FREEZING TECHNIQUE AND QUALITY OF FRESH-FROZEN PLASMA

被引:0
|
作者
AKERBLOM, O [1 ]
BREMME, K [1 ]
DACKLAND, AL [1 ]
FATAH, K [1 ]
SUONTAKA, AM [1 ]
BLOMBACK, M [1 ]
机构
[1] KAROLINSKA HOSP,KEM BLODKOAGULAT KLIN,S-10401 STOCKHOLM 60,SWEDEN
来源
关键词
FRESH-FROZEN PLASMA; FREEZING TECHNIQUE; BETA-THROMBOGLOBULIN; COAGULATION FACTOR-VIII; FACTOR-V; FACTOR-VII; VONWILLEBRAND FACTOR; FIBRINOPEPTIDE-A; THROMBIN-ANTITHROMBIN COMPLEXES; SOLUBLE FIBRIN;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cell-poor plasma was prepared by apheresis from 10 donors. From each donor, an amount of 200 ml was frozen rapidly to -40-degrees-C in standard blood bags, and a further 200 ml was frozen slowly to -20-degrees-C. Before freezing and after thawing, plasma samples were collected and frozen to -70-degrees-C pending analysis. Coagulation factor VIII activity was reduced to 90% by rapid freezing and to 80% by slow freezing. Factor V was not influenced by rapid freezing, but slow freezing reduced the levels to 92% of the pre-freezing levels. In some of the plasma bags a slight increase in fibrinopeptide A occurred. However, soluble fibrin, thrombin-antithrombin complexes and spontaneous proteolytic activity were not altered by freezing. The beta-thromboglobulin increased slightly with slow freezing. Moreover, in a separate experiment, evaluating the possible effects of refreezing plasma samples, an increase in beta-thromboglobulin was also recorded, while the levels of factors VIII and V and von Willebrand factor were not affected. The changes in some variables, which were recorded in the cell-poor plasma, frozen soon after the blood donation at a slow freezing rate, must be regarded as insignificant in most clinical situations.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 50 条
  • [1] ON THE QUALITY OF FRESH-FROZEN PLASMA
    Berkovsky, A. L.
    Vatagina, E. A.
    Sergeeva, E. V.
    Suvorov, A. V.
    Aleksanyan, M. Zh.
    [J]. GEMATOLOGIYA I TRANSFUZIOLOGIYA, 2012, 57 (04): : 32 - 34
  • [2] Quality of fresh-frozen plasma during storage
    Riggert, J
    Morsdorf, S
    Pindur, G
    Kohler, M
    Seyfert, UT
    [J]. VOX SANGUINIS, 1997, 73 (04) : 257 - 257
  • [3] QUALITY ASSURANCE IN HEMAPHERESIS - QUALITY OF FRESH-FROZEN PLASMA
    BALDINI, GM
    SILVESTRI, MG
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 : 226 - 228
  • [4] A NEW HOLDER FOR FREEZING, STORAGE AND SHIPPING OF FRESH-FROZEN PLASMA
    ROWE, AW
    LENNY, LL
    STRYKER, MH
    [J]. TRANSFUSION, 1981, 21 (05) : 629 - 629
  • [5] A FRESH LOOK AT FRESH-FROZEN PLASMA
    不详
    [J]. EMERGENCY MEDICINE, 1985, 17 (04) : 117 - 120
  • [6] The effect of leucocyte depletion on the quality of fresh-frozen plasma
    Cardigan, R
    Sutherland, J
    Garwood, M
    Krailadsiri, P
    Seghatchian, J
    Beard, M
    Beckman, N
    Williamson, LM
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2001, 114 (01) : 233 - 240
  • [7] QUALITY CRITERIA IN THE PASTEURIZATION PROCESS OF FRESH-FROZEN PLASMA
    BURNOUFRADOSEVICH, M
    BURNOUF, T
    HUART, JJ
    [J]. REVUE FRANCAISE DE TRANSFUSION ET D HEMOBIOLOGIE, 1993, 36 (01): : 93 - 102
  • [8] EFFECTS OF FREEZING ON COMPLEMENT LEVELS IN FRESH-FROZEN PEDIATRIC PLASMA PACKS
    BRYANT, LR
    BEZBAK, HC
    CORKERN, SM
    RUSSO, A
    [J]. CRYOBIOLOGY, 1979, 16 (06) : 605 - 605
  • [9] COMPOSITION OF FRESH-FROZEN PLASMA
    EWALENKO, P
    DELOOF, T
    PEETERS, J
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (02) : 145 - 146
  • [10] Anaphylatoxins in fresh-frozen plasma
    Sonntag, J
    Stiller, B
    Walka, MM
    Maier, RF
    [J]. TRANSFUSION, 1997, 37 (08) : 798 - 803