CAN COLONY SIZE BE USED TO DETECT LOW-DOSE EFFECTS

被引:10
|
作者
SPADINGER, I [1 ]
MARPLES, B [1 ]
MATTHEWS, J [1 ]
SKOV, K [1 ]
机构
[1] BRITISH COLUMBIA CANC RES CTR,DEPT MED BIOPHYS,VANCOUVER V5Z 1L3,BC,CANADA
关键词
D O I
10.2307/3578753
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Many insults at low doses are defined as nontoxic, even though obvious effects do occur. Among these are changes in colony size when clonogenic survival is assessed. Early attempts to quantify radiation effects on colony size have been reported, but the time-consuming nature of these experiments did not encourage the use of this parameter as an end point. Recently, however, developments in image cytometry technology have provided alternative, less labor-intensive means of measuring colony size. These techniques have been used in our ongoing investigations of radiation effects at low doses. Data accumulated to date show a measurable dose dependence of colony size in clones classed as survivors. This dose dependence is characterized by fluctuations in the 0-1.5-Gy dose range, followed by a gradual decrease in colony size at higher doses. The fluctuations at low doses correspond qualitatively to the concavity, thought to be indicative of inducible repair phenomena, that has been observed in cell survival curves in the same dose range. This concavity was also seen in the current study, but its detection appeared to be dependent on the method used to score survivors.
引用
收藏
页码:S21 / S24
页数:4
相关论文
共 50 条
  • [1] CAN RESULTS FROM ANIMAL STUDIES BE USED TO ESTIMATE DOSE OR LOW-DOSE EFFECTS IN HUMANS
    THOMAS, JM
    EBERHARDT, LL
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1983, 10 (01): : 47 - 47
  • [2] Power to Detect Vaccine Effects in Repeated Low-Dose Challenge Experiments
    Hudgens, M. G.
    Wu, C.
    Gilbert, P. B.
    Self, S. G.
    Mascola, J.
    Barouch, D. H.
    AIDS RESEARCH AND HUMAN RETROVIRUSES, 2008, 24 : 40 - 40
  • [4] Non-contrast low-dose CT can be used for volumetry of ADPKD
    Jaeyeong Yoo
    Jin up Kim
    Jisu Kim
    Sohyun Jeon
    Young-jin Song
    Kwang-ho Choi
    Seok-hyung Kim
    Jong-woo Yoon
    Hyunsuk Kim
    BMC Nephrology, 24
  • [5] Non-contrast low-dose CT can be used for volumetry of ADPKD
    Yoo, Jaeyeong
    Kim, Jin Up
    Kim, Jisu
    Jeon, Sohyun
    Song, Young-jin
    Choi, Kwang-ho
    Kim, Seok-hyung
    Yoon, Jong-woo
    Kim, Hyunsuk
    BMC NEPHROLOGY, 2023, 24 (01)
  • [6] Low-Dose Irradiation Can be Used as a Phytosanitary Treatment for Fresh Table Grapes
    Kim, Gina C.
    Rakovski, Cyril
    Caporaso, Fred
    Prakash, Anuradha
    JOURNAL OF FOOD SCIENCE, 2014, 79 (01) : S81 - S91
  • [7] Can low-dose dexamethasone be used instead of prednisolone in acute asthma attacks?
    Wallace, Susan
    Chan, Nigel I. J.
    Makrinioti, Heidi
    Phillips, Bob
    ARCHIVES OF DISEASE IN CHILDHOOD, 2021, 106 (05) : 509 - +
  • [8] Low-dose effects
    Hogue, C
    CHEMICAL & ENGINEERING NEWS, 2004, 82 (14) : 50 - 54
  • [9] Power to Detect the Effects of HIV Vaccination in Repeated Low-Dose Challenge Experiments
    Hudgens, Michael G.
    Gilbert, Peter B.
    Mascola, John R.
    Wu, Chih-Da
    Barouch, Dan H.
    Self, Steven G.
    JOURNAL OF INFECTIOUS DISEASES, 2009, 200 (04): : 609 - 613
  • [10] LOW-DOSE RADIATION EFFECTS
    LIU, SZ
    CHINESE MEDICAL JOURNAL, 1994, 107 (06) : 403 - 404