MR Imaging-Guided Partial Volume Correction of PET Data in PET/MR Imaging

被引:33
|
作者
Erlandsson, Kjell [1 ]
Dickson, John [2 ]
Arridge, Simon [3 ]
Atkinson, David [4 ]
Ourselin, Sebastien [5 ]
Hutton, Brian F. [1 ,6 ]
机构
[1] UCLH, Univ Coll London, Inst Nucl Med, Euston Rd T-5, London NW1 2BU, England
[2] Univ Coll London Hosp, Inst Nucl Med, Euston Rd T-5, London NW1 2BU, England
[3] UCL, Dept Comp Sci, Gower St, London WC1E 6BT, England
[4] UCL, Ctr Med Imaging, 250 Euston Rd, London NW1 2PG, England
[5] UCL, Ctr Med Imaging Comp, Gower St, London WC1E 6BT, England
[6] Univ Wollongong, Ctr Med Radiat Phys, Northfields Ave, Wollongong, NSW 2522, Australia
基金
英国工程与自然科学研究理事会;
关键词
Partial volume effects; Partial volume correction; PET/MR imaging; Quantification;
D O I
10.1016/j.cpet.2015.09.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial volume effects are caused by the limited spatial resolution of the PET system. There is increasing evidence that partial volume correction (PVC) is necessary to guarantee quantitative accuracy in PET; however, there is reluctance to apply PVC routinely in clinical practice, partly because of uncertainty regarding the method of choice. To perform accurate PVC, it is necessary to introduce information from high-resolution anatomic images, such as MR imaging. All the methods rely on accurate coregistration between the anatomic image and the PET image. PET/MR imaging offers clear advantages for PVC and can help alleviate the image registration issues.
引用
收藏
页码:161 / +
页数:18
相关论文
共 50 条
  • [1] MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging
    Izquierdo-Garcia, David
    Catana, Ciprian
    PET CLINICS, 2016, 11 (02) : 129 - +
  • [2] Tracer effect on partial volume correction of Brain PET/MR imaging
    Balci, E.
    Akdemir, U.
    Atay, L. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S20 - S20
  • [3] Evaluation of MR imaging-based partial volume correction methods for PET imaging
    Meltzer, CC
    Kinahan, P
    Greer, PJ
    Nichols, TE
    Price, JC
    RADIOLOGY, 1997, 205 : 1261 - 1261
  • [4] CORRECTION OF PET DATA FOR PARTIAL VOLUME EFFECTS IN HUMAN CEREBRAL-CORTEX BY MR IMAGING
    MELTZER, CC
    LEAL, JP
    MAYBERG, HS
    WAGNER, HN
    FROST, JJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 561 - 570
  • [5] Validations for MR-based partial volume correction for brain PET imaging
    Matsubara, Keisuke
    Ibaraki, Masanobu
    Maeda, Tetsuya
    Kinoshita, Toshibumi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [6] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [7] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 245 - +
  • [9] Multimodality Brain Tumor Imaging: MR Imaging, PET, and PET/MR Imaging
    Fink, James R.
    Muzi, Mark
    Peck, Melinda
    Krohn, Kenneth A.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (10) : 1554 - 1561
  • [10] Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
    Petibon, Yoann
    Guehl, Nicolas J.
    Reese, Timothy G.
    Ebrahimi, Behzad
    Normandin, Marc D.
    Shoup, Timothy M.
    Alpert, Nathaniel M.
    El Fakhri, Georges
    Ouyang, Jinsong
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 326 - 343