COMPARISON OF 3 COMMERCIALLY AVAILABLE ENZYME IMMUNOASSAYS FOR THE SCREENING OF AUTOANTIBODIES TO EXTRACTABLE NUCLEAR ANTIGENS

被引:18
|
作者
JASKOWSKI, TD [1 ]
SCHRODER, C [1 ]
MARTINS, TB [1 ]
MOURITSEN, L [1 ]
HILL, HR [1 ]
机构
[1] UNIV UTAH, MED CTR, DEPT PATHOL, SALT LAKE CITY, UT 84108 USA
关键词
ANTINUCLEAR ANTIBODIES; EXTRACTABLE NUCLEAR ANTIGENS; AUTOANTIBODIES; OUCHTERLONY DOUBLE DIFFUSION; ENZYME IMMUNOASSAY;
D O I
10.1002/jcla.1860090304
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The initial screening test used in the diagnosis of connective tissue diseases is based on the detection of antinuclear antibodies (ANA) by indirect immunofluorescence (IFA). When the ANA screen is positive, it is often useful to determine the specificity of the autoantibody to a series of extractable nuclear antigens (ENA), a procedure that has been classically performed by double immunodiffusion. Testing large numbers of clinical specimens for autoantibodies to ENA by double diffusion techniques can be time-consuming and expensive. ENA screening systems that employ enzyme immunoassay (EIA) technology have recently become commercially available. We compared three EIA ENA assays to classic Ouchterlony double diffusion techniques. Furthermore, the sensitivity of each antigen and methodology (including ANA immunofluorescence using HEp-2 cells) was tested using ENA positive sera possessing single autoantibodies. Two of the three EIAs that detected immunoglobulin G type autoantibodies to Smith (Sm), ribonucleoprotein (RNP), Sjogren's syndrome-associated antigens Ro (SSA) and La (SSB), were provided by INOVA and Sigma Diagnostics. A third EIA, which also included scleroderma-associated antigen 70 (SCL-70/DNA-topoisomerase 1) and histidyl-tRNA synthetase (JO-1) in addition to the four previously stated antigens, was provided by Clark Laboratories. This latter ENA screen detected IgG, IgA, and IgM type autoantibodies. Included in the study were sera covering a wide variety of anti-nuclear and other autoantibodies. Sensitivity was 100% for all EIA ENA screens when compared to Ouchterlony double diffusion and specificity exceeded 95% in each case. Sensitivity studies showed Ouchterlony to be less sensitive than EIA when detecting low levels of autoantibodies to ENA. After the detection of ANA antibody by IFA, EIAs utilizing combined antigens can be used to screen large numbers of clinical specimens for autoantibodies against SSA, SSB, Sm, RNP/SCL-70, and Jo-1 prior to confirmation by Ouchterlony double diffusion. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 50 条
  • [1] A RAPID SCREENING ENZYME LINKED IMMUNOSORBENT-ASSAY FOR AUTOANTIBODIES TO EXTRACTABLE NUCLEAR ANTIGENS
    WARLOW, R
    CARRANO, J
    DAWKINS, R
    DIAGNOSTIC IMMUNOLOGY, 1984, 2 (03): : 154 - 160
  • [2] Evaluation of automated enzyme immunoassays for the detection of antibodies to extractable nuclear antigens
    Bossuyt, X
    Padalko, E
    Willebrords, L
    Godefridis, G
    Marien, G
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (07) : 658 - 659
  • [3] A range of enzyme immunoassays for measuring antibodies to extractable nuclear antigens.
    Budd, R
    Harley, E
    Bradwell, AR
    CLINICAL CHEMISTRY, 2002, 48 (06) : A166 - A166
  • [4] Comparison of Two Commercially Available Fentanyl Screening Immunoassays for Clinical Use
    Budelier, Melissa M.
    Franks, Caroline E.
    Logsdon, Nicole
    Jannetto, Paul J.
    Scott, Mitchell G.
    Roper, Stephen M.
    Farnsworth, Christopher W.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2020, 5 (06): : 1277 - 1286
  • [5] COMPARISON OF 2 COMMERCIALLY AVAILABLE ENZYME IMMUNOASSAYS FOR DETECTION OF CLOSTRIDIUM-DIFFICILE IN STOOL SPECIMENS
    ALTAIE, SS
    MEYER, P
    DRYJA, D
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (01) : 51 - 53
  • [6] COMPARISON OF 5 COMMERCIALLY AVAILABLE ENZYME IMMUNOASSAYS FOR DETECTION OF ANTIBODIES TO CYTOMEGALOVIRUS IN SERA WITH A REFERENCE TEST
    ALBERT, S
    ENZENSBERGER, R
    WEINDEL, M
    KUHNL, P
    DOERR, HW
    ARZTLICHE LABORATORIUM, 1990, 36 (04): : 87 - 95
  • [7] Efficiency of different strategies to detect autoantibodies to extractable nuclear antigens
    Almeida Gonzalez, Delia
    Cabrera de Leon, Antonio
    Rodriguez Perez, Maria del Cristo
    Brito Diaz, Buenaventura
    Gonzalez Hernandez, Ana
    Garcia Garcia, Diego
    Vazquez Moncholi, Carmen
    Aguirre Jaime, Armando
    JOURNAL OF IMMUNOLOGICAL METHODS, 2010, 360 (1-2) : 89 - 95
  • [8] A comparison of ELISA assays as routine diagnostic test for detection of autoantibodies against extractable nuclear antigens
    Van Duijnhoven, HLP
    Van de Warenburg, FJM
    Willems, RJWP
    Ermens, AAM
    CLINICAL BIOCHEMISTRY, 1999, 32 (03) : 179 - 183
  • [9] Comparison of the diagnostic accuracy of three commercially available enzyme immunoassays for anti-p53 antibodies
    Rohayem, J
    Conrad, K
    Zimmermann, T
    Frank, KH
    CLINICAL CHEMISTRY, 1999, 45 (11) : 2014 - 2016
  • [10] Detection of autoantibodies for extractable nuclear antigens by LG Immunoblot kit.
    Chae, J
    Kim, B
    Oh, H
    CLINICAL CHEMISTRY, 2002, 48 (06) : A163 - A163