FUZZY CONTROL CONCEPT FOR A TOTAL ARTIFICIAL-HEART

被引:12
|
作者
KAUFMANN, R
BECKER, K
NIX, C
REUL, H
RAU, G
机构
[1] Helmholtz-Institute for Biomedical Engineering, RWTH, Aachen
关键词
TAH CONTROL; FUZZY CONTROL; CONTROL SENSORS; IN VITRO TESTING;
D O I
10.1111/j.1525-1594.1995.tb02340.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of an electromechanically driven total artificial heart (Helmholtz-TAH) was initiated in 1990. Anatomical fitting, biocompatibility, and automatic physiologic adaptation of pump output are the basic requirements that characterize the overall TAH concept. For evaluation of these features, a TAH labtype was developed. It provides most features of the conceptual artificial heart and supports in vitro testing of energy conversion, pump behavior, structural parts, sensors, and control concepts. A fuzzy controller has been implemented for adaptation of the pump rate to body perfusion demand by left pump chamber filling detection. This controller will be an important element of a future extensive TAH control system. The implementation is supported by a professional fuzzy control development tool that allows on-line and real time optimization of control strategies for dynamic processes. The first experiments proved the feasibility and the advantages of this fuzzy control concept. The first in vitro test results are presented.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [2] OPTIMUM CONTROL MODE FOR A TOTAL ARTIFICIAL-HEART
    TAKATANI, S
    HARASAKI, H
    KOIKE, S
    YADA, I
    YOZU, R
    FUJIMOTO, L
    MURABAYASHI, S
    JACOBS, G
    KIRALY, R
    NOSE, Y
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 148 - 153
  • [3] THE TOTAL ARTIFICIAL-HEART
    JARVIK, RK
    [J]. SCIENTIFIC AMERICAN, 1981, 244 (01) : 74 - &
  • [4] THE TOTAL ARTIFICIAL-HEART
    BAGBY, MM
    BINGGELI, B
    CURRENT, C
    DELOACH, C
    NICHOLSON, C
    PURVIANCE, K
    ROTH, G
    WEBER, J
    WEST, N
    WOOD, L
    [J]. AMERICAN JOURNAL OF NURSING, 1987, 87 (08) : 1050 - 1058
  • [5] DEVELOPMENT OF TOTAL ARTIFICIAL-HEART
    FUKUMASU, H
    [J]. ARCHIV FUR JAPANISCHE CHIRURGIE, 1980, 49 (03): : 225 - 268
  • [6] TOTAL ARTIFICIAL-HEART IMPLANTATION
    BERENSON, CK
    GROSSER, BI
    [J]. ARCHIVES OF GENERAL PSYCHIATRY, 1984, 41 (09) : 910 - 916
  • [7] STUDY ON THE TOTAL ARTIFICIAL-HEART
    HASEGAWA, T
    FUKUNAGA, S
    MATSUMURA, M
    TAGAMI, S
    SUEDA, T
    HAMANAKA, Y
    MURASHITA, J
    TAGUCHI, K
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 871 - 871
  • [8] THE USE OF AN ARTIFICIAL PERICARDIUM WITH A TOTAL ARTIFICIAL-HEART
    DEPAULIS, R
    RIEBMAN, JB
    DELEUZE, P
    MOHAMMAD, FS
    BURNS, GL
    MOREA, M
    OLSEN, DB
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1990, 31 (02): : 202 - 208
  • [9] THE USE OF AN ARTIFICIAL PERICARDIUM WITH A TOTAL ARTIFICIAL-HEART
    DEPAULIS, R
    RIEBMAN, JR
    DELEUZE, P
    BURNS, GL
    OLSEN, DB
    [J]. ARTIFICIAL ORGANS, 1987, 11 (04) : 295 - 295
  • [10] DEVELOPMENT OF THE PHYSIOLOGICAL CONTROL SCHEME FOR AN ELECTROHYDRAULIC TOTAL ARTIFICIAL-HEART
    KHANWILKAR, PS
    CRUMP, KR
    BEARNSON, GB
    SMITH, JK
    OLSEN, DB
    [J]. IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 149 - 150