HPLC DETERMINATION OF MORPHINE HYDROMORPHONE BUPIVACAINE AND MORPHINE HYDROMORPHONE TETRACAINE MIXTURES IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION

被引:12
|
作者
VENKATESHWARAN, TG
STEWART, JT
机构
[1] Department of Medicinal Chemistry, College of Pharmacy, The University of Georgia, Athens
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1995年 / 18卷 / 03期
关键词
D O I
10.1080/10826079508009257
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High performance liquid chromatography procedures have been developed for the assay of morphine-hydromorphone-bupivacaine and morphine-hydromorphone-tetracaine mixtures in 0.9% sodium chloride injection. The separation and quantitation of morphine-hydromorphone-bupivacaine was performed on a phenyl column at ambient temperature using a mobile phase of 50:50 v/v 0.02M phosphate buffer pH 6.0-acetonitrile at a flow rate of 1.0 mL/min with the detection of all three analytes at 235 nm. The separation was achieved within 20 min with sensitivity in ng/mL range for each analyte. Morphine, hydromorphone and bupivacaine were linear in 5.0-51, 5.1-51.7 and 5.0-50 mu g/mL ranges, respectively. Accuracy and precision were in the range 0.51-1.89 and 0.02-0.50%, respectively, for all three analytes and the limit of detection was close to 250 ng/mL for each component based on a signal to noise ratio of 3 and 20 mu L injection. The separation and quantitation of morphine-hydromorphone-tetracaine was achieved on a silica column at ambient temperature using a mobile phase of 75:25 v/v 0.01 M phosphate buffer, pH 4.0-methanol at a flow rate of 1.0 mL/min with detection of the three analytes at 235 nm. The separation was achieved within 20 min with sensitivity in the ng/mL range for each analyte. Morphine, hydromorphone and tetracaine were linear in the 4.95-49.6, 5.07-50.69 and 5.0-50.17 mu g/mL ranges, respectively. Accuracy and precision were in the range 0.07-2.93% and 0.01-0.40%, respectively, for each analyte. The limit of detection was near 330 ng/mL for each compound and was based on a signal to noise ratio of 3 and a 20 mu L injection.
引用
收藏
页码:565 / 578
页数:14
相关论文
共 50 条
  • [1] HPLC determination of morphine-hydromorphone-bupivacaine and morphine-hydromorphone-tetracaine mixtures in 0.9% sodium chloride injection
    Venkateshwaran, T.G.
    Stewart, J.T.
    Journal of Liquid Chromatography, 1995, 18 (03):
  • [2] HPLC DETERMINATION OF A METOCLOPRAMIDE AND ONDANSETRON MIXTURE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    VENKATESHWARAN, TG
    KING, DT
    STEWART, JT
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (01): : 117 - 126
  • [3] COMPATIBILITY OF MAGNESIUM-SULFATE AND MORPHINE-SULFATE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    VOGT, C
    SKIPPER, PM
    RUGGABER, S
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (11): : 2311 - 2311
  • [4] HPLC DETERMINATION OF A VINCRISTINE, DOXORUBICIN, AND ONDANSETRON MIXTURE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    KING, DT
    VENKATESHWARAN, TG
    STEWART, JT
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (06): : 1399 - 1411
  • [5] HPLC DETERMINATION OF ONDANSETRON-ATROPINE AND ONDANSETRON-GLYCOPYRROLATE MIXTURES IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    VENKATESHWARAN, TG
    KING, DT
    STEWART, JT
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (13): : 2647 - 2659
  • [6] STABILITY OF FOSCARNET SODIUM IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    WOODS, K
    STEINMANN, W
    BRUNS, L
    NEELS, JT
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1994, 51 (01): : 88 - 90
  • [7] STABILITY OF MORPHINE-SULFATE IN BACTERIOSTATIC 0.9-PERCENT SODIUM-CHLORIDE INJECTION STORED IN GLASS VIALS AT 2 TEMPERATURES
    NAHATA, MC
    MOROSCO, RS
    HIPPLE, TF
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1992, 49 (11): : 2785 - 2786
  • [8] STABILITY OF PHENOBARBITAL SODIUM DILUTED IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    NAHATA, MC
    HIPPLE, TF
    STRAUSBAUGH, SD
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1986, 43 (02): : 384 - 385
  • [9] COMPATIBILITY OF CISPLATIN AND FLUOROURACIL IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION
    STEWART, CF
    FLEMING, RA
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1990, 47 (06): : 1373 - 1377
  • [10] COMPATIBILITY AND STABILITY OF ONDANSETRON HYDROCHLORIDE WITH MORPHINE-SULFATE AND WITH HYDROMORPHONE HYDROCHLORIDE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION AT 4-DEGREES-C, 22-DEGREES-C, AND 32-DEGREES-C
    TRISSEL, LA
    XU, QY
    MARTINEZ, JF
    FOX, JL
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1994, 51 (17): : 2138 - 2142