MASS-TRANSFER FROM A DROP .1. EXPERIMENTAL-STUDY AND COMPARISON WITH EXISTING CORRELATIONS

被引:18
|
作者
SCHWARZ, J
SMOLIK, J
机构
[1] Institute of Chemical Process Fundamentals, Academy of Sciences of the Czech Republic, 165 02 Prague 6
关键词
D O I
10.1016/0017-9310(94)90315-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study was conducted to measure the rates of mass transfer from a water drop, suspended from a quartz capillary in a stream of a hot air flowing upward in a vertical wind tunnel. Measurements were made for bulk temperature T(infinity) = 314-449 K, drop temperature T0 = 287-315 K, free stream velocity U(infinity) = 0.5-1.7 m s-1, drop diameter d = 0.7-2.3 mm, dimensionless driving force B = 0.007-0.068, Re = 30-180 and Sc = 0.62. The data were compared with results of previous works. It was found that existing correlations proposed for higher mass transfer conditions do not improve experimental data interpretation
引用
收藏
页码:2139 / 2143
页数:5