DISTRIBUTION OF STEADY-STATE CATHODIC CURRENTS UNDERNEATH A DISBONDED COATING

被引:43
|
作者
BROUSSEAU, R
QIAN, S
机构
关键词
CATHODIC PROTECTION; COATINGS; DISBONDMENT; HYDROGEN GAS; PIPELINE CORROSION; POTENTIAL;
D O I
10.5006/1.3293481
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pipeline corrosion frequently persists underneath disbonded coatings on pipelines that appear to be well protected cathodically. Application of higher cathodic potentials for improved protection may produce hydrogen gas (H-2) bubbles that block current flow underneath a disbonded coating. A project was undertaken to determine whether an increase in applied potential results in higher polarization levels on the crevice steel underneath a disbonded coating. With a higher applied potential, pH levels in a crevice should increase. Steady-state cathodic protection experiments were performed at three applied potentials in an electrochemical cell simulating the crevice steel under a disbonded coating. The recorded profiles showed that higher levels of protection underneath a disbonded coating could be achieved by applying higher cathodic potentials. Penetration of the cathodic currents underneath a disbonded coating also was more difficult in higher resistivity solutions.
引用
收藏
页码:907 / 911
页数:5
相关论文
共 50 条
  • [1] INVESTIGATING THE EFFECT OF PULSE CATHODIC PROTECTION UNDERNEATH A DISBONDED COATING
    BROUSSEAU, R
    QIAN, S
    GUMMOW, B
    [J]. MATERIALS PERFORMANCE, 1993, 32 (06) : 21 - 26
  • [2] Modeling pipeline crevice corrosion under a disbonded coating with or without cathodic protection under transient and steady state conditions
    Song, F. M.
    Sridhar, N.
    [J]. CORROSION SCIENCE, 2008, 50 (01) : 70 - 83
  • [3] STEADY-STATE SPIN DENSITIES AND CURRENTS
    Culcer, Dimitrie
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2008, 22 (27): : 4765 - 4791
  • [4] THE STEADY-STATE VOLUME OF DISTRIBUTION
    BOCCHIALINI, BM
    [J]. PHARMACOLOGICAL RESEARCH, 1992, 25 : 186 - 187
  • [5] Transient and steady-state currents in epoxy resin
    Guillermin, C
    Rain, P
    Rowe, SW
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (03) : 515 - 524
  • [6] Steady-state currents in sharp stochastic ratchets
    Klosek, MM
    Cox, RW
    [J]. PHYSICAL REVIEW E, 1999, 60 (04): : 3727 - 3735
  • [7] Bounds on skewness and kurtosis of steady-state currents
    Ptaszynski, Krzysztof
    [J]. PHYSICAL REVIEW E, 2022, 106 (02)
  • [8] Amperometric biosensors with a laminated distribution of enzymes in their coating. Steady-state kinetics
    Sorochinskii, VV
    Kurganov, BI
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2): : 45 - 51
  • [9] CATHODIC PROTECTION POTENTIAL PENETRATION UNDER DISBONDED PIPELINE COATING
    JACK, TR
    VANBOVEN, G
    WILMOTT, M
    SUTHERBY, RL
    WORTHINGHAM, RG
    [J]. MATERIALS PERFORMANCE, 1994, 33 (08) : 17 - 21
  • [10] Modeling pipeline corrosion under a disbonded coating under the influence of underneath flow
    Song, F. M.
    Sridhar, N.
    [J]. CORROSION, 2008, 64 (01) : 40 - 50