DETECTING LEGIONELLA-PNEUMOPHILA IN WATER-SYSTEMS - A COMPARISON OF VARIOUS DENTAL UNITS

被引:50
|
作者
CHALLACOMBE, SJ [1 ]
FERNANDES, LL [1 ]
机构
[1] UNIV LONDON, UNITED MED & DENT SCH, DEPT ORAL MED & PATHOL, LONDON, ENGLAND
来源
关键词
D O I
10.14219/jada.archive.1995.0239
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The authors sampled 194 dental units over a 44-month period to detect the presence of Legionella pneumophila. They found L. pneumophila, usually in very low numbers, in 25 percent of the units over this time. However, higher counts were collected from 4 percent of the units, primarily from one model. The authors document colony counts collected from nine different models and those collected from air/water syringes vs. high-speed outlets, and they describe the effectiveness of disinfection.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 50 条
  • [1] PREVALENCE OF LEGIONELLA-PNEUMOPHILA IN DENTAL UNIT WATER-SYSTEMS
    CHALLACOMBE, SJ
    FERNANDES, L
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 111 - 111
  • [2] FACTORS PREDISPOSING TO LEGIONELLA-PNEUMOPHILA COLONIZATION IN RESIDENTIAL WATER-SYSTEMS
    LEE, TC
    STOUT, JE
    YU, VL
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1988, 43 (01): : 59 - 62
  • [3] ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM HOSPITAL WATER-SYSTEMS IN VICTORIA
    SWANN, RA
    PEEL, MM
    ROUCH, GJ
    MEDICAL JOURNAL OF AUSTRALIA, 1982, 2 (05) : 226 - 227
  • [4] INFLUENCE OF TEMPERATURE ON THE NUMBER OF LEGIONELLA-PNEUMOPHILA IN HOT WATER-SYSTEMS
    GROOTHUIS, DG
    VEENENDAAL, HR
    DIJKSTRA, HL
    JOURNAL OF APPLIED BACTERIOLOGY, 1985, 59 (06): : 529 - 536
  • [5] LEGIONELLA PNEUMOPHILA AND WATER-SYSTEMS
    GORDON, H
    BRITISH MEDICAL JOURNAL, 1981, 282 (6268): : 988 - 988
  • [6] INFLUENCE OF PLUMBING MATERIALS ON BIOFILM FORMATION AND GROWTH OF LEGIONELLA-PNEUMOPHILA IN POTABLE WATER-SYSTEMS
    ROGERS, J
    DOWSETT, AB
    DENNIS, PJ
    LEE, JV
    KEEVIL, CW
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1994, 60 (06) : 1842 - 1851
  • [7] PREVALENCE AND SIGNIFICANCE OF LEGIONELLA-PNEUMOPHILA CONTAMINATION OF RESIDENTIAL HOT-TAP WATER-SYSTEMS
    ARNOW, PM
    WEIL, D
    PARA, MF
    JOURNAL OF INFECTIOUS DISEASES, 1985, 152 (01): : 145 - 151
  • [8] HOT WATER-SYSTEMS AS SOURCES OF LEGIONELLA-PNEUMOPHILA IN HOSPITAL AND NON-HOSPITAL PLUMBING FIXTURES
    WADOWSKY, RM
    YEE, RB
    MEZMAR, L
    WING, EJ
    DOWLING, JN
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (05) : 1104 - 1110
  • [9] LEGIONELLA PNEUMOPHILA IN DENTAL UNITS
    REINTHALER, F
    MASCHER, F
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1986, 183 (01): : 86 - 88
  • [10] LEGIONELLA-PNEUMOPHILA IN LAKE WATER IN ISRAEL
    BOLDUR, I
    MOR, G
    CAHANA, H
    SOMPOLINSKY, D
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1988, 24 (07): : 381 - 381