Comparison of the efficacy between impedance-guided and contact force-guided atrial fibrillation ablation using an automated annotation system

被引:6
|
作者
Park, Hyoung-Seob [1 ]
Kim, In-Cheol [1 ]
Cho, Yun-Kyeong [1 ]
Yoon, Hyuck-Jun [1 ]
Kim, Hyungseop [1 ]
Nam, Chang-Wook [1 ]
Han, Seongwook [1 ]
Hur, Seung-Ho [1 ]
Kim, Yoon-Nyun [1 ]
Kim, Kwon-Bae [1 ]
机构
[1] Keimyung Univ, Dongsan Med Ctr, Div Cardiol, Daegu, South Korea
关键词
atrial fibrillation; catheter ablation; contact force; impedance; pulmonary vein;
D O I
10.1002/joa3.12054
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThis study compared the efficacy of catheter ablation of atrial fibrillation (AF) between impedance (IMP)-guided and contact force (CF)-guided annotation using the automated annotation system (VisiTag). MethodsFifty patients undergoing pulmonary vein isolation (PVI) for AF were randomized to the IMP-guided or CF-guided groups. The annotation criteria for VisiTag were a 10second minimum ablation time and 2mm maximum catheter movement range. A minimum CF of 10g was added to the criteria in the CF-guided group. In the IMP-guided group, a minimum IMP drop of over 5 was added to the criteria. ResultsThe rates of successful PVI after an initial ablation line were higher in the CF-guided group (80% vs 48%, P=.018). Although average CF was similar between two groups, the average force-time integral (FTI) was significantly higher in the CF-guided group (298.365. 2g<bold>s vs </bold>255.1 +/- 38.3g<bold>s</bold>, P=.007). The atrial arrhythmia-free survival at 1year demonstrated no difference between the two groups (84.0% in the IMP-guided group vs 80.0% in the CF-guided group, P=.737). If the use of any antiarrhythmic drug beyond the blanking period was considered as a failure, the clinical success rate at 1year was 52.0% for the CF-guided group vs 56.0% for the IMP-guided group (P=.813). ConclusionsAtrial fibrillation ablation using an automated annotation system guided by CF improved the success rate of PVI after the initial circumferential ablation. An IMP-guided annotation combined with catheter stability criteria showed similar clinical outcomes as compared to the CF-guided annotation.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [1] Comparison of myocardial injury and inflammation between ablation index-guided and conventional contact force-guided ablation in atrial fibrillation patients
    Yano, M.
    Egami, Y.
    Kawanami, S.
    Sugae, H.
    Ukita, K.
    Kawamura, A.
    Nakamura, H.
    Yasumoto, K.
    Tsuda, M.
    Okamoto, N.
    Matsunaga-Lee, Y.
    Nishino, M.
    Tanouchi, J.
    [J]. EUROPEAN HEART JOURNAL, 2023, 44
  • [2] Comparison of myocardial injury and inflammation between ablation index-guided and conventional contact force-guided ablation in atrial fibrillation patients
    Yano, Masamichi
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Nishino, Masami
    Tanouchi, Jun
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (09) : 2021 - 2030
  • [3] Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation
    Hisaki Makimoto
    Christian-H Heeger
    Tina Lin
    Andreas Rillig
    Andreas Metzner
    Erik Wissner
    Shibu Mathew
    Sebastian Deiss
    Peter Rausch
    Christine Lemeš
    Karl-Heinz Kuck
    Feifan Ouyang
    Roland Richard Tilz
    [J]. Clinical Research in Cardiology, 2015, 104 : 861 - 870
  • [4] Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation
    Makimoto, Hisaki
    Heeger, Christian-H
    Lin, Tina
    Rillig, Andreas
    Metzner, Andreas
    Wissner, Erik
    Mathew, Shibu
    Deiss, Sebastian
    Rausch, Peter
    Lemes, Christine
    Kuck, Karl-Heinz
    Ouyang, Feifan
    Tilz, Roland Richard
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (10) : 861 - 870
  • [5] Comparison of myocardial injury and inflammation between ablation index–guided and conventional contact force–guided ablation in atrial fibrillation patients
    Masamichi Yano
    Yasuyuki Egami
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masami Nishino
    Jun Tanouchi
    [J]. Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 2021 - 2030
  • [6] Clinical outcomes in patients with persistent atrial fibrillation after technologic advances including contact force-guided and ablation index-guided ablation
    Won Kyeong Jeon
    So-Ryoung Lee
    Eue-Keun Choi
    Seil Oh
    [J]. International Journal of Arrhythmia, 23 (1)
  • [7] Electrical reconnections after pulmonary vein isolation with or without contact force-guided catheters: a comparison of the proficiency of atrial fibrillation ablation
    Fujimoto, Y.
    Yodogawa, K.
    Iwasaki, Y.
    Hachisuka, M.
    Mimuro, R.
    Maru, Y.
    Oka, E.
    Hayashi, H.
    Yamamoto, T.
    Shimizu, W.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 1791 - 1791
  • [8] Contact force-guided catheter ablation for the treatment of atrial fibrillation: a meta-analysis of randomized, controlled trials
    Qi, Z.
    Luo, X.
    Wu, B.
    Shi, H.
    Jin, B.
    Wen, Z.
    [J]. BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2016, 49 (03)
  • [9] Cryoballoon or contact force-guided radiofrequency catheter ablation for persistent atrial fibrillation: Different strategies with similar results
    Hayase, Justin
    Buch, Eric
    [J]. HEART RHYTHM, 2018, 15 (12) : 1842 - 1843
  • [10] Role of contact force-guided radiofrequency catheter ablation for treatment of atrial fibrillation: A systematic review and meta-analysis
    Lin, Hui
    Chen, Yi-He
    Hou, Jian-Wen
    Lu, Zhao-Yang
    Xiang, Yin
    Li, Yi-Gang
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (09) : 994 - 1005