THE RELATIONSHIPS BETWEEN CASUAL AND AMBULATORY BLOOD-PRESSURE MEASUREMENTS AND CENTRAL HEMODYNAMICS IN ESSENTIAL HUMAN HYPERTENSION

被引:0
|
作者
WHITE, WB
LUNDJOHANSEN, P
WEISS, S
OMVIK, P
INDURKHYA, N
机构
[1] UNIV BERGEN, CARDIOL SECT, BERGEN, NORWAY
[2] RUTGERS STATE UNIV, DEPT COMP SCI, NEW BRUNSWICK, NJ 08903 USA
关键词
AMBULATORY BLOOD PRESSURE; BLOOD PRESSURE LOAD; CENTRAL HEMODYNAMICS; AREA UNDER THE BLOOD PRESSURE CURVE; DATA ANALYSIS;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To determine the association between ambulatory blood pressure (ABP) and central hemodynamics in hypertensive patients and between the area under the 24-h blood pressure curve and the hemodynamic indexes. Patient population: Forty untreated essential hypertensive patients (28 previously untreated, 12 withdrawn from therapy for >12 weeks). Methods: Patients underwent casual and 24-h ABP monitoring and invasive measurements of central hemodynamics. Central measures of ABP included 24-h mean, awake, and sleep values guided by activity journals. The ABP data were modeled by Fourier series and the ability of the smoothed and unsmoothed data to predict hemodynamics was compared. Individual blood pressure curves were analyzed by calculating the area under the curve using different threshold awake and sleep values to test the correlations between this form of blood pressure load and hemodynamics. Results: Hemodynamic measures were not predicted by casual blood pressure but were related to ABP. Total peripheral resistance was strongly predicted by the area under the diastolic blood pressure (DBP) curve using an awake threshold of 90 mmHg and a sleep threshold of 80 mmHg (r=0.56, P<0.001). Data smoothing using Fourier transformation did not after any correlations between ABP and hemodynamics. Exercise stroke index, an indicator of cardiac function impaired in early hypertensive heart disease, was also best predicted by area under the DBP curve using the same thresholds as above (r=-0.56, P<0.001). Conclusions: These data imply that integrated areas under the ABP curve are related to hemodynamic hypertensive indexes and could be used to assess the extent of hypertensive burden in clinical trials.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 50 条
  • [1] BLOOD-PRESSURE DETERMINANTS OF CENTRAL HEMODYNAMICS IN ESSENTIAL HUMAN HYPERTENSION
    WHITE, WB
    LUNDJOHANSEN, P
    WEISS, S
    INDURKHYA, N
    OMVIK, P
    [J]. CIRCULATION, 1990, 82 (04) : 164 - 164
  • [2] THE RELATIONSHIP BETWEEN CASUAL AND AMBULATORY BLOOD-PRESSURE IN ESSENTIAL-HYPERTENSION - THE INFLUENCE OF WORK, DURATION OF HYPERTENSION AND ANTIHYPERTENSIVE TREATMENT
    EISKJAER, H
    PEDERSEN, EB
    [J]. JOURNAL OF INTERNAL MEDICINE, 1989, 225 (03) : 165 - 172
  • [3] EFFECT OF FLOSEQUINAN ON AMBULATORY BLOOD-PRESSURE AND RENAL HEMODYNAMICS IN ESSENTIAL-HYPERTENSION
    DUPONT, AG
    DEMEIRLEIR, K
    SCHOORS, DF
    SIX, RO
    [J]. CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1989, 46 (03): : 423 - 430
  • [4] CONTINUOUS AMBULATORY BLOOD-PRESSURE MONITORING VERSUS CASUAL BLOOD-PRESSURE IN BORDERLINE HYPERTENSION
    PESSINA, AC
    PALATINI, P
    DIMARCO, A
    MORMINO, P
    FAZIO, G
    LIBARDONI, M
    MOS, L
    CASIGLIA, E
    DALPALU, C
    [J]. JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1986, 8 : S93 - S97
  • [5] VARIABILITY OF DIRECT ARTERIAL BLOOD-PRESSURE IN ESSENTIAL-HYPERTENSION - RELATIONSHIPS BETWEEN THE FALL OF BLOOD-PRESSURE DURING SLEEP AND ECHOCARDIOGRAPHIC HEMODYNAMICS
    TAKAGI, N
    TOCHIKUBO, O
    ODA, H
    MIYAZAKI, N
    KANEKO, Y
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1984, 48 (08): : 944 - 944
  • [6] MICROALBUMINURIA AND CASUAL AND AMBULATORY BLOOD-PRESSURE MONITORING IN NORMOTENSIVES AND IN PATIENTS WITH BORDERLINE AND MILD ESSENTIAL-HYPERTENSION
    GIACONI, S
    LEVANTI, C
    FOMMEI, E
    INNOCENTI, F
    SEGHIERI, G
    PALLA, L
    PALOMBO, C
    GHIONE, S
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1989, 2 (04) : 259 - 261
  • [7] BISOPROLOL AND ATENOLOL IN ESSENTIAL-HYPERTENSION - EFFECTS ON SYSTEMIC AND RENAL HEMODYNAMICS AND ON AMBULATORY BLOOD-PRESSURE
    LEEMAN, M
    VANDEBORNE, P
    COLLART, F
    VANDENHOVEN, G
    PEETERS, L
    MELOT, C
    DEGAUTE, JP
    [J]. JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1993, 22 (06) : 785 - 791
  • [8] EVALUATION OF SLOW RELEASE NICARDIPINE IN ESSENTIAL-HYPERTENSION BY CASUAL AND AMBULATORY BLOOD-PRESSURE MEASUREMENTS - EFFECTS OF ACUTE VERSUS CHRONIC ADMINISTRATION
    BELLET, M
    PAGNY, JY
    CHATELLIER, G
    CORVOL, P
    MENARD, J
    [J]. JOURNAL OF HYPERTENSION, 1987, 5 (05) : 599 - 604
  • [9] Reproducibility of ambulatory blood pressure measurements in essential hypertension
    Zakopoulos, NA
    Nanas, SN
    Lekakis, JP
    Vemmos, KN
    Kotsis, VT
    Pitiriga, VC
    Stamatelopoulos, SF
    Moulopoulos, SD
    [J]. BLOOD PRESSURE MONITORING, 2001, 6 (01) : 41 - 45
  • [10] AMBULATORY BLOOD-PRESSURE VERSUS CASUAL PRESSURE FOR THE EVALUATION OF TARGET ORGAN DAMAGE IN HYPERTENSION - COMPLICATIONS OF HYPERTENSION
    PALATINI, P
    MORMINO, P
    DIMARCO, A
    LIBARDONI, M
    MOS, L
    MUNARI, L
    PESSINA, AC
    DALPALU, C
    [J]. JOURNAL OF HYPERTENSION, 1985, 3 : S425 - S427