A PROSPECTIVE DOUBLE-BLIND CLINICAL-TRIAL, COMPARING THE SHARP QUINCKE NEEDLE (22G) WITH AN ATRAUMATIC NEEDLE (22G) IN THE INDUCTION OF POSTLUMBAR PUNCTURE HEADACHE

被引:34
|
作者
BRAUNE, HJ
HUFFMANN, G
机构
[1] Department of Neurology, Philipps University Hospital, Marburg
来源
ACTA NEUROLOGICA SCANDINAVICA | 1992年 / 86卷 / 01期
关键词
POSTLUMBAR PUNCTURE HEADACHE; CSF LEAKAGE; SHAPE OF NEEDLE POINT; ATRAUMATIC NEEDLE;
D O I
10.1111/j.1600-0404.1992.tb08053.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Posture-dependent, post-lumbar puncture headache is most likely caused by continuous leakage of cerebrospinal fluid through the dura mater perforation with a consecutive downward sagging of the intracranial content and an irritation of pain-sensitive structures of meninges and blood vessels. A psychogenic co-factor may also play a role. It is generally acknowledged that the incidence and intensity of the headache correlate significantly with the diameter of the needles used. A second factor, the shape of the needle point plays a crucial role as is shown in our prospective, double-blind, clinical trial with 75 patients: employment of the "atraumatic" Sprotte needle with a rounded off point significantly reduced the incidence of postpuncture headache from 36% to 4%. Beside the discussion of pathogenic factors, remarks on a rational therapy are made.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 43 条
  • [1] Needle Design and the Occurence of Postdural Puncture Headache - a Randomized, Double-blind Study Comparing 22G Sprotte and Quincke
    Sjulstad, Ane Skaare
    Odeh, Francis
    Baloch, Farid Khan
    Berg, Diana Hristova
    Arntzen, Kathrine
    Alstadhaug, Karl
    NEUROLOGY, 2020, 94 (15)
  • [2] The Frequency of Post Dural Puncture Headache: Comparison of 25G Quincke Spinal Needle with 22G Whitacre
    Butt, Zulqarnain
    Ali, Maqsood
    Nazeer, Tahir
    Hussain, Riaz
    Tahir, Amna
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (04): : 1727 - 1728
  • [3] No effect of recumbency duration on the occurrence of post-lumbar puncture headache with a 22G cutting needle
    Kim, Sung R.
    Chae, Hyun S.
    Yoon, Mi J.
    Han, Jung H.
    Cho, Kwang J.
    Chung, Sun J.
    BMC NEUROLOGY, 2012, 12
  • [4] No effect of recumbency duration on the occurrence of post-lumbar puncture headache with a 22G cutting needle
    Sung R Kim
    Hyun S Chae
    Mi J Yoon
    Jung H Han
    Kwang J Cho
    Sun J Chung
    BMC Neurology, 12
  • [5] Feasibility and efficiency of a new 22G core needle: a prospective comparison study
    Hucl, Tomas
    Wee, Eric
    Anuradha, Sekaran
    Gupta, Rajesh
    Ramchandani, Mohan
    Rakesh, Kalpala
    Shrestha, Ramila
    Reddy, Duvvuru Nageshwar
    Lakhtakia, Sundeep
    ENDOSCOPY, 2013, 45 (10) : 792 - 798
  • [6] Incidence of postdural puncture headache and backache following diagnostic/therapeutic lumbar puncture using a 22G cutting spinal needle, and after introduction of a 25G pencil point spinal needle
    Lowery, Susan
    Oliver, Alexander
    PEDIATRIC ANESTHESIA, 2008, 18 (03) : 230 - 234
  • [7] 25G or 22G Needle, Which Is Better for EUS-FNA for Pancreatic Tumor? Prospective Randomized Controlled Trial
    Choi, E. Ryoung
    Jang, Tae Hoon
    Jang, Kee Taek
    Lee, Jong Kyun
    Lee, Kyu Taek
    Lee, Kwang Hyuck
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB284 - AB284
  • [8] A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions
    Camellini, L.
    Carlinfante, G.
    Azzolini, F.
    Iori, V.
    Cavina, M.
    Sereni, G.
    Decembrino, F.
    Gallo, C.
    Tamagnini, I.
    Valli, R.
    Piana, S.
    Campari, C.
    Gardini, G.
    Sassatelli, R.
    ENDOSCOPY, 2011, 43 (08) : 709 - 715
  • [9] Evaluation of New 25G Needle in EBUS-TBNA Comparing Conventional 22G Needle in Diagnosis for Nodal Metastasis of Lung Cancer
    Sakairi, Y.
    Nakajima, T.
    Yonemori, Y.
    Kaiho, T.
    Ohashi, K.
    Sata, Y.
    Shiina, Y.
    Toyoda, T.
    Hata, A.
    Tamura, H.
    Fujiwara, T.
    Wada, H.
    Suzuki, H.
    Chiyo, M.
    Yoshino, I.
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (11) : S2164 - S2164
  • [10] Traumatic vs. atraumatic 22 G needle for therapeutic and diagnostic lumbar puncture in the hematologic patient: a prospective clinical trial
    Lavi, Ronit
    Rowe, Jacob M.
    Avivi, Irit
    HAEMATOLOGICA, 2007, 92 (07) : 1007 - 1008