VALIDATION OF CLOSED-LOOP SUBCUTANEOUS INSULIN INFUSION ALGORITHM - APPLICATION OF SUBCUTANEOUS INSULIN ABSORPTION KINETICS

被引:0
|
作者
ASAKAWA, N [1 ]
SAITO, Y [1 ]
YAMASAKI, Y [1 ]
KAWAMORI, R [1 ]
SHICHIRI, M [1 ]
机构
[1] OSAKA UNIV,SCH MED,DEPT MED 1,1-1-50 FUKUSHIMA,FUKUSHIMA KU,OSAKA 553,JAPAN
来源
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:193 / 198
页数:6
相关论文
共 50 条
  • [1] SUBCUTANEOUS INSULIN INFUSION WITH A CLOSED-LOOP GLYCEMIC CONTROL-SYSTEM
    KAWAMORI, R
    SHICHIRI, M
    ASAKAWA, N
    IWAMA, N
    ABE, H
    [J]. DIABETOLOGIA, 1983, 25 (02) : 170 - 170
  • [2] Closed-loop subcutaneous insulin delivery based on subcutaneous glucose sensing in adults
    Rebrin, K
    Steil, GM
    Panteleon, AE
    Hariri, F
    Darwin, C
    Saad, MF
    [J]. DIABETOLOGIA, 2004, 47 : A93 - A93
  • [3] Development of closed-loop intraperitoneal insulin infusion algorithm
    Nishida, K
    Sakakida, M
    Shimoda, S
    Matuo, Y
    Araki, E
    [J]. DIABETOLOGIA, 2001, 44 : A45 - A45
  • [4] CONTINUOUS SUBCUTANEOUS INSULIN INFUSION OR SUBCUTANEOUS INSULIN INJECTIONS
    TURNER, RC
    WARD, EA
    PHILLIPS, MA
    DORNAN, TL
    WARD, GM
    HOCKADAY, TDR
    [J]. LANCET, 1979, 2 (8140): : 481 - 481
  • [5] FAILURE OF CLOSED-LOOP ARTIFICIAL PANCREAS TO PREDICT OPTIMAL DOSE OF SUBCUTANEOUS INSULIN
    WEISBERG, GW
    SIEGELMAN, CA
    HORWITZ, DL
    [J]. CLINICAL RESEARCH, 1980, 28 (04): : A742 - A742
  • [6] FAILURE OF CLOSED-LOOP ARTIFICIAL PANCREAS TO PREDICT OPTIMAL DOSE OF SUBCUTANEOUS INSULIN
    WEISBERG, GW
    SIEGELMAN, CA
    HORWITZ, DL
    [J]. CLINICAL RESEARCH, 1981, 29 (02): : A426 - A426
  • [7] Insulin Estimation and Prediction A REVIEW OF THE ESTIMATION AND PREDICTION OF SUBCUTANEOUS INSULIN PHARMACOKINETICS IN CLOSED-LOOP GLUCOSE CONTROL
    Bondia, Jorge
    Romero-Vivo, Sergio
    Ricarte, Beatriz
    Luis Diez, Jose
    [J]. IEEE CONTROL SYSTEMS MAGAZINE, 2018, 38 (01): : 47 - 66
  • [8] Absorption kinetics of insulin after subcutaneous administration
    Soeborg, Tue
    Rasmussen, Christian Hove
    Mosekilde, Erik
    Colding-Jorgensen, Morten
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 36 (01) : 78 - 90
  • [9] Closed-loop blood-glucose control using dual subcutaneous infusion of insulin and glucagon in ambulatory diabetic pigs
    El-Khatib, Firas H.
    Jiang, John
    Damiano, Edward R.
    [J]. DIABETES, 2008, 57 : A23 - A23
  • [10] Closed-Loop Blood Glucose Control Using Dual Subcutaneous Infusion of Insulin and Glucagon Based on Switching PID Controller
    Gao, Xiaoteng
    Wang, Youqing
    [J]. PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 5023 - 5029