Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

被引:13
|
作者
Moon, Kyoung Ho [1 ]
Kang, Joon Soon [1 ]
Lee, Sang Hyup [1 ]
Jung, Sae Rom [1 ]
机构
[1] Inha Univ, Coll Med, Dept Orthoped Surg, Incheon, South Korea
关键词
Revision total hip arthroplasty; Extensively porous coated femoral stem;
D O I
10.4055/cios.2009.1.2.105
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty. Methods: This study reviewed the results of 35 patients who received a revision total hip arthroplasty with extensively porous coated femoral stem between August, 1996, and December, 2002. The mean follow-up period was 77.5 months. The clinical and radiological results were evaluated by the Harris hip score and serial roentgenographic fi ndings. Results: The preoperative and postoperative Harris hip score was 68.3 and 92.5, respectively. Radiographically, none of the acetabular components showed any evidence of migration, tilt, rotation, or shedding of metal particles. In addition, none of the femoral components showed evidence of subsidence, pedestal, or shedding of metal particles. Twenty-two hips had a mild stress shield and 2 hips had a moderate stress shield. The perioperative complications encountered were deep vein thrombosis (1 case), mild heterotopic ossifi cation (4 cases), intraoperative periprosthetic fractures (1 case), and nonunion of the trochanteric osteotomy site (2 cases). Conclusions: Extensively porous coated femoral stems and acetabular components produce excellent clinical and radiological results in revision total hip arthroplasty.
引用
收藏
页码:105 / 109
页数:5
相关论文
共 50 条
  • [1] Fracture of Extensively Porous-Coated Cylindrical Femoral Stem Following Revision Total Hip Arthroplasty
    Zhang Chao-Fan
    Yan Chun Hoi
    Ng Fu Yuen
    Chan Ping Keung
    Chiu Kwong Yuen
    [J]. 中华医学杂志(英文版), 2016, 129 (11) : 1374 - 1376
  • [2] Fracture of Extensively Porous-Coated Cylindrical Femoral Stem Following Revision Total Hip Arthroplasty
    Zhang, Chao-Fan
    Yan, Chun Hoi
    Ng, Fu Yuen
    Chan, Ping Keung
    Chiu, Kwong Yuen
    [J]. CHINESE MEDICAL JOURNAL, 2016, 129 (11) : 1374 - 1376
  • [3] Long-Term Results of Revision Total Hip Arthroplasty Using a Modern Extensively Porous-Coated Femoral Stem
    Wallace, Charles N.
    Chang, Justin S.
    Kayani, Babar
    Moriarty, Peter D.
    Tahmassebi, Jenni E.
    Haddad, Fares S.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (12): : 3697 - 3702
  • [4] Total hip arthroplasty - Concerns with extensively porous coated femoral components
    McAuley, JP
    Culpepper, WJ
    Engh, CA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) : 182 - 188
  • [5] Revision hip arthroplasty using an extensively porous coated stem: medium term results
    Jayakumar, Prakash
    Malik, Ahmad K.
    Islam, Saif U.
    Haddad, Fares S.
    [J]. HIP INTERNATIONAL, 2011, 21 (02) : 129 - 135
  • [6] Extensively porous-coated stems in femoral revision arthroplasty
    Paprosky, WG
    Weeden, SH
    [J]. ORTHOPEDICS, 2001, 24 (09) : 871 - 872
  • [7] Revision total hip arthroplasty using the Zweymuller femoral stem
    Oetgen M.E.
    Huo M.H.
    Keggi K.J.
    [J]. Journal of Orthopaedics and Traumatology, 2008, 9 (2) : 57 - 62
  • [8] Femoral component revision using extensively porous-coated cementless stem
    吴立东
    熊炎
    严世贵
    杨泉森
    戴雪松
    [J]. 中华创伤杂志(英文版), 2005, (06) : 358 - 363
  • [9] Femoral component revision using extensively porous-coated cementless stem
    吴立东
    熊炎
    严世贵
    杨泉森
    戴雪松
    [J]. ChineseJournalofTraumatology, 2005, (06) : 358 - 363
  • [10] Revision total hip arthroplasty after removal of a fractured well-fixed extensively porous-coated femoral component using a trephine
    Amanatullah, D. F.
    Siman, H.
    Pallante, G. D.
    Haber, D. B.
    Sierra, R. J.
    Trousdale, R. T.