摘要
The accuracy of body-composition measurements by dual-energy x-ray absorptiometry (DXA) was assessed by comparison with total carcass chemical analysis in 16 pigs with a weight range of 5-35 kg. Two software versions for body-composition analyses with the DXA instrument were evaluated. Although both software versions accurately predicted body weight, there were significant differences in the partitioning between bone mineral content (BMC), nonbone lean tissue, and body-fat compartments. All estimates of body composition were highly correlated (r(2) greater than or equal to 0.98) with the results of the direct chemical reference method. SEEs were 226-271 g for body weight, 387-429 g for fat, 3.5-4.3 kg for fat-free mass, and 35.4-36.5 g for BMC. For bone, both software versions produced BMC values that were approximate to 25% below the total carcass ash content. For the absolute mass of body fat, one DXA analysis provided underestimates that averaged 19.5% below the reference chemical method, whereas the alternate software version resulted in overestimates, averaging 15.5%. Conversely, the average fat-free compartment was initially overestimated by 968 g, then underestimated by 892 g. The impact of these differences in the body-composition analyses by DXA were examined in a group of 18 young boys 4-12 y of age.
引用
收藏
页码:660 / 665
页数:6
相关论文
共 50 条
  • [1] ACCURACY OF MEASUREMENTS OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY INVIVO
    SVENDSEN, OL
    HAARBO, J
    HASSAGER, C
    CHRISTIANSEN, C
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (05): : 605 - 608
  • [2] ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) FOR BODY-COMPOSITION MEASUREMENTS IN PEDIATRIC STUDIES
    ELLIS, K
    SHYPAILO, R
    PRATT, J
    MERSMANN, H
    POND, W
    [J]. FASEB JOURNAL, 1993, 7 (03): : A359 - A359
  • [3] BODY-COMPOSITION IN CHILDREN AND TANNERS STAGES - A STUDY WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    RICO, H
    REVILLA, M
    VILLA, LF
    HERNANDEZ, ER
    DEBUERGO, MA
    VILLA, M
    [J]. METABOLISM-CLINICAL AND EXPERIMENTAL, 1993, 42 (08): : 967 - 970
  • [4] DETECTION OF SMALL CHANGES IN BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOING, SB
    MASSETT, MP
    HALL, MC
    BARE, LA
    ROOT, PA
    WILLIAMS, DP
    LOHMAN, TG
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06): : 845 - 850
  • [5] Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in rats
    Bertin, E
    Ruiz, JC
    Mourot, J
    Peiniau, P
    Portha, B
    [J]. JOURNAL OF NUTRITION, 1998, 128 (09): : 1550 - 1554
  • [6] DETERMINATION OF BODY-COMPOSITION - A COMPARISON OF DUAL-ENERGY X-RAY ABSORPTIOMETRY AND HYDRODENSITOMETRY
    JOHANSSON, AG
    FORSLUND, A
    SJODIN, A
    MALLMIN, H
    HAMBRAEUS, L
    LJUNGHALL, S
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (03): : 323 - 326
  • [7] COMPARATIVE-STUDY OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    ALOIA, JF
    VASWANI, A
    MA, RM
    FLASTER, E
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (08): : 1392 - 1397
  • [8] Accuracy and precision of dual-energy X-ray absorptiometry for body composition measurements in rhesus monkeys
    Black, A
    Tilmont, EM
    Baer, DJ
    Rumpler, DK
    Roth, GS
    Lane, MA
    [J]. JOURNAL OF MEDICAL PRIMATOLOGY, 2001, 30 (02) : 94 - 99
  • [9] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    [J]. NUTRITION, 1996, 12 (01) : 45 - 51
  • [10] Dual-energy X-ray absorptiometry and body composition
    Plank, LD
    [J]. CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (03): : 305 - 309