM
    DISEASES OF AQUATIC ORGANISMS, 1990, 8 (03) : 157 - 163