DETERMINATION OF SOLUTION IONS BY ELECTROSPRAY MASS-SPECTROMETRY

被引:55
|
作者
AGNES, GR [1 ]
HORLICK, G [1 ]
机构
[1] UNIV ALBERTA, DEPT CHEM, EDMONTON T6G 2G2, ALBERTA, CANADA
关键词
MASS SPECTROMETRY; ELECTROSPRAY; ELEMENTAL ANALYSIS;
D O I
10.1366/000370294774368965
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Spectral results are presented illustrating the capability of electrospray mass spectrometry (ES-MS) for the determination of the composition of solution samples. The solution components that can be determined include the elemental and molecular forms of anions and cations. Three modes of positive-ion ES-MS are described: the ion cluster mode, the metal-ion mode, and an intermediate mode. The modes are established by operating the electrospray source at specific voltages and curtain gas flow rate values, and each mode provides a unique mass spectral picture of the solution components with primary focus on cationic species (i.e., metal ions). Results are also presented for operation of the electrospray source in negative-ion mode. In this mode both elemental anions (i.e., halides) and molecular anions (i.e., oxo-anions) can be determined.
引用
收藏
页码:655 / 661
页数:7
相关论文
共 50 条
  • [1] FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY
    KEBARLE, P
    TANG, L
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (22) : A972 - A986
  • [2] MECHANISM OF PRODUCTION OF IONS IN ELECTROSPRAY MASS-SPECTROMETRY
    ASHTON, DS
    BEDDELL, CR
    COOPER, DJ
    GREEN, BN
    OLIVER, RWA
    [J]. ORGANIC MASS SPECTROMETRY, 1993, 28 (06): : 721 - 728
  • [3] THERMALLY INDUCED DISSOCIATION OF IONS FROM ELECTROSPRAY MASS-SPECTROMETRY
    ROCKWOOD, AL
    BUSMAN, M
    UDSETH, HR
    SMITH, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (12) : 582 - 585
  • [4] ELECTROSPRAY MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY OF SYNTHETIC MULTICOMPONENT PEPTIDE MIXTURES - DETERMINATION OF COMPOSITION AND PURITY
    METZGER, JW
    KEMPTER, C
    WIESMULLER, KH
    JUNG, G
    [J]. ANALYTICAL BIOCHEMISTRY, 1994, 219 (02) : 261 - 277
  • [5] ADVANCES IN ELECTROSPRAY MASS-SPECTROMETRY
    WHITEHOUSE, CM
    SHEN, S
    BANKS, FJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 75 - ANYL
  • [6] DEPENDENCE OF ION INTENSITY IN ELECTROSPRAY MASS-SPECTROMETRY ON CONCENTRATION IN THE SOLUTION
    KEBARLE, P
    TANG, L
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 93 - ANYL
  • [7] DROPLET ELECTROSPRAY MASS-SPECTROMETRY
    HAGER, DB
    DOVICHI, NJ
    KLASSEN, J
    KEBARLE, P
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : 3944 - 3949
  • [8] PREFORMING IONS IN SOLUTION VIA CHARGE-TRANSFER COMPLEXATION FOR ANALYSIS BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY
    VANBERKEL, GJ
    MCLUCKEY, SA
    GLISH, GL
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (18) : 2064 - 2068
  • [9] HYBRID TANDEM MASS-SPECTROMETRY OF ELECTROSPRAY-PRODUCED PEPTIDE IONS
    TOMER, KB
    MCGOWN, SR
    DETERDING, LJ
    [J]. ORGANIC MASS SPECTROMETRY, 1993, 28 (05): : 534 - 541
  • [10] DETERMINATION OF DEUTERIUM IN WATER BY MASS-SPECTROMETRY WITH METASTABLE IONS
    SCHMIT, JP
    BOULAY, G
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (14) : 2359 - 2361