VERIFICATION OF THE SEISMIC RESISTANCE OF GAS-INSULATED SWITCHGEAR (GIS)

被引:3
|
作者
BUCK, KE
KLEINETEBBE, A
REES, V
机构
[1] HOCHTEMPERATUR REAKTORBAU,JULICH,GERMANY
[2] ABB SCHALTANLAGEN GMBH,MANNHEIM,GERMANY
关键词
GIS; EARTHQUAKE; SEISMIC QUALIFICATION;
D O I
10.1109/61.180326
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
After a brief introduction into the background of seismic requirements the- paper describes the test procedures, demonstrating the capability of gas insulated switchgear to withstand seismic stresses up to highest ground accelerations of 0.75 g. The verification methods for checking the test object after test are described also. As vibrational tests are very cost intensive and therefore can only be performed with a representative switchgear arrangement, calculation methods for demonstrating the seismic withstand behaviour of practical switchgear arrangements are needed. A calculation model will be described, adopted to the results of the representative seismic tests. The tests and calculation results demonstrate the suitability of a 3pole common enclosed GIS design for 145/170 kV for horizontal ground accelerations up to 0.75 g.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [1] GAS-INSULATED SWITCHGEAR AND INTERRUPTER
    HAYASHI, K
    YAMAUCHI, T
    MARUTANI, T
    SASAMORI, K
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1986, 21 (06): : 975 - 979
  • [2] GAS-INSULATED SWITCHGEAR.
    Marutani, Tomohiro
    Onuma, Akiyoshi
    [J]. Mitsubishi Electric Advance, 1987, 39 : 16 - 18
  • [3] GAS-INSULATED SWITCHGEAR AND INTERRUPTER.
    Hayashi, K.
    Yamauchi, T.
    Marutani, T.
    Sasamori, K.
    [J]. IEEE transactions on electrical insulation, 1986, EI-21 (06): : 975 - 979
  • [4] TESTING METHODS FOR GAS-INSULATED SWITCHGEAR
    YAMAUCHI, T
    OGAWA, A
    YAMAMARU, M
    KATO, T
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1986, 21 (06): : 1065 - 1068
  • [5] Two Planar Antennas for Detection of Partial Discharge in Gas-Insulated Switchgear (GIS)
    Lozano-Claros, Diego
    Custovic, Eddie
    Elton, Darrell
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATION, NETWORKS AND SATELLITE (COMNESTAT), 2015, : 8 - 15
  • [6] TESTING METHODS FOR GAS-INSULATED SWITCHGEAR.
    Yamauchi, T.
    Ogawa, A.
    Yamamaru, M.
    Kato, T.
    [J]. 1600, (EI-21):
  • [7] Highly integrated and compact Gas-Insulated Switchgear (GIS) for 4000A and 63 kA
    Betz, T
    Braun, T
    Peters, H
    Heinemann, L
    Rees, V
    [J]. 2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 450 - 455
  • [8] DEVELOPMENT OF 800KV GAS-INSULATED SWITCHGEAR
    TODA, H
    OZAKI, Y
    MIWA, I
    NISHIWAKI, S
    MURAYAMA, Y
    YANABU, S
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) : 316 - 323
  • [9] Assessment of PD severity in gas-insulated switchgear with an SSAE
    Tang, Ju
    Jin, Miao
    Zeng, Fuping
    Zhang, Xiaoxing
    Huang, Rui
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2017, 11 (04) : 423 - 430
  • [10] TECHNIQUES AND INSTRUMENTATION FOR MEASUREMENT OF TRANSIENTS IN GAS-INSULATED SWITCHGEAR
    BOGGS, SA
    FUJIMOTO, N
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1984, 19 (02): : 87 - 92