摘要
Using an input grating coupler instrument and monomode optical waveguides, we studied the adsorption of various proteins (e.g. human immunoglobulins G and A (h-IgG and h-IgA), and avidin) on the waveguide surface. In model experiments for immunoassays, we also monitored as a function of time the formation of the immuno-complex Ag-Ab between antigen (Ag) molecules adsorbed on the waveguide surface and antibody (Ab) molecules, for example, of adsorbed h-IgG vs anti-h-IgG, anti-goat-IgG (cross-reaction) and anti-h-IgA (negative test). We also studied the affinity reaction between absorbed protein A and h-IgG. From the measured changes in the effective refractive indices N(TE0) and N(TM0) of the TE0 and TM0 modes, we determined the thickness d(F'), the refractive index n(F'), and the surface coverage GAMMA of the adsorbed protein adlayers and of the immuno-complexes.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 50 条
  • [1] INTEGRATED OPTICAL INPUT GRATING COUPLERS AS CHEMOSENSORS AND IMMUNOSENSORS
    NELLEN, PM
    LUKOSZ, W
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 592 - 596
  • [2] INTEGRATED OPTICAL INPUT GRATING COUPLERS AS DIRECT AFFINITY SENSORS
    NELLEN, PM
    LUKOSZ, W
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4): : 129 - 147
  • [3] INTEGRATED OPTICAL INPUT GRATING COUPLERS AS BIOCHEMICAL SENSORS
    NELLEN, PM
    TIEFENTHALER, K
    LUKOSZ, W
    [J]. SENSORS AND ACTUATORS, 1988, 15 (03): : 285 - 295
  • [4] INPUT AND OUTPUT GRATING COUPLERS AS INTEGRATED OPTICAL BIOSENSORS
    LUKOSZ, W
    CLERC, D
    NELLEN, PM
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1991, 25 (1-3) : 181 - 184
  • [5] OUTPUT GRATING COUPLERS ON PLANAR OPTICAL WAVE-GUIDES AS DIRECT IMMUNOSENSORS
    LUKOSZ, W
    CLERC, D
    NELLEN, PM
    STAMM, C
    WEISS, P
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (03): : 227 - 232
  • [6] GRATING AND PRISM INPUT COUPLERS AS BISTABLE INTEGRATED OPTICAL-ELEMENTS
    LUKOSZ, W
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (12): : 1271 - 1271
  • [7] Planar immunosensors with the application of grating couplers - analysis and design
    Karasinski, Pawel
    [J]. OPTOELECTRONIC AND ELECTRONIC SENSORS VI, 2006, 6348
  • [8] GRATING COUPLERS AS INTEGRATED OPTICAL HUMIDITY AND GAS SENSORS
    TIEFENTHALER, K
    LUKOSZ, W
    [J]. THIN SOLID FILMS, 1985, 126 (3-4) : 205 - 211
  • [9] Direct and Competitive Optical Grating Immunosensors for Determination of Fusarium Mycotoxin Zearalenone
    Szekacs, Inna
    Adanyi, Nora
    Szendro, Istvan
    Szekacs, Andras
    [J]. TOXINS, 2021, 13 (01)
  • [10] SENSITIVITY OF GRATING COUPLERS AS INTEGRATED-OPTICAL CHEMICAL SENSORS
    TIEFENTHALER, K
    LUKOSZ, W
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1989, 6 (02) : 209 - 220