TANDEM REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER UTILIZING PHOTODISSOCIATION

被引:38
|
作者
BEUSSMAN, DJ [1 ]
VLASAK, PR [1 ]
MCLANE, RD [1 ]
SEETERLIN, MA [1 ]
ENKE, CG [1 ]
机构
[1] MICHIGAN STATE UNIV,DEPT CHEM,E LANSING,MI 48824
关键词
D O I
10.1021/ac00117a021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A tandem time-of-flight (TOF) mass spectrometer has been designed to obtain complete MS/MS spectra from compounds eluting from a gas chromatograph, This application requires high spectral generation rate, unit mass resolution for both precursor selection and product spectra, and efficient ion utilization, These objectives are achieved by reflectron TOF mass separation in both stages and laser photoinduced dissociation as the ion fragmentation method, Careful timing of the laser pulse relative to ion extraction allows ions of a single m/z value up to m/z 1000 to be photodissociated while ions with adjacent m/z values are essentially unaffected, The convergent foci of the ion packet and laser pulse results in ion fragmentation efficiencies as high as 79%, An ion gate prevents the nonselected precursor ions from convoluting the product spectra, Product spectra can be generated at the maximum laser repetition rate (currently 200 Hz), To achieve unit mass resolution for all product m/z values simultaneously, a novel reflectron was designed for the second TOF stage.
引用
收藏
页码:3952 / 3957
页数:6
相关论文
共 50 条
  • [1] REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER FOR LASER PHOTODISSOCIATION
    CORNETT, DS
    PESCHKE, M
    LAIHING, K
    CHENG, PY
    WILLEY, KF
    DUNCAN, MA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2177 - 2186
  • [2] PHOTODISSOCIATION AND ION SPECTROSCOPY IN A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    DUNCAN, MA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 101 - ANYL
  • [3] A DUAL-REFLECTRON TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    CORNISH, TJ
    COTTER, RJ
    TIME-OF-FLIGHT MASS SPECTROMETRY, 1994, 549 : 95 - 107
  • [4] CONVERTING A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER INTO A TANDEM INSTRUMENT
    HABERLAND, H
    KORNMEIER, H
    LUDEWIGT, C
    RISCH, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (10): : 2368 - 2371
  • [5] CLUSTER-ION PHOTODISSOCIATION AND SPECTROSCOPY IN A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    WILLEY, KF
    ROBBINS, DL
    YEH, CS
    DUNCAN, MA
    TIME-OF-FLIGHT MASS SPECTROMETRY, 1994, 549 : 61 - 72
  • [6] TANDEM TIME-OF-FLIGHT MASS-SPECTROMETRY - A MAGNETIC-SECTOR REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    STROBEL, FH
    RUSSELL, DH
    TIME-OF-FLIGHT MASS SPECTROMETRY, 1994, 549 : 73 - 94
  • [7] TANDEM SECTOR TIME-OF-FLIGHT MASS-SPECTROMETER WITH A CURVED-FIELD REFLECTRON
    COTTER, RJ
    CORNISH, TJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (04) : 339 - 340
  • [8] PHOTODISSOCIATION OF MAGNESIUM-ION MOLECULE COMPLEXES IN A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    YEH, CS
    WILLEY, KF
    ROBBINS, DL
    DUNCAN, MA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 307 - 317
  • [9] TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    CORNISH, TJ
    COTTER, RJ
    ANALYTICAL CHEMISTRY, 1993, 65 (08) : 1043 - 1047
  • [10] A TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    JARDINE, DR
    MORGAN, J
    ALDERDICE, DS
    DERRICK, PJ
    ORGANIC MASS SPECTROMETRY, 1992, 27 (10): : 1077 - 1083