EFFECT OF AORTIC-VALVE REPLACEMENT ON SYNCOPE IN PATIENTS WITH AORTIC-STENOSIS

被引:0
|
作者
WILMSHURST, PT [1 ]
WILLICOMBE, PR [1 ]
WEBBPEPLOE, MM [1 ]
机构
[1] ST THOMAS HOSP,DEPT CARDIOL,LONDON,ENGLAND
来源
BRITISH HEART JOURNAL | 1993年 / 70卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To determine the role of exertion as a precipitating factor in syncope in patients with aortic stenosis. Design,-Follow up for at least one year after aortic valve replacement. Setting-Regional cardiac centre. Patients-Consecutive patients who underwent aortic valve replacement for aortic stenosis and who had a history of syncope and no other clinically significant cardiac lesion were recruited during a five year period. Methods-Patients were interviewed to determine the characteristics of syncope and were divided into those in whom syncope was consistently related to exertion (group 1, 26 patients) and those in whom it was not (group 2, 13 patients). Recurrence of syncope after valve replacement was determined at visits to the clinic. Results-Groups 1 and 2 did not differ significantly with respect to valve area, age, or sex. In 13 of the 26 patients in group 1 syncope was preceded by angina despite the absence of coronary artery disease, but none of the 13 patients in group 2 had angina. After valve replacement none of group 1 and eight of the 13 patients in group 2 had recurrence of syncope (p < 0.01). Conclusion-When patients with aortic stenosis experience syncope unrelated to exertion, the symptom is usually unrelated to the valve disease and another cause should be sought.
引用
收藏
页码:542 / 543
页数:2
相关论文
共 50 条
  • [1] THE EFFECT OF AORTIC-VALVE REPLACEMENT ON VENTRICULAR ECTOPY IN PATIENTS WITH AORTIC-STENOSIS
    KOSTIS, JB
    BABINETZ, P
    MOREYRA, A
    HOSLER, M
    AGLITZ, N
    MARANHAO, V
    GOOCH, A
    NAYAK, K
    KUO, PT
    [J]. CHEST, 1981, 80 (03) : 385 - 385
  • [2] AORTIC-VALVE REPLACEMENT IN ELDERLY PATIENTS WITH AORTIC-STENOSIS - ABSTRACTS
    STRAUMANN, E
    KIOWSKI, W
    LANGER, I
    GRADEL, E
    STULZ, P
    BURCKHARDT, D
    PFISTERER, M
    BURKART, F
    [J]. BRITISH HEART JOURNAL, 1994, 71 (05): : 449 - 453
  • [3] EVALUATION OF AORTIC-VALVE REPLACEMENT IN PATIENTS WITH VALVULAR AORTIC-STENOSIS
    HENRY, WL
    BONOW, RO
    BORER, JS
    KENT, KM
    WARE, JH
    REDWOOD, DR
    ITSCOITZ, SB
    MCINTOSH, CL
    MORROW, AG
    EPSTEIN, SE
    [J]. CIRCULATION, 1980, 61 (04) : 814 - 825
  • [4] AORTIC-VALVE REPLACEMENT IN PATIENTS WITH AORTIC-STENOSIS - EFFECT ON CARDIAC-ARRHYTHMIAS
    KOSTIS, JB
    TUPPER, B
    MOREYRA, AE
    HOSLER, M
    COSGROVE, N
    TERREGINO, C
    [J]. CHEST, 1984, 85 (02) : 211 - 214
  • [5] EMERGENCY AORTIC-VALVE REPLACEMENT FOR CRITICAL AORTIC-STENOSIS
    HOWE, JP
    COHN, LH
    DALEN, JE
    COLLINS, JJ
    [J]. CIRCULATION, 1973, 48 (04) : 155 - 155
  • [6] AORTIC DISSECTION AFTER AORTIC-VALVE REPLACEMENT IN PATIENTS WITH VALVULAR AORTIC-STENOSIS
    MUNA, WF
    SPRAY, TL
    MORROW, AG
    ROBERTS, WC
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1977, 74 (01): : 65 - 69
  • [7] AORTIC-VALVE REPLACEMENT - PROCEDURE OF CHOICE IN ELDERLY PATIENTS WITH AORTIC-STENOSIS
    PUPELLO, DF
    BESSONE, LN
    HIRO, SP
    LOPEZCUENCA, E
    GLATTERER, MS
    ANGELL, WW
    EBRA, G
    [J]. JOURNAL OF CARDIAC SURGERY, 1994, 9 (02) : 148 - 153
  • [8] AORTIC-VALVE REPLACEMENT IN PATIENTS WITH AORTIC-STENOSIS AND LOW TRANSAORTIC GRADIENT
    LIPMANN, N
    GOLDBERG, HL
    WALLIS, JB
    BORER, JS
    [J]. CLINICAL RESEARCH, 1985, 33 (02): : A206 - A206
  • [9] EFFECT OF AORTIC-VALVE REPLACEMENT FOR AORTIC-STENOSIS ON SEVERITY OF MITRAL REGURGITATION
    TUNICK, PA
    GINDEA, A
    KRONZON, I
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (18): : 1219 - 1221
  • [10] AORTIC-VALVE REPLACEMENT IN PATIENTS WITH AORTIC-STENOSIS AND LOW TRANSAORTIC GRADIENT
    LIPPMAN, N
    GOLDBERG, HL
    WALLIS, JB
    BORER, JS
    [J]. CLINICAL RESEARCH, 1984, 32 (03): : A676 - A676