EVALUATION OF NEW RAPID OFFICE TEST FOR MICROALBUMINURIA AND ITS COMPARISON TO FULLY QUANTITATIVE RADIOIMMUNOASSAY

被引:6
|
作者
NEUMAN, RG
BONOMINI, LV
BRAUNSTEIN, SN
机构
[1] UNIV PENN,DEPT MED,PHILADELPHIA,PA 19104
[2] UNIV PARMA,DEPT ENDOCRINOL,I-43100 PARMA,ITALY
关键词
D O I
10.2337/diacare.13.10.1069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A novel enzyme-linked immunosorbent assay (ELISA [Dialbumin]) for rapid office measurement of microalbuminuria was evaluated and its performance compared with that of a commercially available radioimmunoassay (double-antibody albumin). Urine samples containing between 0.75 and 1800 μg/ml of albumin were obtained from 31 diabetic patients and assayed by both methods. A comparison of the paired values obtained from the two methods gave a correlation coefficient of >0.99. The Dialbumin assay, which used detachable eight-well strips (1 strip/sample), 10-min incubation, tap water wash, and a 2-min color development step, was read on both an ELISA reader and a hand-held analytical device (Acc-U-Dial) designed specifically for this test. The findings of this study indicate that the Dialbumin assay, used in conjunction with the Acc-U-Dial device, affords a rapid, convenient, and sensitive method for quantitative determination of a broad range (0.3-1280 μg/ml) of urinary albumin levels in the office setting.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [1] RAPID DETECTION OF MICROALBUMINURIA IN DIABETIC-PATIENTS BY AN AGGLUTINATION INHIBITION TEST - COMPARISON WITH RADIOIMMUNOASSAY
    GIAMPIETRO, O
    MICCOLI, R
    CLERICO, A
    DIPALMA, L
    BERTOLOTTO, A
    ANICHINI, R
    NAVALESI, R
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1986, 30 (04): : 215 - 219
  • [2] Rapid screening test evaluation for microalbuminuria in diabetes mellitus
    I. Fernández Fernández
    J. M. Páez Pinto
    T. Hermosín Bono
    P. Vázquez Garijo
    M. A. Ortiz Camuñez
    M. A. Tarilonte Delgado
    Acta Diabetologica, 1998, 35 : 199 - 202
  • [3] Rapid screening test evaluation for microalbuminuria in diabetes mellitus
    Fernández, IF
    Pinto, JMP
    Bono, TH
    Garijo, PV
    Camuñez, MAO
    Delgado, MAT
    ACTA DIABETOLOGICA, 1998, 35 (04) : 199 - 202
  • [4] A NEW RADIOIMMUNOASSAY FOR THE DETECTION OF MICROALBUMINURIA, WITH A COMPARISON TO OTHER URINARY PROTEIN DETERMINATIONS
    ELSHAMI, AS
    DURHAM, AP
    CLINICAL CHEMISTRY, 1986, 32 (06) : 1142 - 1142
  • [5] MICRAL-TEST - A NEW SEMIQUANTITATIVE RAPID TEST FOR DETECTION OF MICROALBUMINURIA
    MANEGOLD, C
    HASSLACHER, C
    WAHL, P
    KIDNEY INTERNATIONAL, 1991, 39 (06) : 1309 - 1309
  • [6] Evaluation of a semi-quantitative test strip for the screening of microalbuminuria.
    Aaberg, DA
    CLINICAL CHEMISTRY, 1999, 45 (06) : A79 - A79
  • [7] Multicenter evaluation of the Micral-Test II test strip, an immunologic rapid test for the detection of microalbuminuria
    Mogensen, CE
    Viberti, GC
    Peheim, E
    Kutter, D
    Hasslacher, C
    Hofmann, W
    Renner, R
    Bojestig, M
    Poulsen, PL
    Scott, G
    Thoma, J
    Kuefer, J
    Nilsson, B
    Gambke, B
    Mueller, P
    Steinbiss, J
    Willamowski, KD
    DIABETES CARE, 1997, 20 (11) : 1642 - 1646
  • [8] EVALUATION OF A RAPID IN OFFICE SERUM TEST FOR HELICOBACTER-PYLORI
    YOUNG, EL
    CUTLER, AF
    GASTROENTEROLOGY, 1995, 108 (04) : A264 - A264
  • [9] THE RAPID HYPEREMIA PREGNANCY TEST IN EQUIDS - ITS QUANTITATIVE EVALUATION AT DIFFERENT TIME INTERVALS
    ZONDEK, B
    SULMAN, F
    ENDOCRINOLOGY, 1947, 40 (05) : 322 - 326
  • [10] RAPID DETECTION OF ROTAVIRUS IN STOOL BY LATEX AGGLUTINATION - COMPARISON WITH RADIOIMMUNOASSAY AND ELECTRON-MICROSCOPY AND CLINICAL-EVALUATION OF THE TEST
    HAIKALA, OJ
    KOKKONEN, JO
    LEINONEN, MK
    NURMI, T
    MANTYJARVI, R
    SARKKINEN, HK
    JOURNAL OF MEDICAL VIROLOGY, 1983, 11 (02) : 91 - 97