COMPARISON OF THE ABBOTT CELL DYN-300-SL AND THE COULTER STKS AUTOMATED LEUKOCYTE DIFFERENTIAL

被引:0
|
作者
STROOP, DM [1 ]
MILLERCANFIELD, P [1 ]
TRIPLETT, RC [1 ]
ROBERTS, LP [1 ]
SCHRAMM, RC [1 ]
PERROTTA, G [1 ]
COMER, K [1 ]
SCHUMACHER, HR [1 ]
机构
[1] UNIV CINCINNATI,MED CTR,DEPT PATHOL & LAB MED,CINCINNATI,OH 45267
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:A513 / A513
页数:1
相关论文
共 50 条
  • [1] COMPARISON OF THE ABBOTT CELL DYN-3000-SL AND THE COULTER STKS FOR NONDIFFERENTIAL PARAMETERS
    STROOP, DM
    MILLERCANFIELD, P
    TRIPLETT, RC
    ROBERTS, LP
    SCHRAMM, RC
    PERROTTA, G
    COMER, K
    SCHUMACHER, HR
    BLOOD, 1993, 82 (10) : A514 - A514
  • [2] COMPARISON OF THE ABBOTT CELL-DYN-3000-SL AND THE COULTER-STKS HEMATOLOGY ANALYZERS
    STROOP, DM
    TRIPLETT, RC
    PERROTTA, G
    ROBERTS, LP
    SCHRAMM, RC
    COMER, K
    MILLERCANFIELD, P
    SCHUMACHER, HR
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1994, 24 (03): : 250 - 258
  • [3] CELL DYN 3000 AND COULTER STKS AUTOMATED DIFFERENTIAL COUNTERS
    MILLERCANFIELD, P
    TRIPLETTE, R
    PERROTTA, G
    STROOP, D
    SCHUMACHER, H
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (04) : 463 - 464
  • [4] CELL DYN-3000 AND COULTER STKS AUTOMATED DIFFERENTIAL COUNTERS - REPLY
    CORNBLEET, PJ
    MYRICK, D
    LEVY, R
    JUDKINS, S
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (04) : 464 - 465
  • [5] DETERMINATION OF A NARROW AGE REFERENCE RANGE USING ABBOTT CELL DYN 3000-SL AND COULTER STKS
    STROOP, DM
    PESCE, AJ
    COPELAND, BE
    PERROTTA, G
    SCHUMACHER, HR
    BLOOD, 1994, 84 (10) : A592 - A592
  • [6] COMPARISON OF THE ABBOTT CELL-DYN-3500 AND THE COULTER STKS IN DETERMINATION OF AMNIOTIC-FLUID LAMELLAR BODY NUMBER DENSITY
    FAYNOR, SM
    BROOKS, KP
    RILEY, RS
    CLINICAL CHEMISTRY, 1995, 41 (06) : S164 - S164
  • [7] Coulter STKS vs Abbott cell-dyn 3500 for counting lamellar bodies in amniotic fluid
    Lafler, D
    Mendoza, A
    Poeltler, D
    Wight, N
    LABORATORY MEDICINE, 1998, 29 (05) : 298 - 301
  • [8] AUTOMATED SPUTUM CELL COUNTS - COULTER STKS
    POPOV, T
    GOTTSCHALK, R
    DOLOVICH, J
    KOLENDOWICZ, R
    EFTHIMIADIS, A
    POWERS, P
    HARGREAVE, FE
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1993, 91 (01) : 375 - 375
  • [9] WBC differentials, flagging performance and reticulocyte quantification on the Abbott Cell-DYN 4000 in comparison to the Coulter STKS and the reticulocyte analyzer sysmex R-1000.
    Luthe, H
    Binder, L
    Martetschläger, I
    Oellerich, M
    CLINICAL CHEMISTRY, 1999, 45 (06) : A62 - A62
  • [10] Evaluation of the ABX Cobas Vega automated hematology analyzer and comparison with the Coulter STKS
    FerreroVacher, C
    Sudaka, I
    Jambou, D
    Vanhaeke, D
    Fischer, F
    Bayle, J
    HEMATOLOGY AND CELL THERAPY, 1997, 39 (03): : 149 - 158