WATER-QUALITY CONTROL IN THE PRODUCTION OF DRINKING-WATER FROM RIVER WATER - THE APPLICATION OF IMMUNOLOGICAL TECHNIQUES FOR THE DETECTION OF CHLOROPHENOXY ACID HERBICIDES (2,4-D)

被引:28
|
作者
MEULENBERG, EP [1 ]
STOKS, PG [1 ]
机构
[1] WRK,DIV WATER QUAL,NIEUWEGEIN,NETHERLANDS
关键词
IMMUNOASSAY; BIOSENSORS; GAS CHROMATOGRAPHY; ENVIRONMENTAL ANALYSIS; WATER QUALITY CONTROL; HERBICIDES; WATERS;
D O I
10.1016/0003-2670(95)00123-H
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the production of drinking water from river water, the quality of the raw water is extremely important. For this reason the Water Transport Company Rhine-Kennemerland (WRK) operates, among others, an early warning system. This system was found to be inappropriate for the detection of certain chlorophenoxy herbicides (e.g., 2,4-D, MCPP, MCPA and 2,4-DP) that are occasionally found in the Rhine in increased levels (above the drinking water norm of 0.1 mu g l(-1)). Commercially available immunoassay kits were evaluated for use in pre-screening. With some modifications to adapt the working range and to enhance the sensitivity of the kits, they were found to be applicable in the early warning. Comparison with a gas chromatography-mass spectrometry reference analysis revealed no false negative results and a rate of false positive results of about 10%. However, it should be taken into account that matrix effects may affect the results. A daily sampling frequency combined with an analysis frequency based on the actual flow in the river allowed for a periodic batchwise analysis. This permitted a timely availability of the results as well as a cost-effective use of the (modified) kits.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 50 条