Impact Analysis of Window-Wall Ratio on Heating and Cooling Energy Consumption of Residential Buildings in Hot Summer and Cold Winter Zone in China

被引:34
|
作者
Yang, Qiaoxia [1 ,2 ]
Liu, Meng [1 ,2 ,3 ]
Shu, Chang [4 ]
Mmereki, Daniel [1 ]
Hossain, Md. Uzzal [5 ]
Zhan, Xiang [6 ]
机构
[1] Chongqing Univ, Fac Urban Construct & Environm Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Minist Educ, Chongqing 400045, Peoples R China
[3] Chongqing Univ, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[4] Tongji Univ, Inst Refrigerat & Thermal Engn, Sch Mech Engn, Shanghai 200092, Peoples R China
[5] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
[6] CMCU Engn Co Ltd, Chongqing 400039, Peoples R China
来源
JOURNAL OF ENGINEERING | 2015年 / 2015卷
关键词
D O I
10.1155/2015/538254
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to assess the optimal window-wall ratio and the proper glazing type in different air conditioning system operation modes of residential buildings for each orientation in three typical cities in hot summer and cold winter zone: Chongqing, Shanghai, and Wuhan simulation models were built and analyzed using Designer's Simulation Toolkit (DeST). The study analyzed the variation of annual heating energy demand, annual cooling energy demand, and the annual total energy consumption in different conditions, including different orientations, patterns of utilization of air conditioning system, window-wall ratio, and types of windows. The results show that the total energy consumption increased when the window-wall ratio is also increased. It appears more obvious when the window orientation is east or west. Furthermore, in terms of energy efficiency, low-emissivity (Low-E) glass performs better than hollow glass. From this study, it can be concluded that the influence and sensitivity of window-wall ratio on the total energy consumption are related to the operation mode of air conditioning system, the orientation of outside window, and the glazing types of window. The influence of the factors can be regarded as reference mode for the window-wall ratio when designing residential buildings.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Influence of the window-wall ratio on energy consumption of civil constructions in hot summer and cold winter region
    Chen, Zhen
    He, Jiapeng
    Xu, Qiuyu
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 160 - 167
  • [2] Analysis on urban residential energy consumption of Hot Summer & Cold Winter Zone in China
    Hu, Tianchi
    Yoshino, Hiroshi
    Jiang, Zhongtian
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2013, 6 : 85 - 91
  • [3] Optimization Analysis of the Residential Window-to-Wall Ratio Based on Numerical Calculation of Energy Consumption in the Hot-Summer and Cold-Winter Zone of China
    Liu, Haiqiang
    Zhang, Zhihao
    Ma, Xidong
    Lu, Weite
    Li, Dongze
    Kojima, Shoichi
    [J]. SUSTAINABILITY, 2021, 13 (11)
  • [4] Energy-quota-based integrated solutions for heating and cooling of residential buildings in the Hot Summer and Cold Winter zone in China
    Cao, Xinyun
    Yao, Runming
    Ding, Chao
    Zhou, Nan
    Yu, Wei
    Yao, Jinyang
    Xiong, Jie
    Xu, Qiang
    Pan, Li
    Li, Baizhan
    [J]. ENERGY AND BUILDINGS, 2021, 236
  • [5] Impacts of shading effect from nearby buildings on heating and cooling energy consumption in hot summer and cold winter zone of China
    Ichinose, Toshiaki
    Lei, Lei
    Lin, Ye
    [J]. ENERGY AND BUILDINGS, 2017, 136 : 199 - 210
  • [6] Reducing Energy Consumption and Improving Comfort by Retrofitting Residential Buildings in the Hot Summer and Cold Winter Zone of China
    Tsang, Christopher
    Spentzou, Eftychia
    Lomas, Kevin J.
    He, Miaomiao
    [J]. JOURNAL OF ARCHITECTURAL ENGINEERING, 2022, 28 (04)
  • [7] Environmental performance optimization of window-wall ratio for different window type in hot summer and cold winter zone in China based on life cycle assessment
    Su, Xing
    Zhang, Xu
    [J]. ENERGY AND BUILDINGS, 2010, 42 (02) : 198 - 202
  • [8] The Influence of Window-Wall Ratio on Heating Energy Consumption of Rural House in Severe Cold Regions of China
    Shao, Teng
    Jin, Hong
    Zheng, Wuxing
    Wang, Jin
    [J]. 2020 5TH INTERNATIONAL CONFERENCE ON ADVANCES ON CLEAN ENERGY RESEARCH (ICACER 2020), 2020, 173
  • [9] Energy Efficiency and Sustainability Evaluation of Space and Water Heating in Urban Residential Buildings of the Hot Summer and Cold Winter Zone in China
    Chen, Xiao
    Wen, Yongquan
    Li, Nanyang
    [J]. SUSTAINABILITY, 2016, 8 (10)
  • [10] A Statistical Analysis of Energy Consumption Survey of Public Buildings in a Hot Summer and Cold Winter Coastal Zone of China
    Gong, Xuemei
    Li, Yixuan
    Cai, Junwei
    Ma, Zhenjun
    He, Siyuan
    Pan, Benben
    Lei, Xiaoyu
    [J]. BUILDINGS, 2023, 13 (11)