HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF DN-2327, A NOVEL NONBENZODIAZEPINE ANXIOLYTIC, AND OR ITS ACTIVE METABOLITE IN HUMAN PLASMA AND URINE

被引:7
|
作者
HUSSEIN, Z
CHU, SY
GRANNEMAN, GR
机构
[1] Drug Metabolism Department, Abbott Laboratories, Abbott Park, IL 60064-3500, D-463, One Abbott Park Road
来源
关键词
D O I
10.1016/0378-4347(93)80202-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and precise high-performance liquid chromatographic procedure has been developed for the determination of a new non-benzodiazepine anxiolytic agent, DN-2327 (I), and its pharmacologically active metabolite, M(II) (II), in human plasma and urine. Extraction of I, II, and the internal standard from plasma and urine samples were achieved using solid-phase extraction. Separation of the analytes was performed on a reversed-phase C18 column. The effluent was monitored with fluorescence detection at excitation and emission maxima of 328 and 367 nm, respectively. The work-up procedure was reproducible and recovered more than 92% of I and II from either plasma or urine. The chromatographic system for plasma and urine extracts allowed complete resolution of I and II from the internal standard with excellent selectivity. For each analyte, the lower detection limits were 0.1 and 1 ng/ml in plasma and urine, respectively. For each analyte, standard curves were linear in the ranges of 0.1-50 and 1-500 ng/ml in plasma and urine, respectively. The method was highly precise, with coefficients of variation for each analyte in quality controls that were generally below 7 and 5% for plasma and urine samples, respectively. The accuracy of the method was good with the deviations between added and calculated concentrations of each analyte being typically within +/- 10% and +/- 5.6% for plasma and urine samples, respectively. The stability of I and II in standard solutions, plasma and urine samples protected from laboratory light was excellent, with no evidence of degradation after 72 h at room temperature, five months at 4-degrees-C, or three months at -20-degrees-C.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 50 条
  • [1] ENANTIOSELECTIVE DETERMINATION OF DN-2327, A NOVEL NONBENZODIAZEPINE ANXIOLYTIC, AND OR ITS ACTIVE METABOLITE IN HUMAN PLASMA AND URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HUSSEIN, Z
    CHU, SY
    GRANNEMAN, GR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 113 - 120
  • [2] DETERMINATION OF LORAJMINE AND ITS METABOLITE AJMALINE IN PLASMA AND URINE BY A NEW HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD
    PADRINI, R
    PIOVAN, D
    GAGLIONE, E
    ZORDAN, R
    FERRARI, M
    THERAPEUTIC DRUG MONITORING, 1992, 14 (05) : 391 - 396
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF DROTAVERINE IN HUMAN PLASMA AND URINE
    BOLAJI, OO
    ONYEJI, CO
    OGUNGBAMILA, FO
    OGUNBONA, FA
    OGUNLANA, EO
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (01): : 93 - 97
  • [4] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF APRINDINE AND ITS ACTIVE DESETHYL METABOLITE IN PLASMA
    KOBARI, T
    NAMEKAWA, H
    ITO, T
    ISHIZAKA, M
    JOURNAL OF CHROMATOGRAPHY, 1983, 278 (01): : 220 - 224
  • [5] SIMPLIFIED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FLOSEQUINAN AND ITS METABOLITE IN PLASMA, SERUM AND URINE
    SLEGOWSKI, MB
    MILLER, C
    PORTER, RS
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (01): : 227 - 232
  • [6] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF AMINEPTINE AND ITS MAIN METABOLITE IN HUMAN-PLASMA
    NICOT, G
    LACHATRE, G
    GONNET, C
    VALETTE, JP
    MERLE, L
    NOUAILLE, Y
    BROMET, N
    JOURNAL OF CHROMATOGRAPHY, 1984, 306 (MAR): : 279 - 290
  • [7] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF DIETHYLAMINE, A METABOLITE OF DISULFIRAM, IN URINE
    NEIDERHISER, DH
    FULLER, RK
    JOURNAL OF CHROMATOGRAPHY, 1982, 229 (02): : 470 - 474
  • [8] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF ADIBENDAN IN PLASMA AND URINE
    REIFF, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 422 : 346 - 352
  • [9] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF DICLOFENAC AND ITS HYDROXY METABOLITES IN HUMAN PLASMA AND URINE
    LANSDORP, D
    JANSSEN, TJ
    GUELEN, PJM
    VREE, TB
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 528 (02): : 487 - 494
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NAVELBINE IN HUMAN PLASMA AND URINE
    NICOT, G
    LACHATRE, G
    MARQUET, P
    BONNAUD, F
    VALLETTE, JP
    ROCCA, JL
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 528 (01): : 258 - 266