ACTIVE CURRENT ELECTRODES FOR IN-VIVO ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:20
|
作者
JOSSINET, J
TOURTEL, C
JARRY, R
机构
[1] Inst. Nat. de la Sante et de la Recherche Medicale, Lyon
关键词
D O I
10.1088/0967-3334/15/2A/012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The characterization of tissue by means of electrical impedance tomography requires accurate impedance measurements at relatively high frequencies. The present study describes the design and fabrication of broad-band, active, current electrodes for in vivo measurements. This approach eliminates the lead capacitances of the sourcing electrodes. The value of the resistors used were computed according to a protocol taking into account the constraints of a given application and the values and tolerances of the available components. Additional selection of the components further reduced the variability in circuit performance. The current sources designed according to the method described are usable at frequencies higher than 1 MHz, for differential load impedances up to 2000 OMEGA. The parallel output conductance for each active electrode is 0.85 muS+/-2%. The design method is valid for either adjacent or diametric drive, and can be applied to various applications by modifying the shape of the electrode.
引用
收藏
页码:A83 / A90
页数:8
相关论文
共 50 条
  • [1] USING COMPOUND ELECTRODES IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (01) : 29 - 34
  • [2] ELECTRICAL-IMPEDANCE TOMOGRAPHY - A REVIEW OF CURRENT LITERATURE
    JONGSCHAAP, HCN
    WYTCH, R
    HUTCHISON, JMS
    KULKARNI, V
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 (03) : 165 - 174
  • [3] A CURRENT INJECTING DEVICE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BLAD, B
    LINDSTROM, K
    BERTENSTAM, L
    PERSSON, BRR
    HOLMER, NG
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : A69 - A77
  • [4] ELECTRICAL-IMPEDANCE TOMOGRAPHY
    不详
    SEMAINE DES HOPITAUX, 1993, 69 (28): : 855 - 855
  • [5] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 3 - 4
  • [6] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 : U3 - U3
  • [7] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : UA1 - UA1
  • [8] MULTIFREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RECORD, PM
    GADD, R
    VINTHER, F
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 67 - 72
  • [9] A RECONSTRUCTION ALGORITHM OF ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH OPTIMAL CONFIGURATION OF THE DRIVEN ELECTRODES
    KYRIACOU, GA
    KOUKOURLIS, CS
    SAHALOS, JN
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) : 430 - 438
  • [10] DETERMINATION OF OPTIMUM INJECTED CURRENT PATTERNS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KOKSAL, A
    EYUBOGLU, BM
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 : A99 - A109