EARLY AND LATE CHANGES IN LEFT-VENTRICULAR SYSTOLIC PERFORMANCE AFTER PERCUTANEOUS AORTIC BALLOON VALVULOPLASTY

被引:6
|
作者
HARPOLE, DH
DAVIDSON, CJ
SKELTON, TN
KISSLO, KB
JONES, RH
BASHORE, TM
机构
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1990年 / 66卷 / 03期
关键词
D O I
10.1016/0002-9149(90)90844-Q
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate early and late hemodynamics after aortic valvuloplasty, 17 patients underwent first-pass radionuclide angiocardiography with simultaneous high-fidelity micromanonteter pressure before, 10 minutes after and 6 months after aortic valvuloplasty. Pressure-volume and stress data were assessed. Immediately after the procedure, no significant change was observed in heart rate, systemic blood pressure, cardiac output or aortic insufficiency (as measured by visual or quantitative aortography). The mean and peak transvalvular gradient decreased from 64 to 36 mm Hg (p < 0.001) and 76 to 38 mm Hg (p < 0.001), respectively. The mean aortic valve area increased from 0.5 to 0.8 cm2 (p < 0.001). Using echocardiography, meridional end-systolic wall stress decreased from 81 to 63 · 103 dynes/cm2 (p < 0.001). Left ventricular ejection fraction increased from 0.48 to 0.54 (p < 0.01), end-diastolic volume decreased from 161 to 143 ml (p < 0.001) and end-diastolic pressure decreased from 18 to 13 mm Hg (p < 0.01). Left ventricular stroke work (the area of the pressure-volume loop) also decreased from 17.5 to 14.7 · 106 ergs (p < 0.001). The loop shifted to the left and downward. At the 6-month study, the mean and peak aortic valve gradient increased from 36 to 56 mm Hg (p < 0.001) and 38 to 61 mm Hg (p < 0.001), respectively. The aortic valve area worsened (0.8 to 0.5 cm2, p < 0.001), end-systolic wall stress increased (63 to 84 · 103 dynes/cm2, p < 0.001) and the left ventricular ejection fraction decreased (0.54 to 0.49, p < 0.02). The end-diastolic volume increased (143 to 159 ml) along with the end-diastolic pressure (13 to 21 mm Hg, p < 0.01). Left ventricular stroke work (14.7 to 16.3 · 106 ergs) was not different from baseline. The loop returned toward baseline. The changes seen in ejection fraction, however, were primarily related to changes in loading conditions. At 6 months, restenosis occurred in most patients, but was not always accompanied by a worsening of clinical status. The pressure-volume loop shifted back toward baseline and the ejection fraction decreased as end-systolic stress increased. There were little data to support an intrinsic change in myocardial contractile performance at any postprocedural interval after aortic valvuloplasty. Rather, the changes in ejection dynamics appeared primarily to be a function of altered loading conditions. © 1990.
引用
收藏
页码:327 / 332
页数:6
相关论文
共 50 条
  • [1] CHANGES IN LEFT-VENTRICULAR SYSTOLIC PERFORMANCE IMMEDIATELY AFTER PERCUTANEOUS AORTIC BALLOON VALVULOPLASTY
    HARPOLE, DH
    DAVIDSON, CJ
    SKELTON, TN
    KISSLO, KB
    JONES, RH
    BASHORE, TM
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (18): : 1213 - 1218
  • [2] CHANGES IN LEFT-VENTRICULAR DIASTOLIC PERFORMANCE AFTER AORTIC BALLOON VALVULOPLASTY - ACUTE AND LATE EFFECTS
    SHEIKH, KH
    DAVIDSON, CJ
    HONAN, MB
    SKELTON, TN
    KISSLO, KB
    BASHORE, TM
    BURGESS, R
    SPERO, L
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) : 795 - 803
  • [3] LEFT-VENTRICULAR PERFORMANCE AND CLINICAL OUTCOME AFTER REPEAT BALLOON AORTIC VALVULOPLASTY
    DAVIDSON, CJ
    HARRISON, JK
    LEITHE, ME
    KISSLO, KB
    BASHORE, TM
    ANNALS OF INTERNAL MEDICINE, 1990, 113 (03) : 250 - 252
  • [4] ACUTE CHANGES IN LEFT-VENTRICULAR FUNCTION AFTER PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY (PBMV)
    RAZZOLINI, R
    RAMONDO, A
    ISABELLA, G
    CARDAIOLI, P
    MARCHIORI, MC
    CAMPISI, F
    CHIOIN, R
    CIRCULATION, 1992, 86 (04) : 595 - 595
  • [5] LEFT-VENTRICULAR DISTENSIBILITY ACUTELY INCREASES AFTER BALLOON AORTIC VALVULOPLASTY
    MELIONES, JN
    BEEKMAN, RH
    ROCCHINI, AP
    SNIDER, AR
    ROSENTHAL, A
    PEDIATRIC RESEARCH, 1989, 25 (04) : A28 - A28
  • [6] DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF THE EFFECT OF BALLOON AORTIC VALVULOPLASTY ON LEFT-VENTRICULAR SYSTOLIC FUNCTION
    FERGUSON, JJ
    BUSH, HS
    RIULI, EP
    AMERICAN HEART JOURNAL, 1989, 117 (01) : 18 - 24
  • [7] IMPROVEMENT IN SYMPTOMS AND LEFT-VENTRICULAR PERFORMANCE AFTER BALLOON AORTIC VALVULOPLASTY IN PATIENTS WITH AORTIC-STENOSIS AND DEPRESSED LEFT-VENTRICULAR EJECTION FRACTION
    SAFIAN, RD
    WARREN, SE
    BERMAN, AD
    DIVER, DJ
    MCKAY, LL
    COME, PC
    GROSSMAN, W
    MCKAY, RG
    CIRCULATION, 1988, 78 (05) : 1181 - 1191
  • [8] Changes of left ventricular function after percutaneous balloon mitral valvuloplasty in mitral stenosis with impaired left ventricular performance
    Lee, TM
    Su, SF
    Chen, MF
    Liau, CS
    Lee, YT
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 56 (03) : 211 - 215
  • [9] LEFT-VENTRICULAR PERFORATION DURING PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY
    MANGA, P
    SINGH, S
    BRANDIS, S
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (04): : 317 - 319
  • [10] EFFECT OF BALLOON AORTIC VALVULOPLASTY ON THE DYNAMICS OF LEFT-VENTRICULAR EJECTION
    FERGUSON, JJ
    BUSH, HS
    RIULI, EP
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 18 (02): : 73 - 78