NEUTRON DETECTION EFFICIENCY OF LIQUID SCINTILLATOR NE 214 IN MEV RANGE

被引:5
|
作者
KELLERMA.HJ
LANGKAU, R
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1971年 / 94卷 / 01期
关键词
D O I
10.1016/0029-554X(71)90350-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:137 / &
相关论文
共 50 条
  • [1] THE ABSOLUTE DETECTION EFFICIENCY OF AN NE 213 LIQUID SCINTILLATOR FOR NEUTRONS IN THE ENERGY-RANGE 50 - 450 MEV
    CIERJACKS, S
    SWINHOE, MT
    BUTH, L
    HOWE, SD
    RAUPP, F
    SCHMITT, H
    LEHMANN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 192 (2-3): : 407 - 413
  • [2] Analytical modeling of the neutron response function of the NE213 organic liquid scintillator in the energy range of 0.2 MeV to 148 MeV
    Pour, H. Gharaghani
    Tajik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 995
  • [3] Calibration of neutron detection efficiency for a stilbene scintillator detector in the energy range of 18-27MeV
    Wang, Xiaozhong
    Li, Anli
    Bai, Xixiang
    Liu, Weiping
    Chin, Dahai
    Yuan, Yuan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 1995, 29 (06): : 500 - 504
  • [4] CALIBRATION OF NEUTRON DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR, 1 TO 200 MEV
    EDELSTEIN, RM
    EDWARDS, KW
    ABOLINS, MA
    REAY, NW
    GILL, DR
    MILLER, EL
    THATCHER, RC
    STANTON, NR
    RUSS, JS
    LIN, MT
    ELFIELD, M
    NUCLEAR INSTRUMENTS & METHODS, 1972, 100 (02): : 355 - +
  • [5] DETECTION EFFICIENCY OF PLASTIC SCINTILLATOR FOR NEUTRON ENERGIES 4 TO 76 MEV
    WIEGAND, CE
    YPSILANTIS, T
    LACH, J
    JOHNSON, WB
    ELIOFF, T
    AUERBACH, LB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (05): : 526 - &
  • [7] Absolute measurements of the response function of an NE213 organic liquid scintillator for the neutron energy range up to 206 MeV
    Nakao, N
    Kurosawa, T
    Nakamura, T
    Uwamino, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2): : 275 - 287
  • [8] DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR FOR NEUTRONS IN THE ENERGY RANGE OF 1 TO 14 MEV
    GRASSLER, H
    TESCH, K
    NUCLEAR INSTRUMENTS & METHODS, 1961, 10 (04): : 353 - 355
  • [9] NEUTRON DETECTION EFFICIENCY OF AN ORGANIC SCINTILLATOR
    MUBARAKMAND, S
    ANWAR, M
    NUCLEAR INSTRUMENTS & METHODS, 1971, 93 (03): : 515 - +
  • [10] Measurement of response functions of organic liquid scintillator for neutron energy range up to 390 MeV
    Taniguchi, S.
    Nakao, N.
    Yamakawa, H.
    Oishi, K.
    Nakamura, T.
    Tamii, A.
    Hatanaka, K.
    Saito, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02): : 954 - 957