PERFORMANCE OF THE TOPAZ FORWARD CALORIMETER AT THE TRISTAN EXPERIMENT

被引:24
|
作者
HAYASHII, H [1 ]
NOGUCHI, S [1 ]
FUJIWARA, N [1 ]
IIDA, N [1 ]
MURAMATSU, K [1 ]
NAGIRA, T [1 ]
YOAKE, Y [1 ]
NAKAJIMA, M [1 ]
NISHIOKA, H [1 ]
OHKURA, M [1 ]
IKEDA, H [1 ]
TAUCHI, T [1 ]
KAWABATA, S [1 ]
机构
[1] NATL LAB HIGH ENERGY PHYS,TSUKUBA,IBARAKI 305,JAPAN
关键词
D O I
10.1016/0168-9002(92)90902-G
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We constructed a new forward calorimeter which covers a small polar angular region in the TOPAZ detector at the TRISTAN e+e- storage ring of KEK. It comprises large BGO crystals with a silicon photodiode readout system for energy measurements, and silicon strip detectors for position measurements. It has been operating since November 1989. We present detailed design considerations and the performance from test beam measurements and e+e- colliding beam experiments. We also show the results of luminosity measurements and discuss the systematic errors.
引用
收藏
页码:202 / 216
页数:15
相关论文
共 50 条
  • [1] TOPAZ BARREL ELECTROMAGNETIC CALORIMETER AT TRISTAN, KEK
    KAWABATA, S
    SUGAHARA, R
    TAUCHI, T
    UJIIE, N
    WATANABE, Y
    KURODA, S
    SUWADA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (01): : 11 - 20
  • [2] Performance of a forward Hadron calorimeter for the ALICE experiment
    Arnaldi, R.
    Chiavassa, E.
    Cicalo, C.
    Cortese, P.
    De Falco, A.
    Dellacasa, G.
    De Marco, N.
    Gallio, M.
    Macciotta, P.
    Masoni, A.
    Musso, A.
    Oppedisano, C.
    Piccotti, A.
    Puddu, G.
    Scomparin, E.
    et. al.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 1 : 8 - 11
  • [3] Performance of a forward neutron calorimeter for the ALICE experiment.
    Arnaldi, R
    Chiavassa, E
    Cicalò, C
    Cortese, P
    De Falco, A
    Dellacasa, G
    De Marco, N
    Ferretti, A
    Gallio, M
    Macciotta, P
    Masoni, A
    Mereu, P
    Musso, A
    Oppedisano, C
    Piccotti, A
    Puddu, G
    Scalas, E
    Scomparin, E
    Serci, S
    Siddi, E
    Usai, C
    Vercellin, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1503 - 1505
  • [4] Performance of a forward neutron calorimeter for the ALICE experiment.
    Arnaldi, R
    Chiavassa, E
    Cicalò, C
    Cortese, P
    De Falco, A
    Dellacasa, G
    De Marco, N
    Ferretti, A
    Gallio, M
    Macciotta, P
    Masoni, A
    Mereu, P
    Musso, A
    Oppedisano, C
    Piccotti, A
    Puddu, G
    Scalas, E
    Scomparin, E
    Serci, S
    Siddi, E
    Usai, G
    Vercellin, E
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 237 - 239
  • [5] PERFORMANCE-TEST OF THE TOPAZ BARREL CALORIMETER
    KURODA, S
    KAWABATA, S
    SUGAHARA, R
    TAUCHI, T
    UJIIE, N
    WATANABE, Y
    SUWADA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (03): : 460 - 467
  • [6] Performance studies for the prototype III of CASTOR — forward calorimeter at the CMS experiment
    S. Başeǧmez
    D. d’ Enterria
    L. Gouskos
    I. Katkov
    P. Katsas
    L. Khein
    Indian Journal of Physics, 2010, 84 : 1689 - 1693
  • [7] Performance studies of prototype II for the CASTOR forward calorimeter at the CMS experiment
    X. Aslanoglou
    M.N. Bakirci
    S. Cerci
    A. Cyz
    D. d’Enterria
    E. Gladysz-Dziadus
    L. Gouskos
    A. Ivashkin
    C. Kalfas
    P. Katsas
    A. Kuznetsov
    Y. Musienko
    A.D. Panagiotou
    E. Vlasov
    The European Physical Journal C, 2007, 52 : 495 - 506
  • [8] First performance studies of a prototype for the CASTOR forward calorimeter at the CMS experiment
    Aslanoglou, X.
    Cyz, A.
    Davis, N.
    D'Enterria, D.
    Gladysz-Dziadus, E.
    Kalfas, C.
    Musienko, Y.
    Kuznetsov, A.
    Panagiotou, A. D.
    ACTA PHYSICA POLONICA B, 2008, 39 (06): : 1429 - 1453
  • [9] Performance studies of prototype II for the CASTOR forward calorimeter at the CMS experiment
    Aslanoglou, X.
    Bakirci, M. N.
    Cerci, S.
    Cyz, A.
    d'Enterria, D.
    Gladysz-Dziadus, E.
    Gouskos, L.
    Ivashkin, A.
    Kalfas, C.
    Katsas, P.
    Kuznetsov, A.
    Musienko, Y.
    Panagiotou, A. D.
    Vlasov, E.
    EUROPEAN PHYSICAL JOURNAL C, 2007, 52 (02): : 495 - 506
  • [10] Performance studies for the prototype III of CASTOR - forward calorimeter at the CMS experiment
    Basegmez, S.
    d' Enterria, D.
    Gouskos, L.
    Katkov, I.
    Katsas, P.
    Khein, L.
    INDIAN JOURNAL OF PHYSICS, 2010, 84 (12) : 1689 - 1693