EVALUATION OF CONTACT RESISTANCE FOR ISOTROPIC ELECTRICALLY CONDUCTIVE ADHESIVES

被引:47
|
作者
GAYNES, MA
LEWIS, RH
SARAF, RF
ROLDAN, JM
机构
[1] IBM CORP,THOMAS J WATSON RES CTR,YORKTOWN HTS,NY 10598
[2] IBM CORP,THOMAS J WATSON RES CTR,DEPT SILICON SCI & TECHNOL,YORKTOWN HTS,NY 10598
关键词
D O I
10.1109/96.386265
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Electrically conductive adhesives are discussed and studied with ever-increasing interest as an alternative to solder interconnection in microelectronics circuit packaging, A similar level of scrutiny that is used to evaluate contact resistance performance for interconnections made with solder and separable connectors is necessary for electrically conductive adhesives. Experience with solder interconnection and separable connectors shows low initial contact resistance of less than 10 m Omega when bulk conductor material is minimized in the measurement scheme, Stability is typically determined to be less than a 5-10 m Omega change as a function of stress. The main intent of this study is to characterize the electrical contact resistance performance of joints made with isotropic electrically conductive adhesives, A copper comb pattern test vehicle was designed and fabricated using 0.25-mm thick lead frame material, The plating finishes that were applied to the copper substrate included a palladium alloy, gold, tin, and nickel, Test samples were made with several electrically conductive adhesives, Samples consisted of two comb patterns bonded to each other making a gang of 40 lap joints, Variables from circuit packaging such as coefficient of thermal expansion mismatches are purposely avoided in this study. Contact resistance measurements were made initially and as a function of time during environmental tests, Stresses included thermal cycling, thermal aging, and temperature and humidity conditioning. The stability of electrical contact resistance is shown to be influenced by both plating metallurgy and the conductive adhesive itself. Contact resistance equivalent to solder is possible with some electrically conductive adhesives on appropriate metallurgical finishes, Mechanically, adhesive joints are less robust than solder joints, and therefore care must be taken to eliminate or minimize the effects of mechanical loading.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 50 条
  • [1] Electrically isotropic conductive adhesives: An effective contact resistance model for conductivity development
    Abdullah, M
    Shi, FG
    Chungpaiboonpatana, S
    Okuyama, K
    Davidson, C
    Adams, JM
    [J]. INTERNATIONAL SYMPOSIUM ON ADVANCED PACKAGING MATERIALS: PROCESSES, PROPERTIES AND INTERFACES, PROCEEDINGS, 1999, : 282 - 287
  • [2] Drop Test Performance of Isotropic Electrically Conductive Adhesives
    Morris, James E.
    Lee, Jeahuck
    [J]. JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2008, 22 (14) : 1699 - 1716
  • [3] The effects of temperature and humidity aging on the contact resistance of novel electrically conductive adhesives
    Van Wuytswinkel, G
    Dreezen, G
    Luyckx, G
    [J]. POLYTRONIC 2002: 2ND INTERNATIONAL IEEE CONFERENCE ON POLYMERS AND ADHESIVES IN MICROELECTRONICS AND PHOTONICS, CONFERENCE PROCEEDINGS, 2002, : 225 - 230
  • [4] Low-tech studies of isotropic electrically conductive adhesives
    Morris, JE
    Anderssohn, F
    Loos, E
    Liu, J
    [J]. 26TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, CONFERENCE PROCEEDINGS: INTEGRATED MANAGEMENT OF ELECTRONIC MATERIALS PRODUCTION, 2003, : 90 - 94
  • [5] Determination of the Contact Resistance of Planar Contacts: Electrically Conductive Adhesives in Battery Cell Connections
    Jocher, Philipp
    Kick, Michael K.
    Rubio Gomez, Manuel
    Himmelreich, Adrian V.
    Gruendl, Alena
    Hoover, Edgar
    Zaeh, Michael F.
    Jossen, Andreas
    [J]. BATTERIES-BASEL, 2023, 9 (09):
  • [6] Contact resistance of anisotropic conductive adhesives
    Divigalpitiya, R
    Hogerton, P
    [J]. 2003 INTERNATIONAL SYMPOSIUM ON MICROELECTRONICS, 2003, 5288 : 471 - 476
  • [7] Reliability of Isotropic Electrically Conductive Adhesives under Condensing Humidity Testing
    Frisk, Laura
    Lahokallio, Sanna
    Mostofizadeh, Milad
    Kiilunen, Janne
    Saarinen, Kirsi
    [J]. PROCEEDINGS OF THE 2012 IEEE 14TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, 2012, : 174 - 179
  • [8] Self-alignment feasibility study and contact resistance improvement of electrically conductive adhesives (ECAs)
    Wu, JL
    Moon, K
    Wong, CP
    [J]. 51ST ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 2001, : 571 - 575
  • [9] Simultaneously Improving Electrical Properties and Stabilizing Contact Resistance of Electrically Conductive Adhesives by Using Aminoaldehydes
    Gao, Hong
    Liu, Lan
    Luo, Yuan-Fang
    Jia, De-Min
    Lu, Jia-Sheng
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE PART B-PHYSICS, 2011, 50 (10): : 1939 - 1954
  • [10] Contact Resistance and Metallurgical Connections Between Silver Coated Polymer Particles in Isotropic Conductive Adhesives
    Sigurd R. Pettersen
    Helge Kristiansen
    Shijo Nagao
    Susanne Helland
    John Njagi
    Katsuaki Suganuma
    Zhiliang Zhang
    Jianying He
    [J]. Journal of Electronic Materials, 2016, 45 : 3734 - 3743