NONCONTACT ABSOLUTE POSITION MEASUREMENT USING A COMPACT-DISK PLAYER OPTICAL PICK-UP

被引:12
|
作者
DURING, C
ANDERSSON, S
WILKANDER, J
机构
[1] The Royal Institute of Technology, Department of Machine Elements
关键词
D O I
10.1016/0924-4247(92)80046-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An optical pick-up from a compact disc player is used as an absolute position sensor. The output from the pick-up gives the optical reflectivity profile from an object on which the measurement is to be taken. The object's position is given from the correlation between a pre-sampled reference of the reflectivity profile and actual samples of the same profile. The method is demonstrated for position/angle measurement of a smooth hand-polished rotating aluminium disc.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 34 条
  • [1] Surface Measurement of Microstructures Using Optical Pick-up Based Scanner
    Kim, JaeHyun
    Park, Jungyul
    Lee, Seung-Yop
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2010, 34 (01) : 73 - 76
  • [2] Position tracking control of an optical pick-up device using piezoceramic actuator
    Choi, SB
    Kim, HK
    Lim, SC
    Kim, JH
    SMART STRUCTURES AND MATERIALS 2000: MATHEMATICS AND CONTROL IN SMART STRUCTURES, 2000, 3984 : 370 - 376
  • [3] Position tracking control of an optical pick-up device using piezoceramic actuator
    Choi, SB
    Kim, HK
    Lim, SC
    Park, YP
    MECHATRONICS, 2001, 11 (06) : 691 - 705
  • [4] Measurement of microthermal deformations in an optical pick-up base using holographic interferometry
    Seo, Y
    Cho, S
    Kang, SN
    OPTICAL ENGINEERING, 2003, 42 (11) : 3198 - 3203
  • [5] Stationary pick-up head for very fast seek in optical disk drives
    Glaser, I
    Glaser, R
    Meshulam, G
    ISOM/ODS 2002: INTERNATIONAL SYMPOSIUM ON OPTICAL MEMORY AND OPTICAL DATA STORAGE TOPICAL MEETING, TECHNICAL DIGEST, 2002, : 335 - 337
  • [6] Ac-loss measurement of coated conductors: The influence of the pick-up coil position
    Schmidt, Curt
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (13): : 978 - 984
  • [7] Axial Vibration Characteristics Considering a Moving Pick-Up Unit for the Flexible Optical Disk System
    Jo, Jun Hyeon
    Rhim, Yoon Chul
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (09)
  • [8] LASER-DETECTOR-HOLOGRAM UNIT FOR THIN OPTICAL PICK-UP HEAD OF A CD-PLAYER
    YOSHIKAWA, A
    NAKANISHI, H
    ITOH, K
    YAMAZAKI, T
    KOMINO, T
    MUSHA, T
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART B-ADVANCED PACKAGING, 1995, 18 (02): : 245 - 249
  • [9] Busbar current measurement in induction heating furnaces using a pick-up coil
    Tant, Peter
    Hectors, Dietrich
    Van Reusel, Koen
    Deconinck, Geert
    Driesen, Johan
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 1898 - 1903
  • [10] A new DNA chip detection mechanism using optical pick-up actuators
    Kim, Kyung-Ho
    Lee, Seung-Yop
    Kim, Sookyung
    Lee, Seung-Hwan
    Jeong, Seong-Gab
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2007, 13 (8-10): : 1359 - 1369