A CW 4-ROD RFQ LINAC

被引:13
|
作者
FUJISAWA, H [1 ]
机构
[1] KYOTO UNIV,INST CHEM RES,ACCELERATOR LAB,UJI,KYOTO 611,JAPAN
关键词
D O I
10.1016/0168-9002(94)90968-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cw 4-rod RFQ linac system has been designed, constructed, and tested as an accelerator section of a MeV-class ion implanter system. The tank diameter is only 60 cm for 34 MHz operating frequency. An equally spaced arrangement of the RFQ electrode supporting plates is proved to be suitable for a low resonant frequency 4-rod RFQ structure. The RFQ electrode cross section is not circular but rectangular to make the handling and maintenance of the electrodes easier. The machining of the electrode is done three dimensionally. Second order corrections in the analyzing magnet of the LEBT (Low Energy Beam Transport) section assure a better transmission through and the matching to the RFQ. A new approach is introduced to measure the rf characteristics of the 4-rod RFQ. This method requires only a few capacitors and a network analyzer. Both the rf and thermal stability of the 4-rod RFQ are tested up to cw 50 kW. Beam experiments with several ions confirm the acceleration of beams to the goal energy of 83 keV/u. The ion beam intensities obtained at the RFQ output for He+, N2+, and C+ are 32, 13, and 220 pmuA, respectively. The measured beam transmissions of > 80% agree with the PARMTEQ calculations. The ion implantation method also gives definitive information on the energies of an RFQ output beam.
引用
收藏
页码:23 / 42
页数:20
相关论文
共 50 条
  • [1] STUDY OF A 4-ROD RFQ STRUCTURE AT 470 MHZ
    KAZIMI, R
    HUSON, FR
    MACKAY, WW
    NASSIRI, A
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 990 - 992
  • [2] 4 ROD RFQ INJECTORS FOR THE GSI LINAC
    SCHEMPP, A
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1093 - 1097
  • [3] Longitudinal electrode voltage distribution on a 4-rod RFQ simulation model
    Fischer, P.
    Mueller, N.
    Schempp, A.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 1981 - 1982
  • [4] Study on shunt impedance and voltage distribution of 4-rod RFQ cavity
    Zang Zhou-Li
    Jameson, R. A.
    Zhao Hong-Wei
    Xu Zhe
    Zhang Sheng-Hu
    Zhang Cong
    Sun Lie-Peng
    Mei Li-Rong
    Shen Xiao-Kang
    CHINESE PHYSICS C, 2010, 34 (03) : 398 - 401
  • [5] Study on shunt impedance and voltage distribution of 4-rod RFQ cavity
    张周礼
    R.A. Jameson
    赵红卫
    许哲
    张生虎
    张聪
    孙列鹏
    梅立荣
    申晓康
    中国物理C, 2010, 34 (03) : 398 - 401
  • [6] Simulation of the triumf split-ring 4-rod RFQ with mafia
    Bricault, PG
    Schneider, HR
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1125 - 1127
  • [7] Design and simulation of a cooling system for the high current 4-rod RFQ cavity
    Zhu, K
    Guo, ZY
    Fang, JX
    Guo, JF
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (08): : 797 - 801
  • [8] ACCELERATION OF INTENSE PROTON-BEAM WITH SPLIT COAXIAL 4-ROD RFQ
    LEIPE, P
    LANGBEIN, K
    DEITINGHOF, H
    KLEIN, H
    SCHEMPP, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (01): : 213 - 219
  • [9] Modal response of 4-rod type radio frequency quadrupole linac
    Chatterjee, Avik
    Mahapatra, Abhijit
    Mondal, Manas
    Chakrabarti, Alok
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (10):
  • [10] Mechanical vibration analysis of the 4-rod RFQ at the high charge state injector at GSI
    Koser, D.
    Gerhard, P.
    Podlech, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 917 : 47 - 55