QUANTITATION USING BENZENE IN GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY

被引:18
|
作者
ALLGOOD, C [1 ]
MA, YC [1 ]
MUNSON, B [1 ]
机构
[1] UNIV DELAWARE,DEPT CHEM & BIOCHEM,NEWARK,DE 19716
关键词
D O I
10.1021/ac00007a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dilute mixtures of benzene in helium provide abundant C6H6.+ ions, which selectively react by charge transfer under chemical ionization (CI) conditions with unsaturated compounds in complex hydrocarbon mixtures and do not react with alkanes or cycloalkanes. The charge-transfer spectra from the ion/molecule reactions of C6H6.+ are very simple, containing essentially only M.+ ions from the samples. Relative molar sensitivities for olefins and alkylbenzenes in benzene chemical ionization mass spectrometry (CIMS) are essentially constant within +/- 10-15%, independent of molecular weight in the range of 100-200 Da, molecular structure, the degree of substitution, or ionization energy. The relative molar sensitivities in benzene CIMS show much loss variation with molecular structure than relative molar sensitivities in low-voltage electron ionization mass spectrometry (LV-EIMS). GC/CIMS with benzene as the charge-transfer reagent gas allows quantitative analyses of the aromatic and olefinic components in gasolines or other complex hydrocarbon mixtures without the necessity of calibration curves for the individual components.
引用
收藏
页码:721 / 725
页数:5
相关论文
共 50 条
  • [1] QUANTITATION OF PLASMA WARFARIN LEVELS BY GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY
    DUFFIELD, PH
    BIRKETT, DJ
    WADE, DN
    DUFFIELD, AM
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (03): : 101 - 104
  • [2] NEUTRAL REACTIONS IN GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY
    RUDEWICZ, P
    MUNSON, B
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (04) : 786 - 789
  • [3] ANALYSIS OF PHENYLETHYLAMINES BY GAS-CHROMATOGRAPHY - CHEMICAL IONIZATION MASS-SPECTROMETRY
    EDWARDS, DJ
    DOSHI, PS
    HANIN, I
    [J]. ANALYTICAL BIOCHEMISTRY, 1979, 96 (02) : 308 - 316
  • [4] GAS-CHROMATOGRAPHY - MASS-SPECTROMETRY AND QUANTITATION OF IODOCOMPOUNDS
    CROSSLEY, DN
    RAMSDEN, DB
    HOFFENBERG, R
    [J]. ANNALES D ENDOCRINOLOGIE, 1978, 39 (05) : A11 - A11
  • [5] THE QUANTITATION OF TRIAZOLAM IN POSTMORTEM BLOOD BY GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY
    KOVES, G
    WELLS, J
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1986, 10 (06) : 241 - 244
  • [6] GAS-CHROMATOGRAPHY NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY OF INTACT GLUCURONIDES
    BROWN, SY
    GARLAND, WA
    FUKUDA, EK
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (01): : 32 - 36
  • [7] DETERMINATION OF CARPROFEN IN BLOOD BY GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY
    HODSHON, BJ
    GARLAND, WA
    PERRY, CW
    BADER, GJ
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (08): : 325 - 330
  • [8] DETERMINATION OF DAMINOZIDE IN APPLES BY GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY
    LIU, CH
    MATTERN, GC
    SINGER, GM
    ROSEN, JD
    [J]. JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1989, 72 (06): : 984 - 986
  • [9] DETERMINATION OF TERBUTALINE IN PLASMA BY GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY
    JACOBSSON, SE
    JONSSON, S
    LINDBERG, C
    SVENSSON, LA
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1980, 7 (06): : 265 - 268
  • [10] QUANTITATION OF A URINARY TETRASACCHARIDE BY GAS-CHROMATOGRAPHY AND MASS-SPECTROMETRY
    LENNARTSON, G
    LUNDBLAD, A
    SJOBLAD, S
    SVENSSON, S
    OCKERMAN, PA
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1976, 3 (02): : 51 - 54