首页
学术期刊
论文检测
AIGC检测
热点
更多
数据
ELECTROCHROMATOGRAPHY WITH CONTINUOUS SAMPLE INTRODUCTION
被引:25
|
作者
:
TSUDA, T
论文数:
0
引用数:
0
h-index:
0
机构:
Nagoya Institute of Technology, Showa-ku, Nagoya, 466, Gokiso-cho
TSUDA, T
MURAMATSU, Y
论文数:
0
引用数:
0
h-index:
0
机构:
Nagoya Institute of Technology, Showa-ku, Nagoya, 466, Gokiso-cho
MURAMATSU, Y
机构
:
[1]
Nagoya Institute of Technology, Showa-ku, Nagoya, 466, Gokiso-cho
来源
:
JOURNAL OF CHROMATOGRAPHY
|
1990年
/ 515卷
关键词
:
D O I
:
10.1016/S0021-9673(01)89365-1
中图分类号
:
O65 [分析化学];
学科分类号
:
070302 ;
081704 ;
摘要
:
The flow profile and height equivalent to a theoretical plate in electromatography are discussed. Apparatus for continuous injection is proposed. Continuous injection of sample onto the column was accomplished for a period of up to 5 min, and charged solutes were in the column. Typical examples are presented. © 1990.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
[1]
BASIS OF SELECTIVITY IN CHROMATOGRAPHY, ELECTROCHROMATOGRAPHY, AND CONTINUOUS ELECTROCHROMATOGRAPHY
STRAIN, HH
论文数:
0
引用数:
0
h-index:
0
STRAIN, HH
ANALYTICAL CHEMISTRY,
1961,
33
(12)
: 1733
-
&
[2]
SEPARATIONS BY CONTINUOUS ELECTROCHROMATOGRAPHY
KARLER, A
论文数:
0
引用数:
0
h-index:
0
KARLER, A
ANALYTICAL CHEMISTRY,
1959,
31
(05)
: 848
-
851
[3]
APPARATUS FOR CONTINUOUS ELECTROCHROMATOGRAPHY
STRAIN, HH
论文数:
0
引用数:
0
h-index:
0
STRAIN, HH
ANALYTICAL CHEMISTRY,
1958,
30
(02)
: 228
-
231
[4]
APPARATUS FOR CONTINUOUS ELECTROCHROMATOGRAPHY
SATO, TR
论文数:
0
引用数:
0
h-index:
0
SATO, TR
NORRIS, WP
论文数:
0
引用数:
0
h-index:
0
NORRIS, WP
STRAIN, HH
论文数:
0
引用数:
0
h-index:
0
STRAIN, HH
ANALYTICAL CHEMISTRY,
1952,
24
(05)
: 776
-
778
[5]
A DEMONSTRATION OF CONTINUOUS ELECTROCHROMATOGRAPHY AND ELECTROPHORESIS
ZWEIG, G
论文数:
0
引用数:
0
h-index:
0
ZWEIG, G
JOURNAL OF CHROMATOGRAPHY,
1959,
2
(02):
: 202
-
203
[6]
Influence of sample plug width in capillary electrochromatography
Pyell, U
论文数:
0
引用数:
0
h-index:
0
机构:
Fachbereich Chemie, Philipps-Universität Marburg, D-35032 Marburg, Hans-Meerwein-Strasse
Pyell, U
Rebscher, H
论文数:
0
引用数:
0
h-index:
0
机构:
Fachbereich Chemie, Philipps-Universität Marburg, D-35032 Marburg, Hans-Meerwein-Strasse
Rebscher, H
Banholczer, A
论文数:
0
引用数:
0
h-index:
0
机构:
Fachbereich Chemie, Philipps-Universität Marburg, D-35032 Marburg, Hans-Meerwein-Strasse
Banholczer, A
JOURNAL OF CHROMATOGRAPHY A,
1997,
779
(1-2)
: 155
-
163
[7]
The development of a compact microfluidic chip analyzer with continuous sample introduction
Xu, ZR
论文数:
0
引用数:
0
h-index:
0
机构:
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Xu, ZR
Wang, SL
论文数:
0
引用数:
0
h-index:
0
机构:
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Wang, SL
Fan, XF
论文数:
0
引用数:
0
h-index:
0
机构:
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Fan, XF
Wang, FR
论文数:
0
引用数:
0
h-index:
0
机构:
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Wang, FR
Fang, ZL
论文数:
0
引用数:
0
h-index:
0
机构:
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
Fang, ZL
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,
2003,
31
(12)
: 1527
-
1530
[8]
CONTINUOUS ELECTROCHROMATOGRAPHY ON ION-EXCHANGE MEMBRANES
CAPLAN, SR
论文数:
0
引用数:
0
h-index:
0
CAPLAN, SR
JOURNAL OF THE ELECTROCHEMICAL SOCIETY,
1961,
108
(06)
: 577
-
585
[9]
SYNERGIC METHOD OF CARRYING OUT CONTINUOUS ELECTROCHROMATOGRAPHY
CAPLAN, SR
论文数:
0
引用数:
0
h-index:
0
CAPLAN, SR
NATURE,
1960,
185
(4710)
: 378
-
379
[10]
CONTINUOUS ELECTROCHROMATOGRAPHY USING A ROTATING ANNULAR SYSTEM
SCOTT, CD
论文数:
0
引用数:
0
h-index:
0
机构:
Oak Ridge Natl Lab, Oak Ridge, TN,, USA, Oak Ridge Natl Lab, Oak Ridge, TN, USA
SCOTT, CD
SEPARATION SCIENCE AND TECHNOLOGY,
1986,
21
(09)
: 905
-
917
←
1
2
3
4
5
→