BEAT-TO-BEAT MORPHOLOGIC VARIABILITY OF THE ELECTROCARDIOGRAM FOR THE EVALUATION OF CHEST PAIN IN THE EMERGENCY ROOM

被引:8
|
作者
BENHAIM, SA
GIL, A
EDOUTE, Y
机构
[1] TECHNION ISRAEL INST TECHNOL,BRUCE RAPPAPORT FAC MED,RAPPAPORT FAMILY INST RES MED SCI,HAIFA,ISRAEL
[2] RAMBAM MED CTR,DEPT MECH & AEROSP ENGN,HAIFA,ISRAEL
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1992年 / 70卷 / 13期
关键词
D O I
10.1016/0002-9149(92)90044-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The value of electrocardiographic, morphologic variability in the early diagnosis of acute myocardial infarction (AMI) and myocardial ischemia was evaluated in 49 nonselected patients presenting to the emergency room with chest pain. High-resolution electrocardiography was used to determine the morphologic variability of consecutive electrocardiographic complexes, and the ratio of the variance of the QRS onset to that of the entire electrocardiogram was calculated. A final diagnosis of AMI was confirmed in 8 patients, acute coronary insufficiency in 8, angina pectoris in 19, and a noncardiac origin for chest pain in 14. Patients with AMI had a significantly higher beat-to-beat electrocardiographic morphologic variability of the QRS onset (1.4 +/- 0.2) than did those with acute coronary insufficiency (1.1 +/- 0.2), angina pectoris (0.9 +/- 0.1) or noncardiac chest pain (0.8 +/- 0.1) (p<0.05). The sensitivity of the clinical presentation, typical electrocardiographic changes and creatine phosphokinase levels for the diagnosis of an acute ischemic event on admission to the emergency room was 62, 25 and 37.5%, respectively. Relative variance of the QRS onset of >0.86 had a sensitivity of 75% and a specificity of 61% for diagnosing an acute ischemic event. Logistic regression of these variables showed that the QRS onset relative variability is an independent predictor for an acute ischemic event. It is concluded that an increased beat-to-beat electrocardiographic variability in patients with AMI is present on admission to the emergency room and may assist in establishing the diagnosis in this setting.
引用
收藏
页码:1139 / 1142
页数:4
相关论文
共 50 条
  • [1] Vectorcardiographic loop alignment and morphologic beat-to-beat variability
    Signal Processing Group, Department of Applied Electronics, S-221 Lund, Sweden
    不详
    IEEE Trans. Biomed. Eng., 12 (1401-1413):
  • [2] Vectorcardiographic loop alignment and morphologic beat-to-beat variability
    Sornmo, L
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (12) : 1401 - 1413
  • [3] BEAT-TO-BEAT INTERVAL MEASUREMENT IN THE ELECTROCARDIOGRAM
    KOELEMAN, ASM
    ROS, HH
    VANDENAKKER, TJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (03) : 213 - 219
  • [4] VCG loop alignment, morphologic beat-to-beat variability and the presence of noise
    Carro, E
    Åström, M
    Sörnmo, L
    Wohlfart, B
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 278 - 279
  • [5] Beat-to-beat determinants of the beat-to-beat temporal and spatial variability of repolarization
    Feeny, Albert
    Tereshchenko, Larisa G.
    JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (03) : 417 - 422
  • [6] Support system for classification of beat-to-beat arrhythmia based on variability and morphology of electrocardiogram
    Jonathan Araujo Queiroz
    Luana Monteiro Anaisse Azoubel
    Allan Kardec Barros
    EURASIP Journal on Advances in Signal Processing, 2019
  • [7] Support system for classification of beat-to-beat arrhythmia based on variability and morphology of electrocardiogram
    Queiroz, Jonathan Araujo
    Anaisse Azoubel, Luana Monteiro
    Barros, Allan Kardec
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2019, 2019 (1)
  • [8] Vectorcardiographic loop alignment and the measurement of morphologic beat-to-beat variability in noisy signals
    Åström, M
    Santos, EC
    Sörnmo, L
    Laguna, P
    Wohlfart, B
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (04) : 497 - 506
  • [9] Beat-to-beat variability of QRS duration
    Hoher, M
    Ritscher, DE
    Bauer, S
    Kodler, M
    Kestler, HA
    Hombach, V
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 613 - 616
  • [10] BEAT-TO-BEAT VARIABILITY OF VENTRICULAR LATE POTENTIALS IN THE UNAVERAGED HIGH-RESOLUTION ELECTROCARDIOGRAM
    HOHER, M
    AXMANN, J
    SAUER, H
    WEISMULLER, P
    KOCHS, M
    HOMBACH, V
    CIRCULATION, 1992, 86 (04) : 321 - 321