MICROSTRUCTURAL INVESTIGATION OF BONE-CEMENT INTERFACE

被引:20
|
作者
SAVARINO, L
STEA, S
CIAPETTI, G
PAGANETTO, G
DONATI, ME
ALVERGNA, P
PIZZOFERRATO, A
机构
[1] Laboratory for Biocompatibility Research on Implant Materials, Istituti Ortopedici Rizzoli, Bologna
来源
关键词
D O I
10.1002/jbm.820290605
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We evaluated the microstructural characteristics of newly formed bone tissue at the interface with cement. The bone-cement interfaces of the femoral components of nine hip prostheses retrieved after loosening were investigated by means of X-ray diffraction on microareas and microhardness. The bone far from the interface bf two stable prostheses was used as a control. The newly formed bone adjacent to cement in the loosened prostheses showed a maturity degree lower than that of bone adjacent to cement in stable prostheses. The lattice parameters of bone apatite did not show significant variations as compared to the reference values. Bone trabeculae at the interface with loosened prostheses often showed an osteoid lining characterized by a strongly demineralized lamellar and haversian structure. Radioopaque cement particles are sometimes found in the trabecular bone tissue around the prosthesis. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:701 / 705
页数:5
相关论文
共 50 条
  • [1] THE EFFECT OF POLYMETHYLMETHACRYLATE BONE-CEMENT VIBRATION ON THE BONE-CEMENT INTERFACE
    THOMAS, AMC
    MCMINN, DJW
    HADDAWAY, M
    MCCALL, IW
    [J]. CELLS AND MATERIALS, 1992, 2 (02): : 163 - 168
  • [2] The eburnated bone-cement interface
    Kamat, Yogeesh D.
    Crocombe, Andrew
    Bradley, William Neil
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2014, 25 (05): : 484 - 487
  • [3] Stress shielding in bone of a bone-cement interface
    Zhang, Qing-Hang
    Cossey, Andrew
    Tong, Jie
    [J]. MEDICAL ENGINEERING & PHYSICS, 2016, 38 (04) : 423 - 426
  • [4] A CRACK MODEL OF A BONE-CEMENT INTERFACE
    CLECH, JP
    KEER, LM
    LEWIS, JL
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03): : 235 - 243
  • [5] WEIGHT BEARING AND THE BONE-CEMENT INTERFACE
    ANDERSSON, GBJ
    GITELIS, S
    GALANTE, JO
    ROSTOKER, W
    ANDREACCHI, TP
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (04): : 465 - 465
  • [7] Effect of cement modulus on the shear properties of the bone-cement interface
    Funk, MJ
    Litsky, AS
    [J]. BIOMATERIALS, 1998, 19 (17) : 1561 - 1567
  • [8] The effect of different cement insertion techniques on the bone-cement interface
    Horne, JG
    Bruce, W
    Devane, PA
    Teoh, HH
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (05): : 579 - 583
  • [9] STRESS TRANSFER AT THE FEMORAL BONE BONE-CEMENT INTERFACE AS A FUNCTION OF THE CEMENT THICKNESS
    JANSSON, V
    HEIMKES, B
    ZIMMER, M
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1993, 112 (02) : 65 - 68
  • [10] Effect of bone porosity on the mechanical integrity of the bone-cement interface
    Graham, J
    Ries, M
    Pruitt, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (10): : 1901 - 1908