REPEATABILITY OF CORNEAL TOPOGRAPHY - THE CORNEAL FIELD

被引:0
|
作者
ZADNIK, K
FRIEDMAN, NE
MUTTI, DO
机构
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND: The purpose of this study was to determine the interoccasion repeatability of keratometry, photokeratography, and videokeratography and to describe the ''corneal field,'' a scheme for explaining videokeratography results. METHODS: A single examiner obtained corneal curvature measurements with a keratometer, a photokeratoscope, and the TMS-1 in 29 adult patients on two occasions. RESULTS: Estimates for the repeatability of keratometry were +/- 0.49 and +/- 0.65 diopters (D) for the horizontal and vertical meridians respectively. The repeatability of photokeratography was +/- 0.90 and +/- 1.21 D. We presented a rational method for presenting numeric videokeratographic data by temporally and spatially averaging corneal curvature values and grouping them into 24 regions. The repeatability of videokerategraphy with the TMS-1 was +/- 0.50 D centrally, +/- 0.65 D paracentrally, and +/- 0.80 to +/- 1.00 D in the midperiphery. CONCLUSIONS: Repeatability of the photokeratoscope for central measurements is considerably worse than the keratometer. The repeatability of videokeratography is worse toward the periphery. Refractive surgeons and contact lens investigators need to be aware of these limitations so that true change can be distinguished from measurement error.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [1] REPEATABILITY OF CORNEAL TOPOGRAPHY - THE CORNEAL FIELD, (VOL 11, PG 120, 1995)
    ZADNIK, K
    [J]. JOURNAL OF REFRACTIVE SURGERY, 1995, 11 (03): : 164 - 164
  • [2] Accuracy and repeatability of the Orbscan corneal topography system.
    Beyrouthy, M
    Brunette, I
    Horner, D
    Munger, R
    Demers, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S895 - S895
  • [3] Repeatability of corneal first-surface wavefront aberrations measured with Pentacam corneal topography
    Shankar, Hema
    Taranath, Deepa
    Santhirathelagan, Chandramalar T.
    Pesudovs, Konrad
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 727 - 734
  • [4] Repeatability of Placido-Based Corneal Topography in Keratoconus
    Ortiz-Toquero, Sara
    Rodriguez, Guadalupe
    de Juan, Victoria
    Martin, Raul
    [J]. OPTOMETRY AND VISION SCIENCE, 2014, 91 (12) : 1467 - 1473
  • [5] Factors affecting repeatability of peripheral corneal topography measures
    Cervino, A
    Gonzalez-Meijome, JM
    Queiros, A
    Jorge, J
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] Repeatability of peripheral (near-limbal) corneal thickness measurements of Pentacam Scheimpflug corneal topography
    Martin, Raul
    Jonuscheit, Sven
    Doughty, Michael
    del Rio San Cristobal, Ana
    Mackintosh, Lisa
    MacTaggart, David
    Hiscock, Michael
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [7] The repeatability of corneal topography measurements in severe Dry Eye disease
    Soner Guven
    [J]. BMC Ophthalmology, 22
  • [8] Repeatability of corneal topography measurement in keratoconus with the TMS-1
    Mcmahon, TT
    Anderson, RJ
    Roberts, C
    Mahmoud, AM
    Szczotka-Flynn, LB
    Raasch, TW
    Friedman, NE
    Davis, LJ
    [J]. OPTOMETRY AND VISION SCIENCE, 2005, 82 (05) : 405 - 415
  • [9] The repeatability of corneal topography measurements in severe Dry Eye disease
    Guven, Soner
    [J]. BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [10] Repeatability of Oculus Pentacam Metrics Derived From Corneal Topography
    Miranda, Marco A.
    Radhakrishnan, Hema
    O'Donnell, Clare
    [J]. CORNEA, 2009, 28 (06) : 657 - 666