REFERENCE THRESHOLD LEVELS FOR THE ER-3A INSERT EARPHONE

被引:0
|
作者
WILBER, LA
KRUGER, BA
KILLION, MC
机构
[1] NORTHWESTERN UNIV,PROGRAM AUDIOL,EVANSTON,IL 60202
[2] KRUGER ASSOCIATES,COMMACK,NY 11725
[3] ETYMOT RES,ELK GROVE VILLAGE,IL 60007
关键词
D O I
10.1121/1.2024389
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
引用
收藏
页码:S75 / S76
页数:2
相关论文
共 50 条
  • [1] Reference hearing threshold levels for chirp signals delivered by an ER-3A insert earphone
    Gotsche-Rasmussen, Kristian
    Poulsen, Torben
    Elberling, Claus
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2012, 51 (11) : 794 - 799
  • [2] REFERENCE THRESHOLDS FOR THE ER-3A INSERT EARPHONE
    WILBER, LA
    KRUGER, B
    KILLION, MC
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (02): : 669 - 676
  • [3] A comparison of inter-aural attenuation with the Etymotic ER-3A insert earphone and the Telephonics TDH-39 supra-aural earphone
    Munro, KJ
    Agnew, N
    BRITISH JOURNAL OF AUDIOLOGY, 1999, 33 (04): : 259 - 262
  • [4] REFERENCE THRESHOLD SOUND-PRESSURE LEVELS FOR THE TDH-50 AND ER-3A EARPHONES
    LARSON, VD
    COOPER, WA
    TALBOTT, RE
    SCHWARTZ, DM
    AHLSTROM, C
    DECHICCHIS, AR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (01): : 46 - 51
  • [5] REFERENCE EQUIVALENT THRESHOLD LEVELS FOR PURE-TONES AND 1/3-OCT NOISE BANDS - INSERT EARPHONE AND TDH-49 EARPHONE
    COX, RM
    MCDANIEL, DM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1986, 79 (02): : 443 - 446
  • [6] A Version of the TEN Test for Use With ER-3A Insert Earphones
    Moore, Brian C. J.
    Creeke, Sarah
    Glasberg, Brian R.
    Stone, Michael A.
    Sek, Aleksander
    EAR AND HEARING, 2012, 33 (04): : 554 - 557
  • [7] Effects of aging on ocular vestibular-evoked myogenic potential using ER-3A insert earphone and B81 bone vibrator
    Xu, Zhuo
    Wang, Zhilin
    Zhong, Bo
    Wang, Minjiao
    Fan, Xiaoqin
    Ren, Cuncun
    Qi, Meihao
    Lin, Ying
    Zha, Dingjun
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [8] 3 STUDIES COMPARING PERFORMANCE OF THE ER-3A TUBEPHONE WITH THE TDH-50P EARPHONE
    CLARK, JL
    ROESER, RJ
    EAR AND HEARING, 1988, 9 (05): : 268 - 274
  • [9] NORMAL HEARING THRESHOLD LEVELS IN THE LOW-FREQUENCY RANGE DETERMINED BY AN INSERT EARPHONE
    ARLINGER, SD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (05): : 2411 - 2414
  • [10] Equivalent threshold sound pressure levels for Sennheiser HDA 200 earphone and Etymotic Research ER-2 insert earphone in the Frequency range 125 Hz to 16 kHz
    Han, LA