Preoperative ultrasonographic examination of the radial artery and the cephalic vein and risks of dialysis arterio-venous fistula dysfunction

被引:0
|
作者
Bojakowski, Krzysztof [1 ,2 ]
Gorczyca-Wisniewska, Ewa [3 ]
Szatkowski, Maciej [3 ]
Walecki, Jerzy [3 ]
Andziak, Piotr [1 ,2 ,4 ]
机构
[1] Med Univ Warsaw, Dept Gen Vasc & Oncol Surg, Warsaw, Poland
[2] CSK MSWiA Hosp, Dept Gen & Vasc Surg, Woloska 137 Str, PL-02507 Warsaw, Poland
[3] CMPK Ctr, Dept Radiol & Diagnost Imaging, Warsaw, Poland
[4] Polish Acad Sci, M Mossakowski Inst Clin & Expt Med, Dept Clin Transplantol, Warsaw, Poland
关键词
ultrasonographic examination; risk factor; arterio-venous fistula;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Hemodialysis used as renal replacement therapy requires a well-functioning vascular access. Arterio-venous fistula (AVF) created on the forearm is the best vascular access, but it also reveals numerous complications such as: lack of fistula maturation and hemodynamically significant stenoses. Many risk factors of fistula dysfunction are still not identified. Material/Methods: Radial artery and cephalic vein diameter and patency were ultrasonographically examined before forearm AVF creation. Intima-media complex width, blood flow and peak systolic velocity in distal part of radial artery were measured. Presence of thrombosis and post-inflammatory changes in cephalic vein were also checked. Forearm AVF was created in 66 patients. Fistula US examination was performed 3 and 12 months after operation with measurement of vessel diameter and blood flow. Fistula patency was observed in 24 months after creation. Comparison of pre-and postoperative US examinations between groups with well functioning and thrombosed fistulas was performed. Results: Primary patency of forearm AVF after 12 and 24 months was 65.2% and 53.0%, respectively. Patients with well functioning forearm AVF have significantly bigger cephalic vein diameter and peak systolic velocity in radial artery. We did not observe significant influence of radial artery intima-media complex width and radial artery diameter on AVF function. In postoperative examination, fistula diameter and flow significantly influenced the risk of AVF thrombosis. Conclusions: US examination of radial artery and cephalic vein performed before forearm AVF creation enables identification of patients with greater risk of fistula dysfunction. Cephalic vein diameter and peak systolic velocity are prognostic factors of fistula function. Control postoperative US examination of forearm fistula enables detection of AVF at risk of thrombosis.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [1] SPONTANEOUS ARTERIO-VENOUS FISTULA OF THE VERTEBRAL ARTERY
    GOODDY, W
    SCHECHTER, MM
    BRITISH JOURNAL OF RADIOLOGY, 1960, 33 (395): : 709 - 711
  • [2] Arterio-venous fistula with pseudoaneurysm of renal artery
    Breza, J., Jr.
    Javorka, V., Jr.
    Mizickova, M.
    Goncalves, F. M.
    Breza, J., Sr.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2012, 113 (05): : 289 - 292
  • [3] THE IMPACT OF THE TECHNIQUE OF ARTERIO-VENOUS FISTULA CANNULATION ON THE QUALITY OF DIALYSIS
    Elias, Michelle
    Francois, Helene
    Obada, Erika
    Lorenzo, Hans Kristian
    Charpentier, Bernard
    Durrbach, Antoine
    Beaudreuil, Severine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 212 - 212
  • [4] ARTERIO-VENOUS RENAL FISTULA WITH PSEUDOANEURYSMA OF RENAL ARTERY
    Malek, T.
    Breza, J., Jr.
    Visvaderova, T.
    Slobodnik, L.
    Javorka, V., Jr.
    Breza, J., Sr.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (06) : 661 - 661
  • [5] Effect of preoperative arm warming on arterio-venous fistula outcomes
    Olivier, James
    Harris, Sophie
    Paravastu, Sharath
    Kulkarni, Sachin
    BRITISH JOURNAL OF SURGERY, 2020, 107 : 95 - 95
  • [6] Creation of an Arterio-Venous Fistula Between the Brachial Artery and Basilic Vein with a Saphenous Vein Graft Interposition
    Kara, Hakan
    Uzun, Kemal
    Karaca, Yasar
    Abud, Burcin
    Yilmaz, Hasan
    TURKISH NEPHROLOGY DIALYSIS AND TRANSPLANTATION JOURNAL, 2015, 24 (01): : 113 - 115
  • [7] HYPERTROPHY OF MEDIAN COAT OF ARTERY IN EXPERIMENTAL ARTERIO-VENOUS FISTULA
    SOLBERG, LA
    HARKNESS, RD
    INGEBRIGTSEN, R
    ACTA CHIRURGICA SCANDINAVICA, 1970, 136 (07): : 575 - +
  • [8] Coil embolization of iatrogenic arterio-venous fistula from pulmonary collateral artery to subclavian vein
    Radford, D
    Slaughter, R
    CARDIOLOGY IN THE YOUNG, 2001, 11 (06) : 663 - 665
  • [9] Microsurgery and preemptive haemostasis for distal radio-cephalic arterio-venous fistula in adult
    Pirozzi, Nicola
    Fiaschetti, Pamela
    Giuliani, Luciano
    Coclite, Daniela
    Napoletano, Antonello M.
    Pirozzi, Vincenzo
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 155 - 155
  • [10] Arterio-venous aneurysm: Anastomosis of vein, and suture of artery.
    Godwin, HJ
    BRITISH MEDICAL JOURNAL, 1915, 1915 : 925 - 926