Comparability of Results between Point-of-Care and Automated Instruments to Measure B-type Natriuretic Peptide

被引:0
|
作者
Shah, Kevin [1 ]
Terracciano, Garrett J. [2 ]
Jiang, Kevin [1 ]
Maisel, Alan S. [1 ,2 ]
Fitzgerald, Robert L. [2 ,3 ]
机构
[1] Vet Adm San Diego Healthcare Syst, Cardiol, La Jolla, CA USA
[2] Univ Calif San Diego, San Diego Sch Med, La Jolla, CA USA
[3] VA San Diego Healthcare Syst, Pathol, La Jolla, CA USA
关键词
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Heart failure is one of the leading causes of death in the U.S. The incorporation of B-type natriuretic peptide (BNP) measurements when triaging patients presenting with shortness of breath has improved the diagnostic and prognostic ability of physicians. Currently, there are no point-of-care systems for quantifying BNP that can be used without sacrificing accuracy. We compared the analytical performance of the Abbott i-STAT analyzer, a handheld point-of-care system for measuring BNP, with the lab-based system, the Abbott ARCHITECT. Methods: One-hundred fifty samples were collected from three clinical settings: 41 from the Emergency Department, 58 from the inpatient wards, and 51 from heart failure outpatient clinics. Linear regression and bias difference analyses were run to evaluate the accuracy of the i-STAT. Correlation between the i-STAT and Architect BNP values were made with values of BNP. Results: The correlation coefficient was r=0.977 (N=150, p<.0001). The average bias was significant (-36) and there were concentration-dependent differences at higher BNP values. Precision of the i-STAT was poor compared to the lab-based platform. Conclusion: Although the precision of the i-STAT was poor, there was good clinical agreement between the i-STAT and the lab-based platform.
引用
收藏
页码:44 / 48
页数:5
相关论文
共 50 条
  • [1] Comparison of a fully automated immunoassay with a point-of-care testing method for B-type natriuretic peptide
    Prontera, C
    Storti, S
    Emdin, M
    Passino, C
    Zyw, L
    Zucchelli, GC
    Clerico, A
    [J]. CLINICAL CHEMISTRY, 2005, 51 (07) : 1274 - 1276
  • [2] COMPARISON OF THE DIAGNOSTIC CHARACTERISTICS OF TWO B-TYPE NATRIURETIC PEPTIDE POINT-OF-CARE DEVICES
    Ro, Richard
    Thode, Henry C., Jr.
    Taylor, Maria
    Gulla, Janet
    Tetrault, Ellen
    Singer, Adam J.
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2011, 41 (06): : 661 - 667
  • [3] Point-of-Care Testing for B-type Natriuretic Peptide in Premature Neonates with Patent Ductus Arteriosus
    Kalra, Vaneet K.
    DeBari, Vincent A.
    Zauk, Adel
    Kataria, Preetika
    Myridakis, Dorothy
    Kiblawi, Fuad
    [J]. ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2011, 41 (02): : 131 - 137
  • [4] A rapid, quantitative point-of-care assay system for the measurement of B-type natriuretic peptide in blood.
    McPherson, PH
    Sundquist, AR
    Anderberg, JM
    Lesefko, SM
    Nakamura, KK
    Buechler, JA
    Valkirs, GE
    Bruni, JF
    Buechler, KF
    [J]. CLINICAL CHEMISTRY, 2000, 46 (06) : A84 - A84
  • [5] Prognostic Implications of Point-of-Care and Serial B-type Natriuretic Peptide Levels in Patients With Hypertrophic Cardiomyopathy
    Siriwardena, Maithri
    Bagai, Akshay
    Delgado, Diego
    Ross, Heather J.
    Rozenblyum, Evelyn
    Rakowski, Harry
    Woo, Anna
    Thavendiranathan, Paaladinesh
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (08): : 1421 - 1428
  • [6] Comparison of a point-of-care method to measure B-type Natiuretic Peptide (BNP) levels with an automated instrument in patients with congestive heart failure
    Jiang, K.
    Shah, K.
    Terracciano, G.
    Bhamre, S.
    Pentova, E.
    Treister, J.
    Baja, D.
    Chiu, A.
    Maisel, A.
    Fitzgerald, R.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : A199 - A199
  • [7] Clinical evaluation of a B-type natriuretic peptide point-of-care assay for the diagnosis of mild heart failure.
    Hammerer-Lercher, AM
    Ludwig, W
    Müller, S
    Neubauer, E
    Puschendorf, B
    Pachinger, O
    Mair, J
    [J]. CLINICAL CHEMISTRY, 2002, 48 (06) : A95 - A96
  • [8] B-Type Natriuretic Peptide as a Significant Brain Biomarker for Stroke Triaging Using a Bedside Point-of-Care Monitoring Biosensor
    Harpaz, Dorin
    Seet, Raymond C. S.
    Marks, Robert S.
    Tok, Alfred I. Y.
    [J]. BIOSENSORS-BASEL, 2020, 10 (09):
  • [9] Analytical performance of a single epitope B-type natriuretic peptide sandwich immunoassay on the Minicare platform for point-of-care diagnostics
    van Reenen, Alexander
    Berger, Mario
    Moreau, Emmanuel
    Bekx, Edwin
    Bruinink, Tom
    Kemper, Danielle
    van Lippen, Lian
    Weusten, Jos
    Mrakovic, Anita
    Michielsen, Etienne
    Vissers, Joost
    de Theije, Femke
    Nieuwenhuis, Jeroen
    Semjonow, Veronique
    Mair, Johannes
    [J]. PRACTICAL LABORATORY MEDICINE, 2019, 15
  • [10] B-type natriuretic peptide
    Granel, B
    [J]. REVUE DE MEDECINE INTERNE, 2004, 25 (04): : 299 - 302