CONTINUOUS MONITORING OF BLOOD-GASES AND HYDROGEN-IONS WITH FIBER OPTIC CHEMICAL SENSORS (GAS-STAT) DURING HYPOTHERMIC CARDIOPULMONARY BYPASS

被引:0
|
作者
RASMUSSEN, JP
GOTHGEN, IH
SIGGAARDANDERSEN, O
WIMBERLEY, PD
FOGHANDERSEN, N
机构
[1] HERLEV HOSP,DEPT CLIN CHEM,DK-2730 HERLEV,DENMARK
[2] GENTOFTE HOSP,DEPT ANESTHESIA,DK-2900 COPENHAGEN,DENMARK
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:117 / 117
页数:1
相关论文
共 7 条
  • [1] FIBER-OPTIC CHEMICAL SENSORS (GAS-STAT) FOR BLOOD-GAS MONITORING DURING HYPOTHERMIC EXTRACORPOREAL-CIRCULATION
    GOTHGEN, IH
    SIGGAARDANDERSEN, O
    RASMUSSEN, JP
    WIMBERLEY, PD
    FOGHANDERSEN, N
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1987, 47 : 27 - 29
  • [2] EVALUATION OF THE GAS-STAT FLUORESCENCE SENSORS FOR CONTINUOUS MEASUREMENT OF PH, PCO2 AND PO2 DURING CARDIOPULMONARY BYPASS AND HYPOTHERMIA
    SIGGAARDANDERSEN, O
    GOTHGEN, IH
    WIMBERLEY, PD
    RASMUSSEN, JP
    FOGHANDERSEN, N
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1988, 48 : 77 - 84
  • [3] Continuous intra-jugular venous blood-gas monitoring with the Paratrend 7 during hypothermic cardiopulmonary bypass
    Endoh, H
    Honda, T
    Oohashi, S
    Nagata, Y
    Shibue, C
    Shimoji, K
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) : 223 - 228
  • [4] CONTINUOUS ARTERIAL AND VENOUS-BLOOD GAS MONITORING DURING CARDIOPULMONARY BYPASS
    MARK, JB
    FITZGERALD, D
    FENTON, T
    FOSBERG, AM
    CAMANN, W
    MAFFEO, N
    WINKELMAN, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (03): : 431 - 439
  • [5] Continuous monitoring of jugular venous bulbar blood gas during hypothermic cardiopulmonry bypass with Paratrend 7
    Endoh, H
    Honda, T
    Komura, N
    Sibue, C
    Ohashi, S
    ANESTHESIOLOGY, 1999, 91 (3A) : U284 - U284
  • [6] Jugular Venous Oxygenation During Hypothermic Cardiopulmonary Bypass in Patients at Risk for Abnormal Cerebral Autoregulation: Influence of α-Stat Versus pH-Stat Blood Gas Management
    Hoover, Lance R.
    Dinavahi, Radhika
    Cheng, Wei-Ping
    Cooper, John R., Jr.
    Marino, Maria Rosa
    Spata, Tyler C.
    Daniels, Gaile L.
    Vaughn, William K.
    Nussmeier, Nancy A.
    ANESTHESIA AND ANALGESIA, 2009, 108 (05): : 1389 - 1393
  • [7] CLINICAL-EVALUATION CONTINUOUS REAL-TIME INTRAARTERIAL BLOOD-GAS MONITORING DURING ANESTHESIA AND SURGERY BY FIBER OPTIC SENSOR
    SMITH, BE
    KING, PH
    SCHLAIN, L
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1992, 9 (01): : 45 - 52