ANALYSIS OF SPERM CELL VIABILITY, ACROSOMAL INTEGRITY, AND MITOCHONDRIAL-FUNCTION USING FLOW-CYTOMETRY

被引:261
|
作者
GRAHAM, JK [1 ]
KUNZE, E [1 ]
HAMMERSTEDT, RH [1 ]
机构
[1] PENN STATE UNIV, BIOCHEM PROGRAM, 406 ALTHOUSE LAB, UNIVERSITY PK, PA 16802 USA
关键词
D O I
10.1095/biolreprod43.1.55
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A triple staining procedure was developed to evaluate bull spermatozoa using flow cytometry. Flow cytometric estimates of cell viability, measured by propidium iodide (PI) exclusion, and acrosomal integrity, measured by Pisum sativum agglutinin (PSA) binding acrosomal contents, were equivalent to estimates made by using standard laboratory assays. Mitochondrial function, measured by rhodamine 123 (R123) fluorescence, was depressed by the mitochondrial inhibitors rotenone (64%) or monensin (52%), establishing that mitochondrial damage can be detected. Dilauroylphosphatidylcholine (PC12) or lysophosphatidylcholine (LPC) was used to destabilize sperm membranes. When challenged with 15-30 μM PC12, selective exposure of PSA binding sites occurred without induction of PI uptake or loss of R123 staining. However, PC12 concentrations >60 μM resulted in a loss of R123 fluorescence intensity. In contrast, >1200 μM LPC was required to expose PSA binding sites, which also resulted in PI uptake. By using flow cytometry, these three stains in combination can be used to correlate three different features simultaneously on individual spermatozoa and assay thousands of cells per sample without extensive preparation.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 50 条
  • [1] EVALUATION OF MOUSE SPERM ACROSOMAL STATUS AND VIABILITY BY FLOW-CYTOMETRY
    TAO, J
    CRITSER, ES
    CRITSER, JK
    MOLECULAR REPRODUCTION AND DEVELOPMENT, 1993, 36 (02) : 183 - 194
  • [2] ACROSOMAL INTEGRITY ASSESSED BY FLOW-CYTOMETRY IN MEN WITH VARIABLE SPERM QUALITY
    ENGH, E
    CLAUSEN, OPF
    PURVIS, K
    HUMAN REPRODUCTION, 1991, 6 (08) : 1129 - 1134
  • [3] ASSESSMENT OF THE ACROSOMAL STATUS AND VIABILITY OF HUMAN SPERMATOZOA SIMULTANEOUSLY USING FLOW-CYTOMETRY
    TAO, J
    DU, JY
    CRITSER, ES
    CRITSER, JK
    HUMAN REPRODUCTION, 1993, 8 (11) : 1879 - 1885
  • [4] SIMULTANEOUS MEASUREMENT BY FLOW-CYTOMETRY OF SPERM CELL VIABILITY AND MITOCHONDRIAL-MEMBRANE POTENTIAL RELATED TO CELL MOTILITY
    EVENSON, DP
    DARZYNKIEWICZ, Z
    MELAMED, MR
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1982, 30 (03) : 279 - 280
  • [5] VIABILITY ASSESSMENT OF TURKEY SPERM USING FLUORESCENT STAINING AND FLOW-CYTOMETRY
    DONOGHUE, AM
    GARNER, DL
    DONOGHUE, DJ
    JOHNSON, LA
    POULTRY SCIENCE, 1995, 74 (07) : 1191 - 1200
  • [6] ANALYSIS OF VIABILITY AND CELL-TYPES OF MACROALGAL PROTOPLASTS USING FLOW-CYTOMETRY
    COURY, DA
    BRZEZINSKI, MA
    POLNEFULLER, M
    GIBOR, A
    JOURNAL OF APPLIED PHYCOLOGY, 1995, 7 (04) : 413 - 420
  • [7] Fluorescent probes and flow cytometry to assess rat sperm integrity and mitochondrial function
    Gravance, CG
    Garner, DL
    Miller, MG
    Berger, T
    REPRODUCTIVE TOXICOLOGY, 2001, 15 (01) : 5 - 10
  • [8] The effect of glycerol on the viability, mitochondrial function and acrosomal integrity of bovine spermatozoa
    Garner, DL
    Thomas, CA
    Gravance, CG
    REPRODUCTION IN DOMESTIC ANIMALS, 1999, 34 (05) : 399 - 404
  • [9] TIME INTERVAL GATING FOR ANALYSIS OF CELL-FUNCTION USING FLOW-CYTOMETRY
    DURACK, G
    LAWLER, G
    KELLEY, S
    RAGHEB, K
    ROTH, RA
    GANEY, P
    ROBINSON, JP
    CYTOMETRY, 1991, 12 (08): : 701 - 706
  • [10] CELL-CYCLE ANALYSIS USING FLOW-CYTOMETRY
    GRAY, JW
    DOLBEARE, F
    PALLAVICINI, MG
    BEISKER, W
    WALDMAN, F
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1986, 49 (02) : 237 - 255